MXD Users Manual
April 5, 2012
Page 16 of 26
5.
If PHB codes are to be programmed into Group 3, press the HELP button again. The base unit
will announce,
“
Program Personal Help Buttons Group 3.”
6.
Program PHB codes into Group 3 by following steps 3 through 6 in the instructions for
programming PHBs into Group 1.
7.
If PHB codes are to be programmed into Group 4, press the HELP button again. The base unit
will announce,
“
Program Personal Help Buttons Group 4.”
8.
Program PHB codes into Group 4 by following steps 3 through 6 in the instructions for
programming PHBs into Group 1.
9.
After all PHBs are programmed into the desired groups, press the RESET button one time. The
MXD will announce, “System Ready.” This completes the programming sequence, and each of
the PHBs recorded in Group 1 should now be recognized by the unit.
10.
Test all PHBs by pressing their buttons and the unit to call the response center.
11.
If each test call is successful, the PHB is ready for service. Reprogram any PHBs into the desired
group that do not activate the base station when pushed.
To program a Medication Dispenser Code into the MXD:
The MXD unit can be programmed to
recognize up to two Mytrex approved medication dispensers that have been equipped for monitoring by
Mytrex equipment. Perform the following steps:
1.
With the unit turned on, press and release the T/L button on the rear of your base unit. The base
unit will announce, “RANGE TEST MODE.”
2.
Press and release the base unit HELP button one time. The base unit will announce, “Program
Personal Help Buttons.”
3.
Press and release the T/L button again. The base unit will announce, “Program Medication
Dispenser Group 1.”
4.
Hold the medication dispenser battery compartment door in one hand. Press and hold the small
button located on the transmitter inside the medication dispenser. After two to three seconds, the
base unit will sound a steady tone for about one second, pause for two seconds, and then sound
the steady tone for another second. The unit will repeat this sequence every three seconds until
the button is released. This is the signal that the unit has been programmed to recognize the
medication dispenser's code.
5.
After at least one tone is received, release the button on the medication dispenser transmitter.
If another medication dispenser needs to be programmed to the MXD base unit, push the HELP button
one time. The base unit will announce,
“
Program Medication Dispenser Group 2.
”
7.
Using the second medication dispenser, repeat steps 4 and 5.
8.
When up to two medication dispensers have been programmed, press and release the RESET
button to return the unit to normal operation. The MXD will announce, “System Ready.”
9.
Initiate a test call for each medication dispenser by holding the battery compartment door open
and pressing and releasing the small button located on the transmitter inside the dispenser. The
MXD should detect the medication dispenser signal and initiate a call to the response center.
10.
Important:
Verify with the response center attendant that he/she received a medication
dispenser signal, not a PHB signal.
11.
If each medication dispenser test is successful, the medication dispenser can be placed in service
in accordance with the dispenser’s instructions.
Provisions for Supervisory Personal Help Buttons, Smoke Detectors and Carbon
Monoxide Monitors (not currently available)
The manufacturer has incorporated code groups for up to eight supervisory devices, eight smoke detectors
and eight carbon monoxide (CO) detectors into the MXD unit. Each group can remember one device