Setup: Connections:
7
The DDD-603 meter is capable of reading both AES/EBU and S/PDIF signals. Two
XLR connectors on the back of the unit are wired according to AES/EBU specs and
an adaptor described below should be used for S/PDIF signals. The meter input is
high impedance with minimal effect on the clock jitter. We found this type of in/out
superior to a regular 110 Ohm buffered in/out. In most situations the meter can be
daisy-chained, but in jitter critical applications (such as DAC inputs) it should be
connected at the end of the signal chain. The DDD-603 input/output is wired as
below:
The DDD-603 meter requires reg5V supply with min. of 1.5A capacity.
Every meter is supplied with such a power adaptor. Using different power supply
may
damage the unit and voids warranty.
S/PDIF adaptor
Power supply
Internal in/out wiring
2
3
1
2
3
1
digital input
high
impedance
meter input
+
_
digital throughput
1
3
2
XLR
RCA jack
GND
+5V (+/- 5%)
Additional features
and software versions:
"Basic" version V1.3
"Full mastering" version V3.3
The DDD-603 meter is software based. Mytek manufacures two versions of the
meter: "basic" - V1.3 and "full mastering" - V3.3. The features described previously
are "basic" features. "Full mastering" softvare V3.3
provides extra features which can be enabled by setting the DIP switch on the back
panel of the unit. The switch works only if software version V3.3 or higher is
installed (it is disabled in the "basic" version V1.3). Version V3.3 has also a
function selectable at the front panel. For additional cost owners of the
"basic" version can upgrade to "full" version by exchanging the internal custom
memory chip at your dealer or Mytek.
(except for the phase meter)
phase
meter
All basic features enabled (as in V1.3)
plus the phase
meter. Overs of 3 samples or more as in 1630.
Basic features,
The DIP switch is
disabled.
no phase meter.
Overs of 3 samples or more as in 1630.
V3.3- 7 segment display shows
. E means 10 or more. Use it
to determine how bad the overload is and to track overs.
The counter cannot be reset manually, it will reset itself
every time the over occurs.
number of samples
overloaded in last overshoot
V3.3- Overload led is lit if
. This feature as well as 4 and 5 can be used
when an "overload standard" other than
is used.
1 or more samples are
overloaded
Sony 1630
V3.2- Overload led is lit if
.
2 or more samples are
overloaded
V3.3- Overload led is lit if
.
4 or more samples are
overloaded
ON
1
4
3
5 6 7
2
OFF
ON
1
4
3
5 6 7
2
OFF
ON
1
4
3
5 6 7
2
OFF
ON
1
4
3
5 6 7
2
OFF
ON
1
4
3
5 6 7
2
OFF
ON
1
4
3
5 6 7
2
OFF
means either position
1
3
2
4
5
8