PROBLEM:
Pressure switch on pump head is bad.
SOLUTION:
Replace with new pressure switch.
SYMPTOM:
Vacuum motor not working properly.
PROBLEM:
Switch on switch plate is bad.
SOLUTION:
Replace switch.
PROBLEM:
Hose not connected tightly to wand or machine.
SOLUTION:
Connect hose tightly.
PROBLEM:
Wand is clogged with hair, carpet fibers and or debris.
SOLUTION:
Clean wand.
PROBLEM:
Drain valve is not shut completely.
SOLUTION:
Close drain valve completely.
PROBLEM:
Vacuum tank lid is not on tightly.
SOLUTION:
Secure the vacuum tank lid on tightly.
PROBLEM:
Vacuum tank lid or the vacuum tank is cracked.
SOLUTION:
Replace the vacuum tank lid or the vacuum tank.
PROBLEM:
Vacuum hose is cracked or split.
SOLUTION:
Replace vacuum hose.
PROBLEM:
Ball float is shut off.
SOLUTION:
Empty the vacuum tank of all wastewater.
PROBLEM:
Vacuum motor armature is worn out.
SOLUTION:
Replace vacuum motor.
PROBLEM:
Water is coming out of the vacuum motor.
SOLUTION:
Use a low foaming detergent.
PROBLEM:
Ball float is not installed correctly.
SOLUTION:
Make sure the ball float is firmly installed on the elbow.