TROUBLESHOOTING
SYMPTOM:
Unit will not turn on.
PROBLEM:
Not plugged in.
SOLUTION:
Plug machine in proper outlet.
PROBLEM:
Circuit breaker has popped.
SOLUTION:
Reset circuit breaker. Make sure no other items are running on the
same circuit as machine. Outlet must be a 20-amp circuit.
PROBLEM:
Wire from power cord has become disconnected from terminal
block.
SOLUTION:
Reattach wire to terminal block.
SYMPTOM:
Pump is not running properly.
PROBLEM:
Quick disconnects are not completely locked together.
SOLUTION:
Snap quick disconnects firmly together.
PROBLEM:
Switch on switch plate is bad.
SOLUTION: Replace
switch.
PROBLEM:
Jets on wand are clogged.
SOLUTION:
Clean jet with soft wire brush or remove jet and flush clean.
PROBLEM:
Filters are clogged.
SOLUTION:
Remove filters and rinse with clean water.
PROBLEM:
The solution tank is empty.
SOLUTION:
Fill the solution tank up with a premixed detergent.
PROBLEM:
Pump wire has become disconnected.
SOLUTION:
Reconnect wire.
PROBLEM:
Pump motor brushes are worn out.
SOLUTION:
Replace pump.
PROBLEM:
Pressure drops and pump pulsates and/or makes noise.
SOLUTION:
With pump running, and solution hose and cleaning tool attached,
depress priming button for 60 seconds.
PROBLEM:
Pump is pulsating.
SOLUTION:
Tighten all hoses. Check for leaks.