background image

8

ESCAPE™

 

ETM SWITCH PLATE AND POWER SOCKETS

Top Socket: Powers Vac 1, Vac 2 Pump, & Pump-out. 

 

Bottom Socket: Powers Vac 3 and Vac 4. 

Plug in to top socket to use vacuum 1 or 2, pump or pump-out. To use vacuum 3 or 4 plug in bottom socket. 

Top power socket 

Bottom power socket 

ESCAPE™ ETM

Содержание ESCAPE ETM

Страница 1: ...4 Please read before use Register your product at http www mytee com support register General Information p 2 Features p 7 Switchplate p 8 Power Options p 9 Operation p 10 Accessories p 12 Parts Prici...

Страница 2: ...a Mytee service personnel or Mytee authorized Service Center using Mytee original replacement parts and accessories for repairs are needing to be performed When and if calling Mytee for support pleas...

Страница 3: ...50Hz Machine Weight 200 lbs Machine Dimensions Without cart 32 x 21 25 x 36 With cart 43 x 21 25 x 44 25 Power Cord Dual twist lock 50 12 3 Operating Instructions POWER CORDS There are four basic ways...

Страница 4: ...should not take a lot of pressure to remove the switch so be careful not to break it 5 Place the rubber washer over the threads of the new switch and all the way down to the 13 16 nut side 6 Place a...

Страница 5: ...e Make sure not to lose any nuts or rubber washers in case they are needed in the future 8 On the new float switch hold the float switch finger all the way to one side by pushing on the opposite side...

Страница 6: ...6 watts not peak watts In any case check with the Generator manufacturer to ensure the unit can provide 30 amps at 230 volts continuously GENERAL INFORMATION...

Страница 7: ...ACK ESCAPE ETM FRONT ESCAPE ETM ACCESSORY ITEMS INCLUDED H107 Cuff Lynx 2 5 x 2 5 Hose Adapter 8 Recovery Tank Drain Valve 9 Pump Out 10 2 Male Cuff Lynx Inlet 11 PSI Gauge 1 Switch Plate 2 Prime Valv...

Страница 8: ...CKETS Top Socket Powers Vac 1 Vac 2 Pump Pump out Bottom Socket Powers Vac 3 and Vac 4 Plug in to top socket to use vacuum 1 or 2 pump or pump out To use vacuum 3 or 4 plug in bottom socket Top power...

Страница 9: ...xes plug each cord in to four separate 115 volt electrical legs ESCAPE ETM POWER OPTIONS 1 2 Plug each 50 power cord into the 3 or 4 prong electrical adaptor Once connected plug electrical adaptor int...

Страница 10: ...l decrease water pressure and turning to the right will increase water pressure Please refer to the Pressure Gauge to monitor your water pressure ESCAPE ETM Attach female end of a solution hose to a w...

Страница 11: ...Place the end of the hose in a location where dirty water can drain Using the recovery tank drain valve is also available ESCAPE ETM AUTO FILL SOLUTION TANK DUMP VALVE For a convienent way to fill up...

Страница 12: ...ea potentiometer slide 1 16 69 ea qd brass 1 4 m 1 8 49 ea filter in line 100 mesh 1 4 mpt x fpt 1 13 99 ea nipple hex 1 4 mpt x 1 8 mpt 2 7 99 ea valve flow 1 8 1 84 99 ea swivel high pressure stainl...

Страница 13: ...RIAL DIMENSIONS ARE IN INCHES TOLERANCES ANGULAR MACH 5 ONE PLACE DECIMAL 03 TWO PLACE DECIMAL 05 THREE PLACE DECIMAL 003 PROPRIETARY AND CONFIDENTIAL THE INFORMATION CONTAINED IN THIS DRAWING IS THE...

Страница 14: ...90 deg 1 2 barb x 3 8 mpt 1 9 49 ea 68 B105 bushing brass 3 8 mpt x 1 4 1 3 19 ea PART NO DESCRIPTION QTY MSRP A959 harness electrical 1 74 99 ea E351 power cord ext 50 12 3 twist lock 2 78 99 ea H106...

Страница 15: ...82 16 to sol tank to sol tank to PH634 11 10 to pressure gauge thru B130 55 to unloader thru B136 36 to flow meter thru B131 53 to 7qt bottle thru PH634 32 63 24 11 11 98 35 11 38 34 94 D C B A B C D...

Страница 16: ...ETM 12 2013 E SCALE 1 8 REV DWG NO C SIZE TITLE NAME DATE COMMENTS CHECKED DRAWN PROPRIETARY AND CONFIDENTIAL THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF MYTEE PRODUCTS INC ANY R...

Страница 17: ...Pump L2 L1 G Pump Out Pump Out L2 L1 G 230 Volts G X Y Cooling Fan N O Switch Twist lock Flanged Receptacle C 304 C 304 C 384A C 332 E 369 C 318 E 360 To Metal Plate To Metal Plate To Metal Plate To M...

Страница 18: ...VAC 4 L2 L1 G VAC 4 Twist Lock Flanged Receptacle 230 volts Ground Wire to metal faceplate C 304 C 304 E 360 N O E 373 L1 L2 G Cooling Fan C 318 VAC 3 230V Relays Float Switch L1 Electric Truck Mount...

Страница 19: ...esh Screen Air Flow Air Flow Air Flow Vac Control Boxes Each box controls 1 level switch Boxes should always be set to 230V Vacs 3 4 Cord 2 Mounted to cabinet top Vacs 1 2 Cord 1 Mounted to the tank w...

Страница 20: ...PE ETM HIGH PRESSURE PUMP SYSTEM High Pressure Pump System Inlet Hose Pressure Gauge Pressure Regulator Solution Quick Disconnect Filter In Tank Clean Regularly Bypass Hose To Tank High Pressure Low P...

Страница 21: ...ESCAPE ETM AUTO PUMP OUT SYSTEM Male Cam Fitting Auto Pump Out Pump Vacuum Hose Check Valve keeps vacuum from leaking through pump Auto Pump Out System Level Switch Controls pumps On O Clean regularl...

Страница 22: ...22 Mytee Products Inc 13655 Stowe Dr Poway CA 92064 www mytee com FX 858 679 7814 2017 Mytee Products Inc Printed in the U S A NOTES...