IDUM Official Manual
8
INSTALLATION
Follow the installation instructions carefully to avoid module or rack damage.
1. Ensure the power connection is disconnected before installing the device.
2. Identify 10HP of free rack space in which to install the module.
3. Connect the 10 pin connector from the IDC ribbon power cable to the header on the
rear side of the module by aligning correctly with the red stripe on the ribbon conductor
nearest to the -12V pin indicator on the header.
4. Insert the cable through the rack and connect the 16 pin side of the IDC ribbon cable to
the rack power supply header. Ensure that the pins are aligned correctly with the red
stripe on the ribbon conductor nearest to the -12V pin on the header.
5. Position the module into the dedicated rack position.
6. Attach the 4 x M3 screws by screwing into the 4 locator holes and the rack mount
taking care to not over tighten the screws.
7. Turn on the power to the rack.
8. The module will start up and be ready to use.
Ensure the following conditions are correct for trouble free installation.
•
Rack power supply can accommodate all of the installed modules total current ratings.
IDUM Power requirements are +12V 50mA, -12V 50mA, +5V Not Used.
•
Module power cable orientation is correct at both the rack and module side. Use the
module supplied IDC ribbon cable.
•
Ensure the rack earth / grounding is correct.
•
Take care to avoid patch cables falling into the rack or touching module PCB’s
Содержание IDUM
Страница 1: ......
Страница 2: ...2 2...
Страница 4: ...4 4...
Страница 6: ...6 6...
Страница 7: ...IDUM Official Manual 7...
Страница 18: ...18 18...
Страница 19: ...IDUM Official Manual 19...
Страница 29: ...IDUM Official Manual 29 USER NOTES...
Страница 30: ...30 30...
Страница 31: ...IDUM Official Manual 31...
Страница 38: ...IDUM Official Manual 38...