background image

05

KICKSPACE

®

 500 DUO ECO

6.0  Controls 

(continued...)

Operating Modes (continued...)

Function

Adjustment

Description

*When the mean water temperature is greater than 43°C the fan will switch on, then when the water temperature drops below 43°C the fan will switch off. 
Performance will depend on the water temperature and the flow though the coil.

**The product incorporates a 1kW electric heating element to provide heating when the central heating is not in operation. The electric element is controlled 
independently but cannot be used simultaneously with the central heating.

See previous page.

5.0

6.0

See following page for ‘Programme Mode’ setup.

Note: When in AUTO mode it is possible to override by 
selecting a new temperature. To do this while in AUTO mode, 
press (OK), the temperature will begin to blink, change the 
temperature using 

  or  

  and press (OK) to confirm.  

The

symbol will display showing the override and this will  

last for 2 hours. To remove the override you can press 

.

Note: To see the set temperature simply press 

 again.

Automatic Setting

The unit will run according to one of the 9 
preset timed programmes, or one of the 4 user 
defined programmes.

Auto

The display will show the ambient temperature.
Press (OK), set temperature will begin to blink.
Use 

  or  

 to adjust the required room temperature.

Press (OK) to confirm.
The ambient room temperature will then display.

Default s19°C
Max temp s19°C - night set back temperature can not 
be higher than comfort mode set point.
Min temp s5.5°C

Note: To see the set temperature simply press 

.

Night Set-back Setting

Provides room temperature controls for when 
the room is not occupied.

Holiday Function

Provides frost protection or overheat protection 
during periods of absence (holiday). 

•  For permanent frost protection select       and press (OK).    
 

  is shown in permanent frost protection.

•  For holiday frost protection press (OK) again, ‘no’ will blink.

Press  

 button to increase number of hours (1-24)/days (1-99), 

and press (OK) to confirm. Thermostat is now in holiday mode.
The  

  will blink and will continue to blink until the 

timer ends.
It is possible to exit the holiday function by pressing and  
holding 

 for 2 seconds.

Programme Menu

Provides choice from 9 pre-programmed and 
4 user defined timed programmes.

Refer to following page.

P

Boost Function

Brings the unit on irrespective of the 
programme or temperature setting for 
a predefined period.
Default is 30 minutes.
Can be used in Comfort, Auto, 
Night Set-Back mode.

Select       using 

  or  

 or directly using button 20. 

The time period in minutes will blink.
Use 

  or  

 to adjust time by increments of 10 minutes.

Press (OK) to confirm, the hourglass will begin to blink 
and countdown.
It is possible to exit boost function by pressing 

.

Comfort Mode continued...

Heating mode – Electric**
To enter this mode:
•  Set the fan only/off/heating switch  
  to heating (red dot)
•  Set the system selector switch to position II
•  Select the fan speed switch to position I
The unit will now run on low speed.
The element will not activate if the system  
water temperature is above 40°C. 

Содержание KICKSPACE 500 DUO

Страница 1: ...COMPLETE HEATING SOLUTIONS KICKSPACE 500 DUO ECO INSTALLATION OPERATING MANUAL PLEASE LEAVE THIS MANUAL WITH THE END USER...

Страница 2: ...sily accessible position adjacent to the unit If the supply cord to the KICKSPACE 500 DUO ECO is damaged it must be replaced by the manufacturer its service agent or similar qualified persons in order...

Страница 3: ...plinth and bring the KICKSPACE forward into the opening so the front edge projects approximately 10mm through the plinth l KICKSPACE DUO ECO is fitted with a transit cover to protect the electric elem...

Страница 4: ...begin to blink 8 Use or to change the year and press OK to confirm and then scrolll or to go back to the main menu Operating Modes Use and keys to choose from the following parameters A function is se...

Страница 5: ...back temperature can not be higher than comfort mode set point Min temp setting 5 5 C Note To see the set temperature simply press Night Set back Setting Provides room temperature controls for when t...

Страница 6: ...programme P1 P9 4 Press OK to confirm the chosen programme User Programme Menu 1 Select P by pressing until ProG is displayed 2 Press OK twice and the programme number will begin to blink 3 Use or to...

Страница 7: ...speed to required setting KICKSPACE may have poor performance cycle if a low water temperature flow rate is supplied please refer to your installer as this could be from the following Unit incorrectl...

Страница 8: ...T40 T50 T60 500 DUO ECO Normal 393 566 733 896 1056 1340 1930 2501 3057 3603 Boost 447 683 923 1166 1412 1524 2331 3150 3980 4817 Heat Output Watts Heat Output Btu h Temperature Difference C Fan Speed...

Страница 9: ...d 10 Set temperature or room temp Hour and date during adjustment time of boost period 11 Behaviour indicator 3 led colours green orange and red visible through the plastic 12 Open window detection 13...

Страница 10: ...10 KICKSPACE 500 DUO ECO 8 0 Appendix continued Fig 7 Fitting instructions 1 3 2 OK Fig 8...

Страница 11: ...feedback N A electronic heat charge control with room and or outdoor temperature feedback N A fan assisted heat output N A Type of heat output room temperature control single stage heat output and no...

Страница 12: ...Product code and serial number location Product Serial Number COMPLETE HEATING SOLUTIONS 01 09 18...