05
KICKSPACE
®
500 DUO ECO
6.0 Controls
(continued...)
Operating Modes (continued...)
Function
Adjustment
Description
*When the mean water temperature is greater than 43°C the fan will switch on, then when the water temperature drops below 43°C the fan will switch off.
Performance will depend on the water temperature and the flow though the coil.
**The product incorporates a 1kW electric heating element to provide heating when the central heating is not in operation. The electric element is controlled
independently but cannot be used simultaneously with the central heating.
See previous page.
5.0
6.0
See following page for ‘Programme Mode’ setup.
Note: When in AUTO mode it is possible to override by
selecting a new temperature. To do this while in AUTO mode,
press (OK), the temperature will begin to blink, change the
temperature using
or
and press (OK) to confirm.
The
symbol will display showing the override and this will
last for 2 hours. To remove the override you can press
.
Note: To see the set temperature simply press
again.
Automatic Setting
The unit will run according to one of the 9
preset timed programmes, or one of the 4 user
defined programmes.
Auto
The display will show the ambient temperature.
Press (OK), set temperature will begin to blink.
Use
or
to adjust the required room temperature.
Press (OK) to confirm.
The ambient room temperature will then display.
Default s19°C
Max temp s19°C - night set back temperature can not
be higher than comfort mode set point.
Min temp s5.5°C
Note: To see the set temperature simply press
.
Night Set-back Setting
Provides room temperature controls for when
the room is not occupied.
Holiday Function
Provides frost protection or overheat protection
during periods of absence (holiday).
• For permanent frost protection select and press (OK).
is shown in permanent frost protection.
• For holiday frost protection press (OK) again, ‘no’ will blink.
Press
button to increase number of hours (1-24)/days (1-99),
and press (OK) to confirm. Thermostat is now in holiday mode.
The
will blink and will continue to blink until the
timer ends.
It is possible to exit the holiday function by pressing and
holding
for 2 seconds.
Programme Menu
Provides choice from 9 pre-programmed and
4 user defined timed programmes.
Refer to following page.
P
Boost Function
Brings the unit on irrespective of the
programme or temperature setting for
a predefined period.
Default is 30 minutes.
Can be used in Comfort, Auto,
Night Set-Back mode.
Select using
or
or directly using button 20.
The time period in minutes will blink.
Use
or
to adjust time by increments of 10 minutes.
Press (OK) to confirm, the hourglass will begin to blink
and countdown.
It is possible to exit boost function by pressing
.
Comfort Mode continued...
Heating mode – Electric**
To enter this mode:
• Set the fan only/off/heating switch
to heating (red dot)
• Set the system selector switch to position II
• Select the fan speed switch to position I
The unit will now run on low speed.
The element will not activate if the system
water temperature is above 40°C.