background image

M16MI368 - A04 - 12/17 |  9

3. CONNECTION

The electrical installation must comply with local or national regulations. This appliance must be instal-
led by a competent electrician.

•  The technical characteristics of your appliance are shown on the data plate located on the side of the 
  appliance.  Please take note of these before any request for After sales service.
•  Any interventions on electrical parts must be done by a qualified professional.
•  The factory fitted power cable must be connected to the mains by a junction box which will have to  
  be placed behind the appliance, without putting in a power socket and which will be located at least 
  250 mm from the floor. 
•  Supply voltage 230-240V,
•  Connect the 3 core cables as follows: 
  Brown wire = Live  -   Blue wire = Neutral - Black wire = Control Wire (Pilot Wire) 
   This wire must never be connected to the earth and must be isolated,
•  If the supply cable is damaged, it must be replaced by a specific cable.  Replacement of this cable must 
  be done by the manufacturer, their after sales service or people with similar qualifications in order to 
  avoid any danger.
•  RCD of 30mA maximum is compulsary for bathrooms or shower rooms,

4. CONDITIONS OF USE

Refer to the paragraph WARNINGS in point 1. General information

•  The heater can be used continuously without any risk.
•   For operating the electronic regulation refer to the operating instructions.

5. MAINTENANCE TIPS

Maintenance operations must be done with the heater switched off. Therefore take care the appliance is 
off. In order to ensure your heater lasts, we recommend you use the following few tips:
•  Use only mild cleaning agents when cleaning and wiping of the radiator is necessary.
•  Use a dry cloth (without solvent) for the control unit.
•  Use warm soapy water for cleaning the outside walls of the heater (no abrasive or corrosive product).

INSTALLATION AND MAINTENANCE OF YOUR RADIATOR

EN

WASTE DISPOSAL ACCORDING TO THE WEEE DIRECTIVE (2002/96/EC)

The symbol on the product label indicates that the product may not be handled as domestic 
waste,  but  must  be  sorted  separately.  When  it  reaches  the  end  of  its  useful  life,  it  shall 
be  returned  to  a  collection  facility  for  electrical  and  electronic  products.  By  returning  the 

product, you will help to prevent possible negative effects on the environment and health to which the 
product can contribute if it is disposed of as ordinary domestic waste. For information about recycling 
and collection facilities, you should contact your local authority/municipality or refuse collection service 
or the business from which you purchased the product. Applicable to countries where this Directive has 
been adopted.

v2_M16MI368_A04_1217_VN_CHORUS_TEOLYS.indd   9

8/01/18   15:14

Содержание ELECTRIC COLUMN H EXXEC3060 Series

Страница 1: ...MN T OLYS lectrique L HC EH 485 600 180 635 600 330 860 600 555 1010 600 705 1235 600 930 1460 600 1155 L HC EH 450 600 200 550 600 300 650 600 400 750 600 500 900 600 650 1150 600 900 L EH HC EH HC L...

Страница 2: ...55 1830 235 1731 680 1830 460 1731 905 1830 685 1731 605 2030 385 1931 680 2030 460 1931 755 2030 535 1931 L HC EH EV 400 1845 200 1635 600 1845 400 1635 800 1845 600 1635 400 2045 200 1835 450 2045 2...

Страница 3: ...d s Les enfants ne doivent pas jouer avec l appareil Le nettoyage et l entretien par l usager ne doivent pas tre effectu s par des enfants sans surveillance Si le c ble d alimentation est endommag il...

Страница 4: ...s consoles murales fournies dans l emballage Pour une installation correcte du radiateur lorsque l appareil est situ pr s d un mur il est imp ratif de laisser une distance de 250 mm au minimum pour ac...

Страница 5: ...t d assurer les fonctions d abaissement de temp rature s il est raccord un programmateur sp cifique Il ne doit jamais tre reli la terre et doit tre isol de tout contact s il n est pas utilis Si le c b...

Страница 6: ...t des d chets lectriques et lectroniques En respectant ces principes et en ne jetant pas le produit dans les ordures m nag res vous contribuerez la pr servation des ressources naturelles et la protect...

Страница 7: ...it Usercleaningandmaintenancemust not bedonebychildrenwithout supervision If the power cable is damaged it must be replaced by the manufacturer their after sales service or people with similar qualifi...

Страница 8: ...on the ground 2 2 Brackets The radiator must be installed on a vertical wall using the wall mounts supplied For correct heater installation when the appliance is located close to a wall it is essenti...

Страница 9: ...er can be used continuously without any risk For operating the electronic regulation refer to the operating instructions 5 MAINTENANCE TIPS Maintenance operations must be done with the heater switched...

Страница 10: ...Symbol Valeur Unit Puissance thermique Puissance thermique nominale maximale continue o xx 6V Pnom Pmax c 0 50 kW Puissance thermique nominale maximale continue o xx 8V Pnom Pmax c 0 75 kW Puissance t...

Страница 11: ...ominal heat output Maximum continous heat output where xx 6V Pnom Pmax c 0 50 kW Nominal heat output Maximum continous heat output where xx 8V Pnom Pmax c 0 75 kW Nominal heat output Maximum continous...

Страница 12: ...A Rettig Product v2_M16MI368_A04_1217_VN_CHORUS_TEOLYS indd 12 8 01 18 15 14...

Отзывы: