06
HI-LINE Super RC
l
This unit is supplied with factory fitted test leads. Remove
these and discard.
l
A fused electrical spur with a maximum 3A fuse and a switch,
having 3mm separation on all poles, must be provided in an
easily accessible position adjacent to the unit.
l
Electrical cable entry to the unit should be made through the
hole provided at the top left hand side of the unit, using the
cable gland provided.
l
Connect live and neutral wires to the power board terminal
connections, and the earth wire to the chassis earth terminal
(see wiring diagram).
8.0 Electrical Connection
WARNING: This appliance must be earthed. The electrical installation must comply with local or national
wiring regulations.
O O
L N
Motor
Power Board
Control Board
Air Sensor
Water Sensor
O O
Brown
Blue
Wiring diagram
23674 HiLine Super RC manual 27/06/2011 09:25 Page 7