Wire the products using the diagrams shown in section 6.
Do not exceed the maximum load and number of dimming connections as detailed in the specification
(section 9).
To control one or more loads from multiple sensors, wire two or more sensors in parallel using the Live,
Neutral and Switched Live (L/Out) connections only, or wire using the slave input terminals. The
dimming connection(s) from the luminaires must however only be wired to one of the MWS7 sensors.
The sensor should be sited so that the occupants of the room fall inside the detection pattern shown in
section 7. It is recommended for a single-sensor scenario that the sensor is sited near to one end of the
corridor or aisle and angled to provide maximum coverage of the desired area. For a multi-sensor
scenario, it is recommended that the sensors be placed near the centre of the corridor or aisle and
angled correctly to provide maximum coverage of the desired area.
Note that the fully adjustable detection range of the MWS7 provides a well-defined detection area that
extends radially from the sensor. It is therefore advantageous for the sensor to be mounted as low as
possible to provide the minimum range variation for objects of different heights (illustrated in section 7).
Note that the higher the sensor is installed, the effective detection range will become shorter.
Note also that the spread angle of the detection beam shown in section 7 is defined as the area of
maximum sensitivity. Detection is still possible outside these angles, but with a significantly reduced
sensitivity.
Installation Recommendations
Do not site so that the sensor is pointing at any fluorescent lighting
Site the sensor as far away as possible from the surface of metal objects
Site so that the sensor has an un-obstructed view of the desired coverage area
3. Wiring & Fixing