hyp

erion X5 2D / 3D

 - t

echnical manual

EN

Содержание Hyperion X5 2D

Страница 1: ...www my ray com Cod 97071218 Rev 01 01 2017 hyperion X5 2D 3D technical manual EN ...

Страница 2: ......

Страница 3: ... SERVER SOFTWARE INSTALLATION 19 3 9 INTEL PRO 1000 DRIVER UPDATE 21 3 10 ACQUISITION SERVER CONFIGURATION 23 3 11 iRYS SOFTWARE INSTALLATION AND CONFIGURATION 27 4 CALIBRATION See corresponding 3D CALIBRATION MANUAL OPT entry level code 97071221 32 5 CONTROL BOARDS DESCRIPTION 33 5 1 UNIT BLOCK DIAGRAM 33 5 2 POWER BOARD 97661407 34 5 2 1 CONNECTORS LIST 36 5 2 2 FUSES AND DIP SWITCHES LIST 36 5 ...

Страница 4: ...2 EN hyperion X5 2D 3D TECHNICAL MANUAL CONTENTS ...

Страница 5: ...e following 1 If the device is in AIR version check that the screws fastening the column to the wall are not too tightened and the feet are adjusted so that the column is levelled and is not affected by torsion If required loosen 2 of the 4 fixing screws in a cross pattern from top right to bottom left or vice versa so that the column has a little clearance Adjust the feet to make the column rest ...

Страница 6: ...y LED only if using button 96609090 white wire 4 Emission LED only if using button 96609090 blue wire K14 External warning lights clean contacts no voltage provided Optional Use lamps up to 240 VAC max 2 A Use a service relay for higher loads CONNECTOR FUNCTION 1 Ready light 2 3 X ray emission light 4 WARNING Comply with the main supply polarity indicated on connector K17 WARNING The area of input...

Страница 7: ...EMOVAL 2 COVER HANDLES MIRROR REMOVAL 2 1 MONOBLOC COVER Remove the highlighted screws and pull the interlo cking cover 2 2 PANEL COVER Remove the highlighted screws and pull the interlo cking rear cover Loosen the four highlighted screws to remove the front cover ...

Страница 8: ... COVER HANDLES MIRROR REMOVAL 2 3 MIRROR Slightly press the mirror against the column move the mirror upwards and turn it outwards to remove it 2 4 HANDLES Remove the accessory drawer and loosen the hi ghlighted screws to remove the handles ...

Страница 9: ... highlighted screws and remove the cover 2 6 SIDE COVERS Loosen the highlighted screws and remove the interlo cking side covers 2 7 ARCH COVER NOTE Before removing the arch cover it is necessary to remove the sensor cover Loosen the highlighted screws and remove the interlo cking side covers of the arch ...

Страница 10: ...s with the specifications and install the entire software autonomously The 2 PC network cards will be needed for the communication between device and PC and for the connection between Sensor and PC The latter connection is carried out by means of a dedicated network card INTEL PRO 1000 that must be compulsorily used and needs a free PCI E slot on the PC motherboard The operating system of the acqu...

Страница 11: ...D TECHNICAL MANUAL EN PC CONFIGURATION 3 3 OPERATING SYSTEM SETTINGS Open the Control Panel select User Account and then Change User Account Control Settings Select the lowest notification level Never Notify RESTART THE PC ...

Страница 12: ...CONFIGURATION From the Control Panel select Power Options On the Balanced profile select Change plan settings Set Turn OFF display and Put the computer to sleep to Never Select Change advanced power settings Set Hard disk Turn off hard disk after 0 ...

Страница 13: ...ith the mouse on any free area of the desktop with no icons or windows and select Personalize from the context menu Press on the Screen Saver icon in the bottom right corner and select None in the next dialog box 3 4 DISABLING WINDOWS FIREWALL From the Control Panel select Administrative Tools and double click on Services ...

Страница 14: ...local area network or directly to the Acquisition Server PC In both cases the 3D panel Ethernet connection must absolutely be point to point and is always managed autonomously by the software and the machine Therefore it is not necessary to set any IP address on the INTEL PRO 1000 board as it will be set autonomously during the software installation procedure described in the following chapters On...

Страница 15: ...eld and press enter The connection management window will open If a fixed IP address must be set for the network card dedicated to communication right click on the corresponding connection not the INTEL pro 1000 connection but the one supplied by the other network card and select properties Then select Internet Protocol Version 4 TCP IPv4 and click on properties ...

Страница 16: ...er between 1 and 254 except for the device ip address 160 in case of default address The Subnet mask is already filled out properly Click OK to confirm On the other hand in case of connection to a local area network see the following figure the network card for the connection with the device too must have the option Obtain an IP address automatically The DHCP will assign the right IP addresses bot...

Страница 17: ... each panel is equipped with a specific installation CD containing data that are not interchangeable with other units Carefully keep the CD and make sure that at least one backup copy is available Insert the driver CD of the supplied 3D panel and click as displayed in the figure Confirm by Finish ...

Страница 18: ...leora Driver are already present and will uninstall them if necessary WARNING this procedure may take a long time do not interrupt the process At the end the PC will restart and resume installation If this does not occur automatically manually relaunch install exe The screen on the side will be displayed tick off Update Imager Files for L09 and select the HcpConfig ini file Click on INSTALL WARNIN...

Страница 19: ... exe file the screen with the list of network cards available in the PC will appear Only near Intel Pro 1000 board connected to the 3D panel it is necessary that in Current Driver column the eBUS Universal Pro Driver are present In Action column of the other boards select Use manufacturer menu and click Install At the end of installation click Close Restart the PC After PC restart make sure that t...

Страница 20: ...ick on Computer select Properties and select Device Manager in the left column Expand the Network adapters branch and right click on Intel PRO 1000 GT Desktop Adapters select Properties Select Advanced and choose the Jumbo Packet property setting the value to 9014 Bytes ...

Страница 21: ...not displayed directly in this window If it is not displayed search for the Performance Options item and click on Properties The Receive Buffers value is displayed there 3 8 ACQUISITION SERVER SOFTWARE INSTALLATION This software can only be installed on 64 bit Operating Systems Launch the software installer from the setup menu on the usb dongle or from Extranet download and select the language Cli...

Страница 22: ...20 EN hyperion X5 2D 3D TECHNICAL MANUAL EN PC CONFIGURATION Select I accept the agreement then click Next Select the installation for 2D and 3D devices and click on Next Click on Install ...

Страница 23: ...O 1000 DRIVER UPDATE The Intel PRO 1000 ethernet card is automatically recognized from the Operating System However the default system driver should be updated to a specific version in order to ensure the best functionality The updated driver is found in C Program files Common files MyRay Tools double click on the Intel_network_drivers exe file to start the installation Click on Next ...

Страница 24: ...22 EN hyperion X5 2D 3D TECHNICAL MANUAL EN PC CONFIGURATION Choose I accept and click Next Press Next and proceed with the default options Click on Install ...

Страница 25: ...ait Click on Finish Reboot the PC 3 10 ACQUISITION SERVER CONFIGURATION Once the PC IP addresses have been properly set the Acquisition Server can be configured Clicking on the Acquisition Server icon its main window will be displayed in full screen and User mode ...

Страница 26: ...s concerning machine errors the second one bigger Clicking on the Settings icon at top right the connection and software option panel will open Select Change Mode and confirm the application restart message When the programme is restarted the execution mode has to be selected Select Service mode and insert the password cefla Restart the Acquisition Server software which will start in service mode ...

Страница 27: ...IGURATION Go back to Settings select Find Device The device will be searched automatically select it and confirm Select Connect Device and tick off the Auto Connect Device option Click on Close After a few seconds the software will connect to the device ...

Страница 28: ... PC CONFIGURATION Now set the connection with the 3D panel Click again on Settings and on Find Sensor The device 3D panel will be searched automatically Select it and confirm Confirm by Close The acquisition server status is now completely green ...

Страница 29: ...to receive images from the 3D device is iRYS version 6 5 or higher installed in its MAIN WORKSTATION version iRYS must be installed on the Acquisition Server PC Start iRYS installation select 3D device installation and click on Next Select the Stand alone option and click on Next Confirm the installation process and click on Next ...

Страница 30: ... X5 2D 3D TECHNICAL MANUAL EN PC CONFIGURATION Wait and click on Install At the end restart the computer Upon first iRYS launch the display mode has to be selected Oral and Maxillofacial Surgery is the standard mode ...

Страница 31: ...e mode by pressing CTRL ALT SHIFT END simultaneously the Service Level message under iRYS in the main screen confirms proper execution Press ALT F10 and enter the 336699 password Click on Browse in the window that will open and select the C IMAGERs xxxxx folder where xxxx serial number of the installed panel Click on OK ...

Страница 32: ...vice Mode press ALT F10 and enter the 12345 password The window displayed in the figure will open Click on Find Select the device and click on Add selected Make sure that the settings are correct as displayed in the figure tick MainWS and click on Save and then on Exit ...

Страница 33: ...PC CONFIGURATION After saving the settings the following iRYS display will appear Click on the button in the top right corner and select the virtual keyboard from the menu Upon first launch the virtual keyboard will display the following message ...

Страница 34: ... Server software and select Clients Allowed The list of all the clients that have attempted to connect to the virtual keyboard will be displayed Tick off the necessary one s and close Now restarting the virtual keyboard it can connect to the device regularly 4 CALIBRATION See corresponding 3D CALIBRATION MANUAL OPT entry level code 97071221 ...

Страница 35: ...33 EN hyperion X5 2D 3D TECHNICAL MANUAL EN CONTROL BOARDS DESCRIPTION 5 CONTROL BOARDS DESCRIPTION 5 1 UNIT BLOCK DIAGRAM ...

Страница 36: ...NING The K17 input terminal board is always powered live as marked on the info plate below Before handling always cut the power via the external circuit breaker Once the power to the device has been cut wait at least 60 seconds before handling the boards so that the condensers have time to discharge ...

Страница 37: ...35 EN hyperion X5 2D 3D TECHNICAL MANUAL EN CONTROL BOARDS DESCRIPTION ...

Страница 38: ...50v 6 3x32 230V F2 Standby power fuse FUSE 2AT 230V F1 48V output fuse FUSE 2 5AF 450V DC DIP Switches SW1 Always off reserved use 5 2 3 LEDS LIST LED ID COLOR NAME ON BOARD DESCRIPTION DL1 YELLOW ACT CAN communication activity normally flashing Problems on CAN bus If off or on steady DL2 RED ERR Error status normally off Flashing upon startup the number of flashes represents the FW version When E...

Страница 39: ...EN RDYL External ready lamp relay status Normally off on when unit is ready DL24 YELLOW XRYL External x ray on lamp relay status Normally off on during x ray emission DL25 GREEN BUT Xray button pressed On when x ray button is pressed DL26 YELLOW ILK Interlock status Normally off On if door is open or interlock is not connected DL27 RED EMG External emergency button status Normally off On if Extern...

Страница 40: ...38 EN hyperion X5 2D 3D TECHNICAL MANUAL EN CONTROL BOARDS DESCRIPTION PIN 4 signal X ray ON ...

Страница 41: ...39 EN hyperion X5 2D 3D TECHNICAL MANUAL EN CONTROL BOARDS DESCRIPTION ...

Страница 42: ... Switches DESCRIPTION SW4 Not used all OFF SW2 Reboot button SW3 Factory reset switch 5 3 3 LEDS LIST LED ID COLOR NAME ON BOARD DESCRIPTION DL1 YELLOW CAN ACT CAN activity Normally on flashing On steady or off in case of CAN error condition DL2 RED ERR Error status normally off Flashing upon startup the number of flashes represents the FW version When ERR is on the number of flashes from CPU LED ...

Страница 43: ...L23 GREEN 24V 24V tension present normally on DL24 GREEN 5 0V 5V CPU tension present normally on DL25 GREEN 1 2V 1 2V CPU tension present normally on DL32 GREEN 48V R axis Motor tension present normally on DL33 GREEN FCR R axis photocell On if photocell is obscured or disconnected broken DL35 GREEN Not used DL36 GREEN FCX Not used DL38 GREEN 48V Y axis Motor tension present normally on DL39 GREEN ...

Страница 44: ...42 EN hyperion X5 2D 3D TECHNICAL MANUAL EN CONTROL BOARDS DESCRIPTION 5 4 SENSOR INTERFACE BOARD 97661485 ...

Страница 45: ...43 EN hyperion X5 2D 3D TECHNICAL MANUAL EN CONTROL BOARDS DESCRIPTION ...

Страница 46: ...ON 5 4 1 CONNECTORS LIST CONNECTOR DESCRIPTION K1 Sensor synchronisation supply from LOGIC K2 24V DC Panel supply K3 Sensor synchronisation 5 4 2 LEDS LIST LED ID DESCRIPTION DL1 VIN 48V from LOGIC board DL2 VCC Analog 5V towards sensor DL3 VDD Digital 5V towards sensor ...

Страница 47: ...45 EN hyperion X5 2D 3D TECHNICAL MANUAL EN CONTROL BOARDS DESCRIPTION 5 5 MONOBLOC AREA ...

Страница 48: ...AL EN CONTROL BOARDS DESCRIPTION 5 6 KEYBOARD BOARD 97661484 5 6 1 CONNECTORS LIST CONNECTOR DESCRIPTION K1 Keyboard signals from LOGIC 5 7 LOGO BOARD 97661539 5 7 1 CONNECTORS LIST CONNECTOR DESCRIPTION K1 24V power supply fron Logic board ...

Страница 49: ... be centred with respect to the sagittal laser perform a mechanical adjustment Proceed as follows 1 Check that craniostat is centred 2 Close the 2 side tabs 3 Remove lower cover There are no screws just pull the cover downwards 4 Loosen the 2 screws shown in the figure and move the craniostat to align it to the sagittal laser ...

Страница 50: ...ill out and distribute the Report of assembly using the Form FDA 2579 upon completion of an installation and within 15 days of the date of installation For more guidance please refer to FDA document number 1751 Guidance for Industry and Food and Drug Administration Staff Assembler s Guide to Diagnostic X Ray Equipment Please send a photocopy of the Form FDA 2579 to the manufacturer along with the ...

Страница 51: ......

Страница 52: ......