5
5. MECHANICAL INSTALLATION
5.2 Post Bracket Position and A&B Dimensions
Determine the A and B dimension based on the opening angle provided in Table 1 to confirm the position where the post bracket will be mounted.
1.
To ensure that the motor does not touch the pillar, please define your C dimension using B-60 mm formula.
2.
For optimal mechanical advantage A and B dimension shall be equal or not differ by more than 40 mm.
NOTE:
Smaller A and B dimensions determine higher peripheral speed of the leaf. Higher differences between A and B dimensions cause greater speed and force variati-
ons during the gate opening and closing movement. It is always good practice to use all available travel of the operator.
All crushing points must be secured by an entrapment protection according to EU: EN 12453, EN 60335-2-103; GB (UK, NI): BS EN 12453, BS EN 60335-2-103.
5.1 Dimensions of Gate and Operator
LA250EVK with external hardstop,
using max 300 mm travel
LA300EVK with internal hardstop,
using max travel 300 mm
LA300EVK without internal hardstop,
using max travel 350 mm
830 (max.1150)
LA250EVK
Example installation
Herewith you start mechanical installation of the gate operator.
LA300EVK
LA250EVK
1.5 m
250 kg
2.0 m
200 kg
2.5 m
150 kg
LA300EVK
2.0 m
300 kg
2.5 m
250 kg
3.0 m
200 kg
mm
A
100
120
140
160
180
B
100
n.a.
110°
105°
105°
100°
120
110°
110°
100°
95°
95°
140
100°
100°
100°
90°
80°
160
95°
95°
90°
85°
75°
180
90°
90°
80°
75°
70°
mm
A
100
120
140
160
180
B
100
n.a.
110°
105°
105°
100°
120
110°
110°
100°
95°
95°
140
100°
100°
100°
90°
80°
160
95°
95°
90°
85°
75°
180
90°
90°
80°
75°
70°
mm
A
100
120
140
160
180
B
100
n.a.
120°
120°
120°
120°
120
115°
115°
115°
110°
100°
140
105°
110°
110°
105°
100°
160
100°
100°
100°
95°
90°
180
95°
95°
95°
90°
85°
60
80
22
Ø 8.5
100
60
20
7
125
92
133
835
350
55
Max. 350 mm (w/o hardstops)
Max. 300 mm with hardstops
110
92
40
7
Ø8.5
60
85
95
137
Ø10
100
20
Ø10
Ø10
66
30
20
22
15
85
85
52
Extension bracket (not included)
B
A
Gate
Gate Bracket
Gate Operator
Post Bracket
C
B
A
Gate
Gate Bracket
Gate Operator
Post Bracket
Gate Post
Gate Post
Example installation
C
Extension bracket (not included)
Gate
B
B
A
A
Gate Bracket
Gate Bracket
Gate Operator
Gate Operator
Post Bracket
Post Bracket
Gate Post
Gate Post
Gate
Table 1:
Table 1:
Gate leaf bracket extension shall be coside-
red in case the pivoting point of the gate is not
centered with the gate leaf.
Gate leaf bracket extension shall be coside-
red in case the pivoting point of the gate is not
centered with the gate leaf.
85
33
24
70
50
90
11
0
Ø10