Preparation and Filling
Fill the spa to its correct operating level. Be sure to open all valves and jets in the plumbing system before filling to allow
as much air as possible to escape from the plumbing and the control system during the filling process.
After turning the power on at the main power panel, the top-side panel display will go through specific sequences. These
sequences are normal and display a variety of information regarding the configuration of the hot tub control.
Priming Mode – M019*
This mode will last for 4-5 minutes or you can manually exit the priming mode after the pump(s) have primed.
Regardless of whether the priming mode ends automatically or you manually exit the priming mode, the system will auto-
matically return to normal heating and filtering at the end of the priming mode. During the priming mode, the heater is
disabled to allow the priming process to be completed without the possibility of energizing the heater under low-flow or
no-flow conditions. Nothing comes on automatically, but the pump(s) can be energized by pushing the “Jet” buttons.
If the spa has a Circ Pump, it can be activated by pressing the “Light” button during Priming Mode.
Priming the Pumps
As soon as the above display appears on the panel, push the “Jet” button once to start Pump 1 in low-speed and then
again to switch to high-speed. Also, push the Pump 2 or “Aux” button, if you have a 2nd pump, to turn it on. The pumps
will now be running in high-speed to facilitate priming. If the pumps have not primed after 2 minutes, and water is not
flowing from the jets in the spa, do not allow the pumps to continue to run. Turn o he pumps and repeat the process.
Note: Turning the power o
nd back on again will initiate a new pump priming session. Sometimes momentarily turning
the pump o
nd on will help it to prime. Do not do this more than 5 times. If the pump(s) will not prime, shut o he
power to the spa and call for service.
Important: A pump should not be allowed to run without priming for more than 2 minutes. Under NO circumstances should
a pump be allowed to run without priming beyond the end of the 4-5 minute priming mode. Doing so may cause damage to
the pump and cause the system to energize the heater and go into an overheat condition.
Exiting Priming Mode
You can manually exit Priming Mode by pressing a “Temp” button (Up or Down). Note that if you do not manually exit the
priming mode as described above, the priming mode will be automatically terminated after 4-5 minutes. Be sure that the
pump(s) have been primed by this time.
Once the system has exited Priming Mode, the top-side panel will momentarily display the set temperature but the display
will not show the temperature yet, as shown below. This is because the system requires approximately 1 minute of water
flowing through the heater to determine the water temperature and display it.
Fill it up!
READY
RANGE
READY
RANGE
or
*M019 is a Message Code. See “General Messages” Pages.