Configuration
Manual No. SA67-0049-01
4-3
Figure 4-2. Controller Options Dialog Box for new PCI DAC
2. Enable or disable (by checking or unchecking) any of the following
global parameters:
•
Automatic Rebuild Management
. Works in conjunction with
SAF-TE disk array enclosures to detect removal of a failed drive and
perform an automatic rebuild after installation of a replacement
drive. Change the default Rate Controls to less than or equal to 50.
Do this by using the slide bar or typing the rate in the edit box. A
rate of 50 dedicates the maximum allowable resources to a rebuild
allowing it to proceed at its fastest.
•
Background Initialization
. Allows logical drive initialization to
take place “behind the scenes” so that the logical drive is
immediately available for use. If you disable this option, logical
drives will need to complete their initialization process before they
can be used. Change the default Rate Controls to less than or equal
to 50. Do this by using the slide bar or typing the rate in the edit box.
A rate of 50 dedicates the maximum allowable resources to an
initialization allowing it to proceed at its fastest.