Information requirement for the electric local space heaters 

Model identifier(s): MYBWF05ET 

Item   

Symbol  Value 

Unit  Item   

Unit 

Heat output 

Type of heat input, for electric storage local space 
heaters only (select one) 

Nominal heat output 

Pnom 

0.5 

kW  manual heat charge control, with integrated 

thermostat 

No 

Minimum heat output 
(indicative) 

Pmin 

0.5 

kW  Manual heat charge control with room and/or   

outdoor temperature feedback 

No 

Maximum continuous 
heat output 

Pmax,c 

0.5 

kW  electronic heat charge control with room and/or 

outdoor temperature feedback 

No 

Auxiliary electricity consumption 

fan assisted heat output 

No 

At nominal heat 
output 

elmax 

NA 

kW  Type of heat output/room temperature control (select 

one) 

At minimum heat 
output 

elmin 

NA 

kW  single stage heat output and no room 

temperature control 

No 

In standby mode 

elSB 

0.00025  kW  Two or more manual stages, no room 

temperature control 

No 

 

with mechanic thermostat room temperature 
control 

No 

Model identifier(s): MYBWF08ET

 

with electronic room temperature control 

No 

Item   

Symbol  Value 

Unit  electronic room temperature control plus day 

timer 

No 

Heat output 

electronic room temperature control plus week 
timer 

Yes 

Nominal heat output 

Pnom 

0.8 

kW  Other control options (multiple selections possible) 

Minimum heat output 
(indicative) 

Pmin 

0.8 

kW  room temperature control, with presence 

detection 

No 

Maximum continuous 
heat output 

Pmax,c 

0.8 

kW  room temperature control, with open window 

detection 

Yes 

Auxiliary electricity consumption 

with distance control option 

No 

At nominal heat 
output 

elmax 

NA 

kW  with adaptive start control 

No 

At minimum heat 
output 

elmin 

NA 

kW  with working time limitation 

Yes 

In standby mode 

elSB 

0.00025  kW  with black bulb sensor 

No 

Contact details 

Hygiene Supplies Direct Limited, Ground floor, Tayson House, 
Methley Road, Castleford WF10 1PA 

 
 

Содержание MYBWF05ET

Страница 1: ...ructions carefully You must inspect the appliance including its cable and plug for any signs of damage If the product is damaged DO NOT USE and contact your supplier immediately for refund replacement...

Страница 2: ...not operate the unit or carry out maintenance and or clean the unit Any infirmed persons in the vicinity of the unit should be accompanied by a responsible and competent able bodied adult Remove the...

Страница 3: ...manufacturer for replacement Do not connect the appliance to extension cables or multiple outlets Do not damage or knot the power cable Before cleaning the appliance or carrying out any maintenance sw...

Страница 4: ...children and vulnerable people are present This appliance is not intended for use by persons including children with reduced physical sensory or mental capabilities or lack of experience and knowledge...

Страница 5: ...dren this appliance should be installed so that the lowest part of the heater rail is at least 600 mm above the floor The heater is to be installed so that switches and other controls cannot be touche...

Страница 6: ...ecial requirements are needed in this area Our product attains IPX4 so it can be installed in Zone 2 or Zone 3 Make sure that the distance from walls and objects is respected INSTALLATION OF TOWEL RAI...

Страница 7: ...INSTALLATION B C x2 M4 x 6mm D 800mm SOL 600mm 150mm 150mm 150mm D 10mm...

Страница 8: ...wall plugs C Fasten the hanging rack on the wall with the screws making sure the hanging rack is in correct direction D Gently insert the bottom of the heater first to the bottom of the hanging rack a...

Страница 9: ...ttom corner you will hear a sound which indicates the unit is in standby the standby indicator is illuminated 3 Press standby button to start the heater For the first use the heater is in default sett...

Страница 10: ...inute setting the screen displays Press and to set the current minute Press to confirm all settings Note The clock and calendar will reset to factory default settings if unit is completely powered dow...

Страница 11: ...de for garages caravans etc Using the Preset programs 1 and 2 Note Clock and day setting must be set for correct usage of P1 P2 programs It is advised to set day and clock in advance for the program t...

Страница 12: ...fort mode 01 00am 05 00am ECO mode 05 00am 09 00am comfort mode 09 00am 19 00pm ECO mode 19 00pm 00 00am Figure 2 P2 Saturday Sunday preset program 00 00am 01 00am comfort mode 01 00am 08 00am ECO mod...

Страница 13: ...ure 4 P3 Saturday Sunday Adjustable program 01 00am 05 00am ECO mode 05 00am 01 00am Comfort mode Figure 5 How to adjust P3 program setting It is good practice to spend time carefully studying and pra...

Страница 14: ...erature can be set to your needs by simply pressing the or button at any time whilst the unit is in operation Open window function Press and button together the screen displays then it comes back to d...

Страница 15: ...r advice MAINTENANCE 1 The appliance needs regular external cleaning only 2 After use and before cleaning always unplug or switch the unit off at the power socket and wait until the item is cool 3 Whe...

Страница 16: ...ndby mode elSB 0 00025 kW Two or more manual stages no room temperature control No with mechanic thermostat room temperature control No Model identifier s MYBWF08ET with electronic room temperature co...

Страница 17: ...old wastes throughout the EU To prevent possible harm to the environment or human health from uncontrolled waste disposal recycle it responsibly to promote the sustainable reuse of material resources...

Отзывы: