Mylek MHPH05-10E Скачать руководство пользователя страница 4

6  |

|  7

INSTRUCTION

MANUAL FOR MODELS

| SPECIFICATIONS

Model No.

RATED VOLTAGE

RATED POWER

MHPH05-10E

AC230-240V, 50-60Hz

1000W

MHPH05-15E

AC230-240V, 50-60Hz

1500W

MHPH05-20E

AC230-240V, 50-60Hz

2000W

| STRUCTURE AND PARTS

1

2

3

1 - Out-let

2 - Body

3 - Control panel

| INSTALLATION ON THE WALL

≥300mm

ø 8mm

Image 3

Image 4

Image 5

Image 6

Image 1

Image 2

300mm

300mm

300mm

300mm

MHPH05-E

Figure 1

•  For wall mounting, carefully remove the already constructed hanging bracket from 

the rear of the heater by turning the two plastic securing grips located at the top of 

the bracket. It is good practice to remove the bracket and replace a few times so you 

are familiar on how it attaches before securing to the wall.

•  Using the hanging bracket as a template, place the hanging bracket level against the 

wall as a guide ruler (please make sure the holes are parallel level), use a marker 

pen to mark the hole position. Image 2 on Figure 1 above.

•  Drill holes on the wall with Ø8mm drill bit. Image 3 on Figure 1 above.

Содержание MHPH05-10E

Страница 1: ...or any signs of damage If the product is damaged DO NOT USE and contact your supplier immediately for refund or replacement This product is only suitable for well insulated spaces or occasional use BE...

Страница 2: ...competent able bodied adult Remove the packing and make sure that the appliance is intact If there is any doubt concerning the integrity of the unit do not use the appliance and contact our recommende...

Страница 3: ...t be incorporated in the fixed wiring in accordance with the wiring rules For correct installation on the wall thanks to refer to Installation on wall part Fixed heaters are to be installed so that sw...

Страница 4: ...ting carefully remove the already constructed hanging bracket from the rear of the heater by turning the two plastic securing grips located at the top of the bracket It is good practice to remove the...

Страница 5: ...o electrical wiring gas pipes water pipes etc in the area to be drilled To fix the feet pls see the picture as below If not use for wall mounted pls assembly the feet as above picture CONTROL PANEL AN...

Страница 6: ...y simply pressing the once and once again to revert back to set temperature Anti frost mode Press the button until the screen displays In this mode you cannot set the countdown timer or adjust the tem...

Страница 7: ...r will stop working The screen will display Press to set the unit back to normal operation Figure 2 P2 Saturday Sunday preset program 00 00am 01 00am comfort mode 01 00am 08 00am ECO mode 08 00am 11 0...

Страница 8: ...ing label Select your country code enter your mobile number and select Get to receive a message containing your verification code Enter your verification code and select Login When the first using to...

Страница 9: ...u set P3 manually on the unit and you choose P3 in the APP the unit will operate to the settings you have set You can also choose to set to your own requirements by selecting the Smart Timer within th...

Страница 10: ...on off background color changing If on the background color will change according to the temperature Room temperature calibration Use this function to set the Room Temperature Calibration to the corre...

Страница 11: ...Pmax c elmax elmin elsb 1 0 1 0 No No 0 00061 no no no no Unit Nominal heat output kW kW kW kW kW With black bulb sensor no no no no no no yes yes yes no no no Contact details Hygiene Supplies Direct...

Страница 12: ...u have any problems with this product please call our Help Desk on 0800 091 3171 or email sales hygienesuppliesdirect com Model identifier s MHPH05 20E P Manual heat charge control with integrated the...

Страница 13: ...YESSS Electrical YESSS House Normanton WF6 1TN declares that the Mylek Heaters are exclusively manufactured and imported for Hygiene Supplies Direct Ltd...

Отзывы: