3.   INSTALLATION

 3.1  PRELIMINARY CHECKS

Before the installation, to ensure correct working of the automation, please check the followings:

• Make sure the gate’s structure is suitable to be automated

• Check the weight, dimensions and type of the gate is appropriate to this type of automation

• Ensure the  gate is able to open and close smoothly and is free of obstacles that may cause the gate to potentially   

   derail

• Check the ground and all surfaces for the installation are suitable for stable and safe fixing of the gate automation.

• Make sure the installation area for the automation is wide enough to accommodate the anchor plate and the motor  

   can be accessed easily in the event of power cuts. 

• Ensure the location where the automation is installed is not exposed to flood hazards; if in doubt raise the automation   

   from above ground level.

• In cases where the automation has to be installed in a vehicles path or manoeuvre area, it is recommended to protect 

   it against accidental damage. 

• Ensure an efficient earth connection system is in place.

• Make sure the surfaces for photocells fixing areas are flat and smooth enough to allow a perfect alignment between 

   transmitting and receiving units. They must both directly see each other as they are not reflective.

   

3.2    ELECTRICAL SET-UP

3.2.1   STANDARD INSTALLATION

3.2.2 ELECTRICAL CABLES SPECIFICATIONS

The cables required the electrical set-up (not included in the pack) may vary according to quantity and type of 

devices installed. 

Fig. 1

A

  Security cost 

2x0,75

B

   Power Supply 

2x1,50 + terra

C

  Photocells 

rx 4x0,75

  Photocells 

tx 2x0,75

D

  Key switch 

2x0,75

E

  Warning light 

2x0,75

230V

2x0,75

2x1,50+T

rx 4x0,75

tx 2x0,75

2x0,75

2x0,75

24V

ENGLISH

ENGLISH

Содержание strike

Страница 1: ...OPENER FOR RACK DRIVEN SLIDING MOTOR STRIKE English Installation manual...

Страница 2: ...CE COMPLIANCE DECLARATION MYGATE is a trademark by PROTECO S r l Manufacturer PROTECO S r l Address Via Neive 77 12050 Castagnito CN ITALIA declares that The product type STRIKE Electromechanical gear...

Страница 3: ...6 MDAM10Z Nut 10 for motor anchor plate fixing 7 MPC06 Cable grommet SH70 8 MTP22 Slot cover 9 MGR0610Z Limit bracket fixing screw 6x10 for universal steel brackets only 10 MVI3595D Screw TC 3 5x9 5...

Страница 4: ...installed is not exposed to flood hazards if in doubt raise the automation from above ground level In cases where the automation has to be installed in a vehicles path or manoeuvre area it is recomme...

Страница 5: ...abricated hole in the gear motors anchor plate Pay attention to the plate s orientation hole for cables routing on the side opposite the gate see Fig 2 c Set concrete into the pit Ensure this is level...

Страница 6: ...just the four screws accordingly Then tighten all nuts f Release the gear motor for manual operation as illustrated in section 6 of this manual 3 6 ASSEMBLY THE RACK 3 6 1 INSTALLING THE TOOTHED RACK...

Страница 7: ...e rack is perfectly straight and level d Weld the threaded stand off to the gate Fig 10 e Move the gate manually checking that the rack is always resting on the motors drive pinion cog and weld second...

Страница 8: ...sing and opening bracket according to the motor position against the gate fig 15 b Manually close the gate up to 3cm before the closing mechanical stop c Put the two fixing screws on the closing limit...

Страница 9: ...re that the electric limit switch is always activated in opening and closing before the gate reaches its mechanical stops Place the two slot covers on the M10 screws Lift the motor cover down and clos...

Страница 10: ...g the release and re locking procedure to avoid any accidental activa tion of the gate 6 1 How to unlock the motor for manual opera ting a Insert the key into the lock and turn it anti clockwise Fig 1...

Отзывы: