I .Working Condition 

Using at normal temperatures and pressure. Please do not stay in too cold, too hot, 
too dry and too wet. 
 
 
 
 
 

II

Technical Specification 

Rated input voltage:AC220V-240V 50HZ /AC110V-120V 60Hz 
Rated input power:350VA 
 
Cool cold slimming Vacuum 
Power: Up to 200W 
Cooling device output temperature: 5~ -10

 

Cooling device output :0-5Kpa 
Cooling liquid: pure water 

Vacuum: 650mmHg 

Pump flow rate: 60L/min 

Vacuum pressure: 0-100Kpa 

Cavitation frequency : 40KHz 

7.

 

Fat exploding frequency: 35-40K 

Cavitation Power: up to 60W 
Cavitation tip: 60mm diameter 
 
RF for BODY 

Содержание WL-7202C

Страница 1: ......

Страница 2: ... reading and consulting Please follow the instruction to fit and operate the machine correctly Please do not remove and change any accessories of the machine It forbids others others to open and remove the mainframe except the authorized people in the company It forbids others to change and maintain the machine except the professional people Please contact us if there is any trouble during operati...

Страница 3: ...ents using the following medical electrical equipment can not use the equipment Implanted cardiac pacemakers or other implanted electronic devices Life sustaining artificial heart lung machines and other equipment Portable ECG measurement equipment The following patients should be agreed by the professional doctors before using the equipment Patients with acute Malignancy Patients with Infectious ...

Страница 4: ...g available please contact your local representative 1 2 Conventions Note Notes designate information of special interest Caution Cautions alert the user to precautionary steps necessary to properly operate the system Failure to observe these cautions may void the warranty Warning Warnings alert the user to information that is of the highest importance and vital to the safety of the patient and us...

Страница 5: ...e the body such as metal teeth or silicone breast implants 6 People with abnormal immune system 7 People with numb or insensitive to heat 8 If you are feeling unwell Prohibited in the ears nose eye throat and do not use this device in advance and tell your doctor 9 Children under 12 years old are not allowed III Treatment Safety 1 Treatment Time is less than 30mins Body Part Each Treatment 2 The e...

Страница 6: ... input voltage AC220V 240V 50HZ AC110V 120V 60Hz Rated input power 350VA Cool cold slimming Vacuum Power Up to 200W Cooling device output temperature 5 10 Cooling device output 0 5Kpa Cooling liquid pure water Vacuum 650mmHg Pump flow rate 60L min Vacuum pressure 0 100Kpa Cavitation frequency 40KHz 7 Fat exploding frequency 35 40K Cavitation Power up to 60W Cavitation tip 60mm diameter RF for BODY...

Страница 7: ... 7 RF frequency 3MHz RF power up to 150W RF for FACE RF frequency 3MHz RF power up to 30W Chapter 2 Installation How to input water A Connect the funnel to the input water hole ...

Страница 8: ...ter with pipe D The water is full after the water overflows from the overflow hole Then put on the blue rubber to the overflow hole E The drainage hole is to make out the water Chapter 4 Operation I 1 User interface 1 Press welcome to enter the main menu in Page1 ...

Страница 9: ...r the 2 Cryo handles B Work time refers to the time of operation which can be set as needed C Temperature refers to freezing temperature e g 0 5 3 D Pressure refers to suction intensity which can be set as needed In page3 E Cryo handle 1 and Cryo handle 2 can works at the same time also can work alone ...

Страница 10: ...the water circulation the machine will stop itself in 5 seconds to protect the mac hine 5 Operations Steps 1 Clean the skin first then smear the products onto the treated skin please use anti freeze when work with cryolipolysis handle 2 According the client s fat part status adjust the Intensity and the Vacuum mode and Working time 3 Turn on the Cryolipolysis system Working on the body ...

Страница 11: ...riginal 40K head 4 Single function interface in Page 4 1 refers to the time of operation which can be set as needed 2 refers to fat exploding Energy which can be set as needed 3 refers to fat exploding mode selection Only difference is the interval working time of exploding 4 Please click to start or pause function ...

Страница 12: ...1 refers to the time of operation which can be set as needed 2 refers to RF heat Energy which can be set as needed 3 Pro means normal mode for this RF working model when choose this mode energy will reach the user setted slowly Nor professional mode temperature will reach to the one u setted at once 4 Please click ...

Страница 13: ...k to the main function interface Eye RF 6 Single function interface in Page 6 1 refers to the time of operation which can be set as needed 2 refers to RF heat Energy which can be set as needed 3 Pro means normal mode for this RF working model when choose this ...

Страница 14: ...e take another freezing process to treat the same location for 2 3 months which can reduce the excess fat thickness Such a secondary treatment can consolidate the fat dissolving effect but multiple treatments are not recommended 4 Cryolipolysis cool sculpturing treatment is designed for those physically healthy people who have local fat deposits but not suitable for the one with overall obesity It...

Страница 15: ...ceiving treatment the patient should be sitting making a 90 angle between his her upper part of the body and thigh 8 Use the freezing device to suck the skin of treatment area gently and then set the intensity of the vacuum suction 9 Use appropriate and constant suction intensity the suction intensity is adjustable according to the patient s individual vulnerability At the same time the mode of su...

Страница 16: ... The following patients shall have the professional physician s consent before using the machine Acute disease patient Cancer patient Infectious disease patient Pregnant women Heart disease patient Fever patients Patients receiving another treatment or those with physical anomalies 5 Careful attention should be paid to following patients when using this machine Infants and young children People wi...

Страница 17: ... 17 Product name Purchase date deadline Seller Add Tel 18948755929 Customer Add Tel Repair date Reason of the f ault Repair content Maintain list ...

Страница 18: ... 18 ...