MX-300, 120, 300, 500, 500H Manuals & Troubleshooting

Low Batteries & bad battery connections are the #1 cause of scale malfunction and inaccuracy! We test all of our 
scale returns from consumers. Fully 60% of consumer returns are battery related problems. This sounds silly but 
it's true! A scale will perform slowly, or read inaccurately when it has low batteries.Please replace the batteries often 
(and only use good qualitybatteries). We include good quality batteries with all of our scalesbut batteries can run 
low in storage. If your scale simply won't turn on while on Battery power, this is often caused by loose battery 
connections. Battery prongs (terminals) are made of metal. They must be making good contact with your batteries 
in order for the scale to power on. You can use a paperclip to slightly bend the battery prongs to make them have a 
better connection. Also some poorly designed batteries have recessed or partially obstructed battery terminals. 
This may cause your prongs to be touching the plastic housing of the battery instead of the metal battery terminal.

Thank you for purchasing the MX. With normal care and proper treatment it will provide years of reliable service. 
Please read all operating instructions carefully before use.

TROUBLESHOOTING & OPERATION NOTES:

1) If the Display ever becomes locked showing "Out2", please recalibrate the scale as outlined in the manual

2) If the Display ever becomes locked on 1HHHH, LLLL or EEEE, this indicates that the scale was shocked, 
dropped or otherwise damaged and the delicate weighing sensors have been damaged. You can try recalibrating 
the scale (If the sensor has not been hurt too badly it will work again after recalibration). Otherwise you will have to 
follow the warranty instructions that came with your scale.

3) If the display becomes locked on 8888, this often indicates low batteries. However sometimes it also may 
indicate a serious zero mark error. This means when you turn the scale on, it can't determine what zero is (a slight 
zero mark error will cause situation #1 above) Thus, if new batteries do not fix this error the scale will have to be 
sent to us for replacement under our Lifetime/30 year warranty program.

4) If the display shows UNST, this means the scale is not stable. Please try operating the scale on a more stable 
surface and be sure nothing is on the tray or stuck under the tray when you turn it on. If this situation persists, it 
may be an indication of fatal load cell damage. Try calibrating the scale - if this does not work please follow the 
warranty instructions.

Although the MX-300 is designed to be extremely durable, It

ʼ

s important that you never overload or drop/shock the 

scale. Scales are delicate instruments and unlike Cellular phones, scales have delicate sensors that determine how 
much an item weighs. If you drop or shock your scale, these sensors "feel" the shock and are sometimes 
destroyed. This happens with all digital scales. We design our scales to be as resistant to shock or drops as 
possible, however there is no way for us to protect 100% against load cell or sensor damage. A well-treated scale 
will provide years of reliable and accurate weighing. However an abused scale will only work until it

ʼ

s sensors are 

damaged.

MX-300 & MX-300 Special Edition

MANUAL & OPERATION GUIDE
PLEASE READ COMPLETE INSTRUCTIONS BEFORE USE
Thank you for purchasing the MX With normal care and proper treatment it will provide years of reliable service. 
Please read all operating instructions carefully.

.KEEP THE FOLLOWING POINTS IN MIND:
* If the display becomes locked on Out2 please recalibrate the scale.

* Do not Overload (exceed the capacity) of the scale including the weight of any trays or bowls combined with 

Содержание MX-300 Special Edition

Страница 1: ...My Weigh MX Series Models User Manual ...

Страница 2: ... that came with your scale 3 If the display becomes locked on 8888 this often indicates low batteries However sometimes it also may indicate a serious zero mark error This means when you turn the scale on it can t determine what zero is a slight zero mark error will cause situation 1 above Thus if new batteries do not fix this error the scale will have to be sent to us for replacement under our Li...

Страница 3: ...________________________ If your scale ever performs slowly inaccurately or shows the battery icon please replace the batteries Battery Operation 1 Three AAA size Heavy Duty or Alkaline batteries are required 2 To install batteries a Release the battery cover by sliding the locks in wards b Place batteries into battery compartment aligned correctly c Replace battery cover and lock it DO NOT USE EX...

Страница 4: ...is not in use it will help protect the scale from possible damage MX TROUBLESHOOTING OPERATION NOTES 1 If the Display ever becomes locked showing Out2 please recalibrate the scale as outlined in the manual 2 If the Display ever becomes locked on LLLLL or EEEEE this indicates that the scale was shocked dropped or otherwise damaged and the delicate weighing sensors have been damaged You can try reca...

Страница 5: ...od care of your MX 300 MX 300 My Weigh is the Best Weigh MX 120 MX 300 Original Series Manual PROPER OPERATION AND ENVIRONMENT If the display ever becomes locked on Out2 please recalibrate the scale as outlined below Always use a gentle touch on the buttons don t press hard Avoid lengthy exposure to extreme heat or cold your scaleworks best when operated at normal room temperature Always allow the...

Страница 6: ...ey Calibration Procedure for MX120 MX200 Version 2 0 2002 Models 1 Turn the scale OFF and Place the it on a Flat very stable surface Be certain the scale is OFF 2 Press and hold the TARE key for 5 seconds until a random large number appears on the display Then release the key 3 Press and release the TARE key again the display will show 2Ero and then 100 0 4 Gently place a 100 gram weight on the sc...

Страница 7: ... again to return thedisplay to 0 0 OFF Press and release to turn off the scale Auto Off An auto shut off feature is provided to conservebattery power The unit will automatically turn off after approximately2 minutes of inactivity BATTERY OPERATION If your scale ever reads LO performs slowly or inaccurately pleasereplace the batteries Be sure the batteries are tightly in theircompartment and are ma...

Отзывы: