background image

Illustration 3: 

UV Light System in Horizontal Position with Whole House 

Water Filtration with dual bypass

 

 
 
 
 

 

Содержание TWIN BIG BLUE WHOLEHOUSE WITH UV GUARD

Страница 1: ...UV GUARD ULTRAVIOLET LIGHT Thank You for trusting us with your Water Filtration needs Please read and follow the steps below on setting up your Product If you need any help please call us at 1800 769 300 or contact us through our website at www mywaterfilter com au contacts or email us at customerservice mywaterfilter com au ...

Страница 2: ...PARTS ...

Страница 3: ...DIMENSIONS ...

Страница 4: ... can create harm in the work area Unpack and check that you have received your product in good condition If it has been damaged in transit please do not attempt to install or assemble the unit Alert us immediately orassoonaspossible so wecan provide the necessary assistance Please inspect the glass parts of the UV system in your box then plug in the Controller and UV Lamp Turn it on to ensure it w...

Страница 5: ...tration unit This will ensure that the ultravioletlight systemwillperform optimallyand the shadowing effect will be prevented A pre filtration of at least 5 micron is required before the ultraviolet light system The Shadowing Effect occurs when dirt or debris passes through the unit Bugs and bacteria hide inside this debris if not pre filtered and pass through the light without being killed Treat ...

Страница 6: ...EASY INSTALLATIONGUIDE CLICK HERE TO WATCH THE VIDEO ...

Страница 7: ... System Complete with Ultraviolet Light will be installed Look for a desirable position where the system can be fixed securely 2 The whole house big blue filter system bracket has 2 x holes to attach it onto the wall Fix the water filter onto the wall or frame with strong screws or bolt ...

Страница 8: ...ed In and Out on the top of the housing or from left to right These systems come pre assembled However if your flow direction is right to left the bracket must be removed from the system and needs to be turned around 180 degrees then reconnected 5 The inlet plumbing will be attached to the In port on the filter system The outlet plumbing from the whole house big blue filter system will be attached...

Страница 9: ...ou should install a pressure limiting valve before the water filter to ensure no excess pressure is exerted into the system Installing Gauges Please take care when installing the gauges please apply plumbers thread tapeonlytothe gauge thread Ifrubber o rings aresupplied with your system that is all you will require to seal the gauges no thread tape will be needed Tighten taking extra care the thre...

Страница 10: ...ame 8 Make sure that there is enough free space to service the replacement of either the glass quartz thimble sleeve or the UV lamp Otherwise it will not be possible to maintain the UV system Allow at least 1 metre to pull out the UV lamp when required 9 When mounting the chamber consideration must be made for the weight of the system including the stresses associated with pipework etc Ensure pipe...

Страница 11: ...open the valve on the mainline and let the whole house big blue filter system fill with water Once full water will flow out of the opened tap nearest the water filter Allow the water to flow for a few minutes before use Initially black carbon water will flow out from the tap so you might want to collect the first black water flowing from the filter into a bucket as it will be very black carbon wat...

Страница 12: ...SAMPLE INSTALLATION SETUP DIAGRAM Illustration 1 UV Light System in Vertical Position with Whole House Water Filtration ...

Страница 13: ...Illustration 2 UV Light System in Horizontal Position with Whole House Water Filtration ...

Страница 14: ...Illustration 3 UV Light System in Horizontal Position with Whole House Water Filtration with dual bypass ...

Страница 15: ...Illustration 4 UV Light System in Horizontal Position above Whole House Water Filtration ideal for locations with lessspace ...

Страница 16: ... UV lamp into the quartz thimble sleeve via the hole through the centre of the sealing nut If the stainless steel chamber is installed vertically NEVER DROP the UV lamp into the quartz thimble sleeve as this may break the quartz thimble sleeve In this case for vertical installation you MUST connect the Lamp onto the electrical lead and lower the lamp into the chamber 3 Hold the UV lamp firmly by t...

Страница 17: ...ndicated in the Installation Diagrams above so any condensation or water is able to drip off the power lead and not flow into the electrical components NOTE It will take around 30 seconds cycling time for the lamp to reach full output when first turned on Whenever the UV light is turned on you must allow 30 seconds of time minimum for the UV lamp to build up to full operating capacity before you t...

Страница 18: ...imble sleeve as it may come out of the chamber at the same time Remove the sealing nut from the quartz thimble sleeve and store it in a safe place You can then remove the quartz thimble sleeve from the chamber NOTE Take care with single ended chambers with spring thimble support as the spring will suddenly push the thimble out of the chamber when the sealing nut becomes disengaged from the thread ...

Страница 19: ...ng tool to remove the housing by turning it anticlockwise 4 Once loosened with the tool the housing can be removed by hand Spin the housing counterclockwise Spin until the housing is completely removed NOTE If the pressure is not released the filter housing will be very difficult to loosen It is imperative that the water pressure is released prior toattempting to remove the filter housing ...

Страница 20: ... ring and housing threads with food grade silicone grease 7 Ensure the cartridges centre hole is seated in the stump in the base of each housing Ensure the cartridge is centred vertical as you lift the housing up into the head cap thread to replace Hold 1hand under the housing asyou screw back on the whole house big blue filter housing by turning it clockwise Do this until it is hand tight If lubr...

Страница 21: ...g to release the air inside the whole house big blue filter system This will ensure that no air pockets are trapped inside 11 Let the water flow out of the opened tap nearest to the water filter for a few minutes until the BLACK Carbon water has been flushed out and the water is clear again You might want to collect the first flow of water into a bucket as it may be very black water from the carbo...

Страница 22: ...Having Troubles withyoursystem Call us at 1800 769 300 My Water Filter Pty Ltd ...