1
、
Insert the wheel shaft J to the corresponding hole of feet pipe E
,
insert the cotter K to the
corresponding holes; slide the plain washer I over the wheel shaft J put the wheel H to the two sides
of shaft,
,
screw the nut G to fix the wheel on the shaft.
2
、
Put the heater body on the feet pipe assembly, make sure the 4 holes of handle A point towards the
corresponding 4 holes on the feet pipe respectively.
3
、
Using the screw B ,spring washer C, plain washer D and nut F to fix the feet pipe assembly and
handle to the tank.
5. Installation Instructions
Position the heater on a flat, level, non-flammable, solid surface.
The exhaust gases are very harmful for people and animals when released in a closed
space without ventilation.
Indirect-fired heaters while used in indoor installation, must be connected to an exhaust
pipe to vent the products of combustion outside. To maintain an adequate Oxygen rate, a
minimum of 80 m
3
/h airflow from outside must be ensured.
Direct-fired heaters are intended for use in outdoor open areas or in indoor well
ventilated areas. For indoor use, provide permanent ventilation openings of at least 25
cm²/kW, equally distributed between floor and high level, with a minimum of 250 cm².
BGO-100A-16-F
Minimum Opening Size
2500
cm²
•
Only install the heater in normal upright position.
•
Do not place the heater near walls, corners or low ceilings.
•
Do not place the heater below a socket outlet.
•
Do not place the heater on moving vehicles or where it can tip over.
•
Keep the heater away from flammable, combustible, explosive or corrosive materials.
•
Keep the heater away from curtains or similar materials that could block the air inlet and
outlet.
•
Never block or restrict the air inlet and outlet for any reason.
•
Keep the power cable away from heat sources, sharp edges, cutting and moving parts.
•
Do not expose directly to the weather or to excessive humidity.
•
Do not place the heater in the immediate surroundings of a bath, shower or swimming
pool.
•
Follow general and special fire safety regulations in force in all fields of applications. In
any case ensure the following minimum safety clearances from materials or objects in
the surroundings of the heater:
•
Side:
1 m
•
Air inlet side:
1 m
•
Top:
1.5 m
•
Hot air outlet side:
3 m
•
Floor:
0 m
•
Floors and ceilings must be made of fireproof materials in the place where the heater is
operated.
•
Do not connect direct-fired heaters to air ducts.
6. Instructions for Use