background image

E1 displayed on 

the screen   

Faulty or damaged power cord 

Check and replace if needed 

Faulty motor/capacitor 

Check and if necessary replace 

Lock-out of appliance due to previous 

overheating 

Detect the cause of overheating 

Shut the appliance down 

Check air inlet and outlet 

Wait some minutes and restart the 

appliance 

E2 displayed on 

the screen 

The temperature probe is faulted or the 

connector for temperature probe is 

loosen 

Check and replace if the temperature 

probe if needed 

Check and replace the PCB if needed 

Motor runs, but the 

heater does not 

ignite and locks 

out after a short 

time 

E1 displayed on 

the screen   

Empty fuel tank, dirty or wrong fuel 

Remove wrong or dirty fuel 

Fill the tank with clean Diesel or kerosene 

Ignition fault, dirty or incorrect 

electrods position 

Check and clean electrods 

Fuel filter clogged 

Clean or replace fuel filter 

Burner nozzle clogged 

Clean nozzle blowing compressed air, 

replace if necessary 

Fuel viscosity increased at low 

temperature 

Mix Diesel with 10-20% kerosene 

Heater starts but 

combustion is not 

good 

Insufficient airflow into combustion 

chamber 

Check air inlet, fan, motor and air collar 

position, adjust it if necessary. 

Wrong fuel pressure 

Check fuel pressure, adjust it if needed 

Leaks in fuel line 

Check and fix fuel leaks 

Heater stops 

during operation 

Ambient 

temperature 

displayed on the 

screen   

The room temperature set on room 

thermostat has been reached 

Normal operation 

To start turn the temperature control knob 

clockwise on a higher setting   

Heater stops 

during operation 

E1 displayed on 

the screen 

Flame failure 

Check and remove the cause(s) of 

malfunction 

To reset, turn On/Off switch to 0 and then 

to I   

Call technical service if the problem 

persists 

Bad combustion 
Reduced airflow 

Overheating 

LC displayed on 

the screen 

Failed 3 times for igniting will lock the 

PCB and stop working 

With electricity on,  it will be unlocked afte

r 3 times power switch to ON in 10 secon

ds;  

M1.0.WD340.EN

Содержание BGO-100A-16-F

Страница 1: ...Instruction Manual Diesel Kerosene Heater WD340 M1 0 WD340 EN Please read and keep for future reference...

Страница 2: ...ranty or representation for any particular purposes The information is offered in good faith and with the understanding that any use of the units or accessories in breach of the directions and warning...

Страница 3: ...EN INCORRECTLY USED E G INDOORS WITHOUT ADEQUATE AIR CIRCULATION OR IF NOT PROPERLY WORKING CO POISONING MAY LEAD TO DEATH GENERAL HAZARD WARNING FAILURE TO COMPLY WITH THE PRECAUTIONS AND INSTRUCTION...

Страница 4: ...et Weight kg 40 8 Length mm 1215 Width mm 580 Height mm 705 Tank Capacity l 69 Operating range h 7 Standard Accessories Fuel gauge yes Handle 1 Ambient thermostat built in Malfunction detection signal...

Страница 5: ...of at least 25 cm kW equally distributed between floor and high level with a minimum of 250 cm BGO 100A 16 F Minimum Opening Size 2500 cm Only install the heater in normal upright position Do not pla...

Страница 6: ...FF O position The post ventilation phase will cool down the combustion chamber for 90 seconds Unplug the unit when not used for a long time Never disconnect the heater from mains to stop it while in o...

Страница 7: ...er into the heater Never use solvents gasoline toluene and similar aggressive chemicals to clean the heater The following checks BY QUALIFIED PERSONNEL ONLY are recommended before every seasonal use F...

Страница 8: ...usted by qualified technicians only Tampering with the unit may be dangerous Remove pressure gauge cap P Connect a pressure gauge on the pressure measuring port on pump Start heater and read fuel pres...

Страница 9: ...e setting pressure on fuel pump Fig 6 This setting adjustment can be necessary to prevent excessive smoke emission due to lack of Oxygen Fig 7 Electrical Inspect cables electrical parts and connection...

Страница 10: ...ged Clean nozzle blowing compressed air replace if necessary Fuel viscosity increased at low temperature Mix Diesel with 10 20 kerosene Heater starts but combustion is not good Insufficient airflow in...