11

TDD10 - NLFREN - v1.0 - 11042017

EN

TOOLS

2.2  Work and dormancy status

• 

When the panel works normally, if the liquid flows through or you operate the buttons, the control panel LCD shows work 

status.

• 

If no liquid flows through or you do not operate the buttons, one minute later the control panel will be in dormancy status, 

LCD does not display.

• 

If the liquid flows through or you operate the buttons again, the control panel LCD will display, the control panel will be 

waken up and normal working status restored.

2.3  Calibration work status

Note: Only in the unit LTR for calibration

For automatic factory calibration, please follow these steps:

•  Batteries are not installed on the body, then a short circuit board jumpers J2. After the installation of batteries, it will display 

00000, which means it has been entered into the calibration status. Install the control panel to the shell.

• 

When 100 liters of calibration liquid flows at the control pipeline, the flow value of the flowed liquid will be displayed on 

LCD screen. The liquid flows out, about 30 seconds, control panel will record the flow value, calculate the flow coefficient 

(k) values and deposited CPU of the permanent preservation of nonvolatile memory, even removed the battery discharge 

coefficient (k) will not lose value. If the flow of calibration error is over more than the limited 10%, the panel will consider 

the current calibration value is invalid, and will not record the current calibration value, the screen will show the letters Err, 

and then show the figure 00000, re-entry into the auto-calibration status.

•  If the calibration IS successful, still want to re-calibration, please remove the batteries and repeat the above steps.

•  Automatic calibration is completed, please remove the battery, then disconnect the circuit board jumper J2, then the battery 

can be fitted into the normal working status.

                 

c46.33

Fig. 2

User manual calibration by following these steps:

•  To press DISPLAY and CALIBRATE about 2 seconds at the same time will enter the 

user manual flow coefficient (k) calibration status, such as: k = 46.33, at this time 

LCD displays information in figure 2.

• 

Numerical after “c” (such as 46.33) is the modified flow coefficient (k) value, the number of flashes that can be modified, 

and modify the scope: 0 to 9, the position can be shifted by press the CALIBRATE button shortly.

•  To press DISPLAY shortly can increase the numerical from 0 to 9, increase only, can not reduce.

• 

After modification, press DISPLAY and CALIBRATE simultaneously, it can return to normal working status.

• 

User manual flow coefficient (k) calibration correction formula:

 

When the user found that the actual traffic flowed liquid flow has a larger error with displayed flow, using the following 

formula to re-calculated k value: 

l x k

0

L

0

Note:

I

 = flow rate of flow meter

k

0

 = current flow (not to amend before) k value

L

0

 = user graduated cylinder measures the value

Users to manually modify the k value, for example:

Clear “0” TTL1 value or remove the batteries, to clear TTL1, TTL2 “0”, fitted with batteries, button is shifted to TTL1 status. 

Start the measurement of liquid flow, the flowed liquid enters into the standard cylinder. Record the displayed flow value and 

graduated cylinder flow value after the liquid flows out, such as displayed flow 

l

 = 95.56 LTR, graduated cylinder measures the 

value 

L

0

 = 100 LTR, current k value ( not to amend before ) 

k

0

 

= 40, calculated as follows: 

95.56 x 40

100

= 38.224

As it only keeps the 2 numerical after two decimal, k

 

=38.22.

copyrighted 

document 

- all 

rights 

reserved 

by 

FBC

Содержание 724574199

Страница 1: ...eller Compteur diesel Diesel flow meter P 02 Gelieve te lezen en voor later gebruik bewaren P 06 Veuillez lire et conserver pour consultation ult rieure P 10 Please read and keep for future reference...

Страница 2: ...or de gebruiker 1 3 Prestaties en technische parameters Stroomvoeding twee R03 UM 4 1 5 V batterijen Meetnauwkeurigheid 1 LCD scherm toont het huidige debiet de debietco ffici nt en fautcode Werktempe...

Страница 3: ...n de batterijen opnieuw ingezet worden en het toestel treedt in de normale werkmodus c46 33 Fig 2 Ga als volgt te werk voor de manuele kalibratie door de gebruiker Druk gelijktijdig op DISPLAY en CALI...

Страница 4: ...atterijen is het niet noodzakelijk het toestel van het verdeelsysteem los te koppelen 4 De batterijen vervangen Verwijder de 4 schroeven in de hoeken van het bedieningspaneel en neem de elektronica LC...

Страница 5: ...ervang deze indien nodig Computer defect Contacteer de technische dienst van uw verdeler Normaal debiet maar de teller telt niet en het toestel herstart als u op DISPLAY drukt Kalibratie methode niet...

Страница 6: ...Performances param tres techniques Alimentation deux piles R03 UM 4 1 5 V Pr cision de mesure 1 cran LCD affiche la valeur du d bit actuel le coefficient de d bit et le code d erreur Temp rature de s...

Страница 7: ...s piles peuvent tre r install es pour entrer en mode de fonctionnement normal c46 33 Fig 2 Pour la calibration manuelle de l utilisateur suivez les tapes suivantes Appuyez en m me temps sur DISPLAY et...

Страница 8: ...placer les piles il n est pas n cessaire d enlever l appareil du syst me de distribution 4 Remplacer les piles Enlevez les 4 vis dans les coins du panneau de commande et sortez la partie lectronique c...

Страница 9: ...s piles et remplacez les si n cessaire Panne d ordinateur Contactez le service technique de votre revendeur D bit normal mais le compteur ne compte pas et l appareil red marre quand vous appuyez sur D...

Страница 10: ...UM 4 1 5 V common batteries Measurement accuracy 1 LCD display shows the current flow value calibration and fault code Operating temperature range 10 60 C Flow rate 150 l min 1 4 Jumper definition an...

Страница 11: ...the above steps Automatic calibration is completed please remove the battery then disconnect the circuit board jumper J2 then the battery can be fitted into the normal working status c46 33 Fig 2 Use...

Страница 12: ...remove the instrument from the pipeline system the batteries can be replaced 4 Batteries replacement Remove the four angle screws from the instrument s control panel take the computerized electronic i...

Страница 13: ...ted Remove the computer and if necessary check and reinstall or replace the batteries Computer failure Contact your dealer Normal flow rate but the instrument does not count and when pressing DISPLAY...

Страница 14: ...angeduide richtlijnen met inbegrip van deze betreffende het tijdstip van de verklaring der geldende veranderingen R pond aux normes g n rales caract ris es plus haut y compris celles dont la date corr...

Отзывы: