5.2 Emergency
stop
The Unifixer 65 has 2 emergency stops that immediately stop the rotation of the heating
drum. They are easily reachable, one on the front right hand side and one on the rear right
hand side.
A third emergency break is the front cover. In case of opening the cover, all mechanical
processes will stop immediately.
Be aware that opening the front cover will not stop the heaters.
5.2.1 Emergency
reset
To run the machine, the emergency stop must be released and the user protection cover
must be in working position. Once done, press on the reset button to reset the safety
mechanisms.
Refer to
Operation panel on page 34
When switching the machine on with the main switch, press the safety reset button to activate
the machine.
Important
If a situation requires an immediate shutdown of all activities push the
emergency without hesitation.
If using the emergency break, make sure to remove all materials such as
protection paper, transfer paper and fabric as soon as possible.
Important
Before resetting the emergency brake, make sure solve the situation that
caused the emergency shutdown.