User’s Guide Spitfire 65/90 Extreme
CHAPTER 2: Product overview
22
AP-75197– Rev. 1.2
2.2 HEATER SYSTEM
Under the print platforms, heater strips are attached. Each heater can be set separately. Please refer to the
table below to know the function of each heater.
Heater element
Function
Pre-heater (Heater A)
Open the pores to make the media more receptive for Mild Solvent Plus Series Ink
Fixer (Heater B)
To establish optimum fixation onto the media (coated and uncoated).
Optimizes the dot gain control.
Post-Fixer (Heater C)
The post-fixer finalizes the fixation process and helps to make the prints touch-dry.
Dryer (Heater D)
The dryer completes the drying for compatibility with the take-up in combination
with higher output speeds.
Stickiness of printed banner materials is improved.
There have been a number of requests from the field, asking the heaters to be on by default for a few user
settings. This has now been implemented as follows:
For user 1 and user 8 default settings are as follows:
Pre heater A:
50°C
Fixer B:
40°C
Post Fixer C:
50°C
Dryer D:
50°C
For users 2
7, by default the heaters are still OFF.
Notes
Please note some RIP software do not allow selection of the user from software side. In some
cases, however, they do automatically activate user 8.
Содержание Spitfire 65 Extreme
Страница 2: ...User s Guide Spitfire 65 90 Extreme 2 AP 75197 Rev 1 2 ...
Страница 4: ...User s Guide Spitfire 65 90 Extreme 4 AP 75197 Rev 1 2 ...
Страница 13: ...User s Guide Spitfire 65 90 Extreme CHAPTER 1 Safety instructions 13 AP 75197 Rev 1 2 N Type 1 2 4 5 ...
Страница 14: ...User s Guide Spitfire 65 90 Extreme CHAPTER 1 Safety instructions 14 AP 75197 Rev 1 2 6 7 8 9 10 ...
Страница 16: ...User s Guide Spitfire 65 90 Extreme CHAPTER 2 Product overview 16 AP 75197 Rev 1 2 ...
Страница 42: ...User s Guide Spitfire 65 90 Extreme CHAPTER 4 Periodical maintenance 42 AP 75197 Rev 1 2 ...
Страница 128: ...User s Guide Spitfire 65 90 Extreme 128 AP 75197 Rev 1 2 ...