Installation Guide Blizzard
9
AP-75261 – Rev. 2.0 – 19/12/07
1 INSTALLATION ENVIRONMENT
It is very important that the installation environment fulfils following conditions to obtain stable print quality.
1.1 INSTALLATION ENVIRONMENT REQUIREMENTS
Choose a place for printer installation following the requirements in the table below.
65” model
23,5 m² or larger (please refer to chapter “Required Space”)
Area
90” model
25,7 m² or larger (please refer to chapter “Required Space”)
Floor loading capability
2940Pa (300kg/m²) or more
65”
90”
Voltage AC
100-120V
AC 220-240V
AC 100-120V
AC 220-240V
Frequency 60/50Hz
60/50Hz
Electrical
Capacity
AC100V-120V : 11 A
AC220V-240V : 5.5 A
AC100V-120V : 12 A
AC220V-240V : 6 A
In order to protect the printer for over currents, short circuits and earth faults, the building
installation should be equipped with an automatic breaker double pole of 20 A and an earth
leakage switch of 300 mA.
Recommended
working
environment
Temperature: 23°C
Humidity: 55%, without condensation
Operational
conditions for mild/
eco- solvent ink.
Temperature: 20°C - 30°C
Humidity: 40% to 65%, without condensation
Rate of change
Temperature: No more than 2°C per hour
Humidity: No more than 5% per hour
Ambient
conditions
Storage and
transport conditions
Temperature: 4°C to 50°C
Humidity: 40 to 80%, without condensation (When ink has been
discharged.)
N
OTES
•
A
VOID THE FOLLOWING TEMPERATURE AND HUMIDITY CONDITIONS
.
O
THERWISE
,
PRINTED IMAGES MAY
APPEAR DIFFERENTLY FROM WHAT YOU EXPECT
:
ο
P
LACES WHERE SUDDEN CHANGES IN TEMPERATURE AND HUMIDITY ARE EXPECTED
,
EVEN THOUGH
THE CONDITION IS WITHIN THE RANGE WRITTEN ABOVE
.
ο
P
LACES WHERE DIRECT SUNLIGHT OR EXCESSIVE LIGHTING ARE EXPERIENCED
.
ο
P
LACES WHERE AIR CONDITIONERS BLOW DIRECTLY
.
•
MUTOH
RECOMMENDS THAT THE PRINTER IS INSTALLED IN A PLACE WHERE AIR CONDITIONING CAN BE
ADJUSTED EASILY
.
•
I
F THE RECOMMENDED WORKING ENVIRONMENT CANNOT BE MET AND OUTPUT QUALITY ISSUES ARISE
,
THE
BEST APPROACH TO MINIMISE THE EFFECTS IN THIS CASE IS TO REDUCE THE OUTPUT SPEED
.
I
N SUCH A CASE
,
WE RECOMMEND SWITCHING FROM
360
X
360
DPI TO
540
X
720
DPI OR TO
720
X
720
DPI
.
Содержание Blizzard
Страница 1: ...Installation Guide Blizzard For Authorized Mutoh Technicians and installation purposes only ...
Страница 2: ...Installation Guide Blizzard 2 AP 75261 Rev 2 0 19 12 07 ...
Страница 4: ...Installation Guide Blizzard 4 AP 75261 Rev 2 0 19 12 07 ...
Страница 12: ...Installation Guide Blizzard 12 AP 75261 Rev 2 0 19 12 07 ...
Страница 42: ...Installation Guide Blizzard 42 AP 75261 Rev 2 0 19 12 07 ...
Страница 68: ......