background image

- 23 -

Содержание 24

Страница 1: ...Swimming Pool Heat Pump User and Service Manual ...

Страница 2: ......

Страница 3: ...lusion of the entire guarantee and warranty The manufacturer declines any responsibility for the damage caused to people objects and errors due to incorrect installation It is the owners responsibility to ensure that the pool or spa water maintains correct water chemistry balance as bad water chemistry can damage the heat pump internal components which will not be covered under this warranty Any u...

Страница 4: ... 380 415V 50Hz 3PH 380 415V 50Hz 3PH Running Current Heating A 6 7 8 Advised pool volume with pool cover m 75 120 90 130 Advised water flux m3 h 6 2 12 7 1 14 Water Pressure Drop KPa 16 18 Heat exchanger Titanium in PVC Water connection mm 50 No of Fan 1 Ventilation type Horizontal Fan Speed RPM 650 Noise level 10m dB A 47 48 Noise level 1m dB A 57 58 Net Weight kg 91 113 Net Dimension WxDxH mm 10...

Страница 5: ... chemicals must take place in the piping located downstream from the heat pump 2 Install a bypass if the water flow from the swimming pool pump is more than 20 greater than the allowable flow through the heat exchanger of the heat pump 3 Install the heat pump above the water level of the swimming pool 4 Always place the heat pump on a solid foundation and use the included rubber mounts to avoid vi...

Страница 6: ...ensions 3 3 Distance from your swimming pool The heat pump is normally installed within a perimeter area extending 7 5 m from the swimming pool The greater the distance from the pool the greater the heat loss in the pipes As the pipes are mostly underground the heat loss is low for distances up to 30 m 15 m from and to the pump 30 m in total unless the ground is wet or the groundwater level is hig...

Страница 7: ... 5 3 5 Typical arrangement Note This arrangement is only an illustrative example ...

Страница 8: ...el Connect the electrical wires to the terminal block marked POWER SUPPLY A second terminal block marked WATER PUMP is located next to the first one If you are using a secondary pump to circulate water from the pool to the heat pump this pump can be connected to the second terminal block here This allows the filter pump operation to be controlled by the heat pump 3 8 Initial operation Note In orde...

Страница 9: ...an dramatically reduce the required length of heating time is highly recommended as standard Water Flow Switch The heat pump is fitted with an automatic flow switch to protect the heat pump from inadequate water flow If the pool water level is higher than 1m above or below the heat pump s automatic adjustment knob your dealer may need to adjust its initial startup Time delay The heat pump has a bu...

Страница 10: ...ssories installation Anti vibration bases 1 Take out 4 Anti vibration bases 2 Put them one by one on the bottom of machine feet like the picture Draining jet 1 Install the draining jet under the bottom panel 2 Connect with a water pipe to drain the water Note Lift the heat pump to install the jet Never overturn the heat pump as it could damage the compressor ...

Страница 11: ...n onto the heat pump 2 Install the two joints like the picture shows 3 Screw them onto the water Inlet outlet junction Mains cable wiring Please refer to the photo Water pump wiring 1 With the connector 1 and 2 you can pilot the water filtration through the timer of the filtration dry contact ...

Страница 12: ...ctrically isolated from the rest of the unit Grounding the unit is still required to protect you against short circuits inside the unit Bonding is also required Disconnect A disconnect means circuit breaker fused or un fused switch should be located within sight of and readily accessible from the unit This is common practice on commercial and residential heat pumps It prevents remotely energizing ...

Страница 13: ...on of the display Photo 1 Photo 2 Photo 3 Disassembling of and degrafage control board of the connector photo1 Installation of the provided cable photo 2 To pass the cable by the press pack photo 3 and to connect the sons directly 5 3 Connection to pilot the water pump Dry contact timer connection Dry contact pump connection ...

Страница 14: ...the inlet water temperature Press to stop the heat pump unit 6 3 Choose heating or cooling mode Press until heat or Cool light is on 6 4 Setting the real time On standby or running mode press then press or to adjust hour minute Then press the again to store the new data When setting the time and cannot work 6 5 Water temperature setting On standby or running mode press or to adjust the desired wat...

Страница 15: ... Press again to store the new data 6 7 Cancel the automatic start stop To cancel the automatic starter Press then press light off and the automatic start is off To cancel the automatic starter Press then press light off and the automatic stop is off Note If the water filtration system is stop before the heat pump the unit will shut down security condition and the code EE3 or ON advertise on the co...

Страница 16: ... operation parameter table 7 2 How to adjust the parameters Can only adjust on standby mode 1 Long press for 10 seconds press again to select the data from 0 to L see operation parameter table you want to adjust 2 Then press or to adjust the parameter press again to store the new data 3 Then press or select the other datas you want to adjust repeat above operation ...

Страница 17: ...5 Please kindly noted A Press MODE to choose mode Mode only be changed for 1 or 2 setting of parameter 6 B Mode can be changed while running C Auxiliary electrical heating is not applicable to these modes ...

Страница 18: ... 16 7 3 How to know the current status ...

Страница 19: ...ent steps of electronic expansion valve 18 94 70 Adjustable B Inlet water temperature 9 99 Exact testing by value C Outlet water temperature 9 99 Exact testing by value D Condenser temperature under heating mode 9 99 Exact testing by value E Gas return temperature 9 99 Exact testing by value F Ambient temperature 9 99 Exact testing by value G Condenser temperature under Cooling mode 9 99 Exact tes...

Страница 20: ...r pump will run automatically for first grade antifreeze Second grade antifreeze protection in Winter PP7 Ambient temperature or water inlet temperature is too low Heat pump will start heating for second grade antifreeze Cooling condenser sensor failure PP8 The sensor in open or short circuit Check or change the sensor High pressure protection EE1 1 Refrigerant is too high 2 Air flow is not enough...

Страница 21: ...ode displays 1 Chosen the wrong mode 2 Figures show defects 3 Controller defect 1 Adjust the mode to proper running mode 2 Replace the defect LED controller and then check the status after changing the running mode verifying the water inlet and outlet temperature 3 Replace or repair the heat pump unit Short running LED displays actual water temperature no error code displays 1 Fan NOT running 2 Ai...

Страница 22: ... 20 9 Exploded Diagram Model MUSTANG 24 ...

Страница 23: ...sor 12 Front panel 42 Seal ring for flow switch 13 Isolation plate 43 Sensor clip 14 Compressor 44 Titanium heat exchanger 15 Separator 45 Red rubber ring 16 Base tray 46 O ring 17 Wire fixing clip 47 Water connection 18 Water pump terminal 48Water in temp sensor 19 Pressure gauge 49 Blue Rubber ring 20 Handle 50 Drainage plug 21 Right panel 51 Electric box cover 22 Power supply terminal 52 PCB 23...

Страница 24: ...witched off you should check the unit is full of water before the unit starts to run again 5 When the unit is running there will always be a little water discharge under the unit this is normal 6 Refrigerant pressure For checking the unit under running model make sure there is refrigerant pressure gauge which shows working condition of unit The following mapping table shows the number of refrigera...

Страница 25: ... 23 ...

Страница 26: ......

Отзывы: