Step 6 - Evacuate any air remaining in cell (Fig. 6).
FIGURE 5
FIGURE 6
Step 7 - Follow the RE-ARMING and REPACKING instructions.
DISASSEMBLY
If your device has been inflated, the inflation cell must be inspected (see INSPECTION, STORAGE
AND MAINTENANCE), completely deflated, clean and COMPLETELY DRY before re-arming and
repacking.
Step 1 - Unpack, or open, the Rescue Stick™ assembly on a clean, flat, and dry surface so that the
inflator is visible (Fig. 7).
FIGURE 7
FIGURE 8
Step 2 - Remove the handle, containing the discharged CO2 cylinder, by firmly rotating counter-
clockwise (Fig. 8). To ensure that you do not re-install a used cylinder, discard immediately. If
cylinder is discharged, replace with new handle. Ensure the cylinder has not been pierced. See
RE-ARMING.
Rescue Stick
™
Owner’s Manual
5