Declaration of Conformity
Special Instructions for Safe Use
1.
The whole wiring harness must be mechanically protected from impact and UV by using suitable environmental
metal guarding.
2.
The unused connector port must be sealed with provided blank plug. (87-04-0013)
3.
The display unit must only be powered by a DC voltage source from 6.5VDC to 32VDC
and protected by a 2A fuse.
4.
The display must only be replaced with Murphy part number 78-70-0248.
5.
The anti-static warning label (78-05-0827) must be fixed near the display or a suitable label with the words
‘
WARNING – POTENTIAL ELECTROSTATIC CHARGING HAZARD – SEE INSTRUCTIONS
’ must be placed in its stead.
6.
All standard practices for working in a hazardous area must be complied with. Only personnel qualified to work in
this hazardous area and on this type of equipment may carry out operational and maintenance work.
7.
The display unit
must
be protected from impact by installation in a panel or by a suitable shield. The shield shall be
all metal or Murphy-approved Alternate (78-70-0428). The shield must be capable of withstanding a 7 joule impact
without damage to the display unit. Site risk assessment / local authority inspection will determine amount of
shielding required.
8.
Along with all instructions in this document the display unit must also be installed following the Murphy installation
instructions and manual.
Содержание PowerView PV101-A-HAZ
Страница 3: ...Mounting Instructions Shield Illustrations...
Страница 4: ...Wiring Instructions...