00-02-0714
2018-06-21
Section 78
PowerView
- Model PV101-A-HAZ
Instructions regarding ATEX Directive 94/9/EC
The Murphy PV101-A-HAZ has been tested in compliance with EN 60079-0:2009 and EN 60079-15:2010.
II 3G Ex nA T3 -
10˚C ≤ T
a
≤ +70˚C
To ensure compliance with this ATEX standard, the following must be adhered to:
The display apparatus and associated harness must only be operated in the ambient temperature range
-
10˚C to +70˚C
No plugs shall be disconnected while the unit is energized. A warning label, of suitable material, stating
‘WARNING – DO NOT SEPARATE WHILE ENERGIZED’ must remain adjacent to all connections throughout the
unit’s service life.
Only Murphy PV101-A-HAZ displays and Murphy-approved for ATEX plugs, sockets and harness connection
points may be used as replacements.
WARNING - SUBSTITUTION OF COMPONENTS MAY CAUSE
IGNITION OF A COMBUSTIBLE OR FLAMMABLE ATMOSPHERE.
Enovation Controls must be consulted before changing any
component.
Any harness replacement wiring must be Murphy (P/N 78000125) or Murphy-approved for ATEX.
All wiring must be routed away from any sources of impact. If this is not possible metal guarding must be
used.
Routinely inspect connections of plugs and sockets also ensuring all connections are secure in their
positions.
WARNING – POTENTIAL ELECTROSTATIC CHARGING HAZARD.
Wipe only with a damp cloth, this includes the display unit and any
of its shielding.
Содержание PowerView PV101-A-HAZ
Страница 3: ...Mounting Instructions Shield Illustrations...
Страница 4: ...Wiring Instructions...