background image

 

Section 78 

 

00-02-0805

 

12-09-11

 - 

24 -

 

 

Return to both engines (port and starboard) on Plug A 

 
 
 
 

Содержание HelmView HV750

Страница 1: ...00 02 0805 12 09 11 Section 78 HelmView ModelHV750 Operations Manual ...

Страница 2: ...ifications and designs at any time The latest version of this manual can be found at www fwmurphy com Please read the following information before installing BEFORE BEGINNING INSTALLATION OF THIS MURPHY PRODUCT Read and follow all installation instructions Please contact FW MURPHY immediately if you have any questions ...

Страница 3: ...the First Time 5 Product Features 7 Power Up 7 Main Menu 7 Gauge Display 8 Engine Diagnostics 10 Fault Code Pop ups 11 User Settings 13 Utilities 19 Data Logger 19 Trip Parameters 20 Accessing the Hidden Screens 21 System Settings screen 22 Service Reminders screen 22 CAN GROUP Settings screen 23 Gauge Screen Addendum 25 ...

Страница 4: ... THIS PAGE INTENTIONALLY LEFT BLANK ...

Страница 5: ...ble for download Many frequently asked questions are stored on the forum along with demo configurations and examples on how to configure products Please use the link below and register for the forum http forum fwmurphy com Once you register you will receive your user name and password confirmation in separate emails Go to the Forum and log in a page displays indicating a successful login Almost im...

Страница 6: ...d or right of the display They change according to the options available for the screen displayed Soft Keys The soft keys correspond to the soft key commands and allow you to make selections accordingly MENU Key Pressing the MENU key at any time displays the list of menu options ENTER Key Pressing the ENTER key selects the option displayed much like the ENTER key on a keyboard The ENTER key also b...

Страница 7: ...me The guidelines below are intended for setting up the HV750 display for the first time If you require assistance during the set up process contact FW Murphy Customer Support at 918 317 4100 1 At the Main menu press the soft key to the left of Utilities 2 The Utilities displays ...

Страница 8: ...ress Press the Save soft key to save changes or the Restore Defaults soft key to return to the default settings Service Reminders Factory defaults for Service Reminders apply automatically on first use of the HV750 Normally you should not need to access the Service Reminders screen FACTORY DEFAULT VALUES Change Engine Oil Default interval 50 0 Hrs Chang Air Filters Default interval 75 0 Hrs Change...

Страница 9: ...any time by pressing the Menu key on the display Access the following features through the Main menu Gauge Display provides a series of screens that display engine transmission and auxiliary information in a variety of formats Engine Diagnostics displays a list of engine fault codes descriptions and messages User Settings allows you to customize the display options for ambient light and brightness...

Страница 10: ...uded in the HV750 A GPS device must be connected to the HV750 to provide time and other readings from which to calculate trip and fuel information To scroll through the various gauge screens press the Previous and Next soft keys Repeat this action until all screens have been viewed The currently displayed screen stays active until another key is pressed To review all screens available without acce...

Страница 11: ...reen Video Day Night The feature allows you to toggle the display screen between Day View and Night View There are two night view options available Red and Blue and a Backlight Toggle that turns OFF the backlight in a blackout Sleep Mode The Backlight Toggle function only turns the backlight off The unit will operate as normal but with no backlight Home When the Home key upper left appears on a sc...

Страница 12: ... Red Night View Blue Backlight Toggle Engine Diagnostics Choose Engine Diagnostics from the Menu for the HV750 to query the Engine Control Unit s and provide feedback on any activated service codes Faults displayed are based on engine or auxiliary sources ...

Страница 13: ...ined by SAE J1939 If not translated into text see the SAE standard or the engine manufacturer s literature Count The number of times the event has been flagged Description The common SPN s and FMI s have a text description stored in the HV750 display If there is no text then define this SPN FMI by referring to the engine manufacturer s literature or the SAE J1939 standard Correction Troubleshootin...

Страница 14: ... it only hides the pop up message When a fault code has been hidden a Recall icon remains on the right side When this soft key is pressed the fault code displays again When a fault message is activated a pop up message is displayed until the alarm is acknowledged by pressing the Hide key Warning showing Warning hidden Recall button showing Scrolling Through Multiple Messages The title bar of the f...

Страница 15: ... page 9 and 10 of this document The Backlight Toggle turns the backlight off to Sleep mode You can reach this from the User Settings screen or from any screen if either of the top two soft keys left and right are unassigned Hold the soft key down for 5 seconds to turn OFF the backlight This function only turns the backlight off The unit continues to operate as normal but with no backlight Press an...

Страница 16: ...s in 1 and 5 increments until the desired brightness is achieved NOTE Brightness levels will change with ambient light setting You can save two brightness levels one for day and one for night Units Select how units display by using the soft keys to select from the following USA Standard Metric kPa Metric Bar British Standard ...

Страница 17: ... will be provided in future software updates or posted on the forum at http forum fwmurphy com Screen Setup Initially Gauge Screens are listed in default order You scroll through them using the Previous and Next soft keys The Screen Setup allows you to turn specific screens ON or OFF depending on what you want to monitor Turn a screen ON by selecting the check box To turn a screen OFF click the ch...

Страница 18: ...ture quality and resolution can occur if the correct Video Mode is not selected NOTE The HV750 reboots when you change the video input mode Time Zone Offset Time is provided via GPS signal through your GPS receiver Most GPS devices convert GPS time to UTC Coordinated Universal Time Time Zones are normally offset from UTC by a whole number of hours UTC 12 to UTC 14 Use the Up and Down Arrows to scr...

Страница 19: ... Once all changes have been made press Save The following confirmation screen is displayed Press the Enter soft key to Save or press the Menu soft key to Cancel Restore Defaults Restore Defaults sets all the features of the display to the original factory settings During troubleshooting you can use this as a last resort to reset the display to a known state ...

Страница 20: ...12 09 11 18 To restore the default user settings press the soft key for Restore Defaults The following confirmation screen displays Press the Enter soft key to Restore Defaults or press the Menu soft key to Cancel the action ...

Страница 21: ...screens see Accessing the Hidden System Settings Screens on page 21 Data Logger Use the Data Logger function to record the J1939 parameters being read by the HV750 The parameters recorded are defaulted to those that display on gauges and screens The recorded information can be downloaded to a USB device Press the Start soft key to begin recording Press the Stop soft key to stop recording To downlo...

Страница 22: ...lay fuel used during all or part of a voyage Press the adjacent soft key to select Calc The HV750 will use all engine trip fuel data to calculate a fuel usage number The Trip Fuel gallons liters display on the GPS gauge screen To clear a trip press the soft key adjacent to the Reset Trip icon The following warning displays Press the Enter key to continue or press the Menu key to Cancel the action ...

Страница 23: ...ngs You reach these screens from the Main Menu Instructions on how to use each of these screens is included in this section To reach the Hidden Menus 1 Press the second Soft Key down on the right side twice 2 Press the third Soft Key down on the right side twice 3 The Utilities displays 4 Use the adjacent soft key to choose from the menu at left ...

Страница 24: ...ilable options Once you have selected all options press Save Service Reminders screen The Service Reminders screen allows you to reset the five built in service reminders Default Intervals Change Engine Oil Default interval 50 0 Hrs Chang Air Filters Default interval 75 0 Hrs Change Hydraulic Oil Default interval 100 0 Hrs Service Engine Default interval 125 0 Hrs Service Machine Default interval ...

Страница 25: ... for Save to save the changes CAN GROUP Settings screen Initially port and starboard engines are on one plug Plug A The CAN GROUP screen allows you to switch the settings so the starboard engine remains on Plug A and the port engine is moved to Plug B Press the soft key adjacent to the Plug A and B button NOTE Making this change causes the HV750 to reboot To return to both port and starboard engin...

Страница 26: ...Section 78 00 02 0805 12 09 11 24 Return to both engines port and starboard on Plug A ...

Страница 27: ...dum This section contains a view of each gauge screen in the Murphy Standard version of the HelmView HV750 Review these to see what options are available before setting your preferences on the User Settings screen Propulsion Engine 1 Propulsion Engine 2 ...

Страница 28: ...Section 78 00 02 0805 12 09 11 26 Dual Engine 1 Dual Engine 2 Auxiliary 1 ...

Страница 29: ...Section 78 00 02 0805 12 09 11 27 Dual Auxiliary Transmission 1 Dual Transmission ...

Страница 30: ...Section 78 00 02 0805 12 09 11 28 Overview Tanks GPS Screen ...

Страница 31: ......

Страница 32: ...MurCal c CALL MURCAL TO PLACE YOUR ORDER P 661 272 4700 F 661 947 7570 www murcal com e mail sales murcal com ...

Отзывы: