background image

Installation 

00-02-0483

page 2 of 4

Basic Operation

As condensate rises in the scrubber, the float
on the L1200NDVOR rises and trips its pneu-
matic valve. The valve opens allowing pres-
sure to enter the dump valve pilot chamber.
Once the pressure enters the pilot chamber it
forces the diaphragm and valve stem forward
thus opening the valve seat (valve open/closed
indicator button pops out) and releasing con-
densate through the valve stem and out the
drain. As the condensate level drops, the
L1200NDVOR pneumatic valve closes to shut
off the pressure to the dump valve causing it to
close.

If for any reason the condensate continues to
rise beyond normal dump levels, model L1200
operates the alarm and/or shuts down the
equipment.

The  L1200NDVOR Filter/Regulator and the
MURPHYGAGE

®

help keep the control pres-

sure clean and dry. They also allow the opera-
tor to adjust pressure to recommended levels.

NOTE: Always use clean, dry, 

instrument quality gas.

TYPICAL INSTALLATION ON GAS COMPRESSORS

DVU Series Installation

The following describes the “Direct Mounting” method to the
tank wall.

1.

Install the valve so the drain connection is on the bottom. Use
pipe thread sealant on all the connections.

2.

Be sure the unit is screwed tight and does not leak.

3.

Install the piping for the pneumatic input signal into the
1/8 NPT threaded connection of the pressure inlet port (on
top of the diaphragm housing of the DVU).

6.

Install a union between the DVU drain connection and the
condensate out line. Use pipe thread sealant on all the con-
nections.

V

e

s

s

e

W

a

ll

Union

Upper Assembly
(removable) 

Valve
Union

Pneumatic
Input Signal

Maintenance
Bolt

Valve Indicator

Drain
Connection

Weep Hole

Condensate Out

2-Way (Manual Drain) 
Shutoff Valve

Fig. 4 

Typical 

Dump Valve 

Installation

CAUTION:

ALWAYS USE “NON-SPARKING TOOLS”

WHEN GAS IS KNOWN TO BE PRESENT.

WARNING

WARNING

Fig. 3

Scrubber/Separators

Filter/Regulator &

MURPHYGAGE

®

“Instrument

Quality Air/Gas

Supply”

Pneumatic Level Control

Float actuated level snap-acting switch

controls pneumatic pressure to open

and close dump valve.  

L1200NDVOR: 

Dump Valve Operator,

pressure regulator, and pressure indi-

cating MURPHYGAGE

.

®

Two piece union design with manual valve operator

allows soft plug and hard seat to be replaced with-

out disassembling outlet piping or scrubber pipe

connection. Diaphragm actuated valves operate on

30-70 psi (207-483 kPa; 2-5 bar).

Pneumatic Dump
Valves 

See DVU-01069B 

for more details.

Control

Panel

High Level Shutdown Switch

Stainless steel float actuated level switches to alarm

and/or shutdown the equipment.

L1200: 

2” NPT pipe connection; Rated 2000 psi

(13.7MPa) [137bar]; Class 

I

, Division 1. SPDT 

snap-switch standard. DPDT Optional.

All Stainless Steel available.

T

Th

he

e M

Mu

urrp

ph

hy

y G

Ga

as

s C

Co

om

mp

prre

es

ss

so

orr S

Sc

crru

ub

bb

be

err L

Le

ev

ve

ell S

Sy

ys

stte

em

m ((S

SL

LS

S))

The system provides for liq-

uid control in gas scrubber

applications, by dumping liq-

uids to drain and protecting

compressors with a high liq-

uid level switch. Wetted metal

parts are made to survive

constant use in corrosive

environments.

See Bulletin: SLS-04005B for

more details.

DUMP VALVE INSTALLATION