Installation
00-02-0483
page 2 of 4
Basic Operation
As condensate rises in the scrubber, the float
on the L1200NDVOR rises and trips its pneu-
matic valve. The valve opens allowing pres-
sure to enter the dump valve pilot chamber.
Once the pressure enters the pilot chamber it
forces the diaphragm and valve stem forward
thus opening the valve seat (valve open/closed
indicator button pops out) and releasing con-
densate through the valve stem and out the
drain. As the condensate level drops, the
L1200NDVOR pneumatic valve closes to shut
off the pressure to the dump valve causing it to
close.
If for any reason the condensate continues to
rise beyond normal dump levels, model L1200
operates the alarm and/or shuts down the
equipment.
The L1200NDVOR Filter/Regulator and the
MURPHYGAGE
®
help keep the control pres-
sure clean and dry. They also allow the opera-
tor to adjust pressure to recommended levels.
NOTE: Always use clean, dry,
instrument quality gas.
TYPICAL INSTALLATION ON GAS COMPRESSORS
DVU Series Installation
The following describes the “Direct Mounting” method to the
tank wall.
1.
Install the valve so the drain connection is on the bottom. Use
pipe thread sealant on all the connections.
2.
Be sure the unit is screwed tight and does not leak.
3.
Install the piping for the pneumatic input signal into the
1/8 NPT threaded connection of the pressure inlet port (on
top of the diaphragm housing of the DVU).
6.
Install a union between the DVU drain connection and the
condensate out line. Use pipe thread sealant on all the con-
nections.
V
e
s
s
e
l
W
a
ll
Union
Upper Assembly
(removable)
Valve
Union
Pneumatic
Input Signal
Maintenance
Bolt
Valve Indicator
Drain
Connection
Weep Hole
Condensate Out
2-Way (Manual Drain)
Shutoff Valve
Fig. 4
Typical
Dump Valve
Installation
CAUTION:
ALWAYS USE “NON-SPARKING TOOLS”
WHEN GAS IS KNOWN TO BE PRESENT.
WARNING
WARNING
Fig. 3
Scrubber/Separators
Filter/Regulator &
MURPHYGAGE
®
“Instrument
Quality Air/Gas
Supply”
Pneumatic Level Control
Float actuated level snap-acting switch
controls pneumatic pressure to open
and close dump valve.
L1200NDVOR:
Dump Valve Operator,
pressure regulator, and pressure indi-
cating MURPHYGAGE
.
®
Two piece union design with manual valve operator
allows soft plug and hard seat to be replaced with-
out disassembling outlet piping or scrubber pipe
connection. Diaphragm actuated valves operate on
30-70 psi (207-483 kPa; 2-5 bar).
Pneumatic Dump
Valves
See DVU-01069B
for more details.
Control
Panel
High Level Shutdown Switch
Stainless steel float actuated level switches to alarm
and/or shutdown the equipment.
L1200:
2” NPT pipe connection; Rated 2000 psi
(13.7MPa) [137bar]; Class
I
, Division 1. SPDT
snap-switch standard. DPDT Optional.
All Stainless Steel available.
T
Th
he
e M
Mu
urrp
ph
hy
y G
Ga
as
s C
Co
om
mp
prre
es
ss
so
orr S
Sc
crru
ub
bb
be
err L
Le
ev
ve
ell S
Sy
ys
stte
em
m ((S
SL
LS
S))
The system provides for liq-
uid control in gas scrubber
applications, by dumping liq-
uids to drain and protecting
compressors with a high liq-
uid level switch. Wetted metal
parts are made to survive
constant use in corrosive
environments.
See Bulletin: SLS-04005B for
more details.
DUMP VALVE INSTALLATION