background image

Page 2 of 10

AR81.8

CONTEMPORARY WATER COOLERS

 

I N S TA L L AT I O N / M A I N T E N A N C E  I N S T R U C T I O N S

ELECTRIC DRINKING FOUNTAIN

Date: 

04/20/2021

7020-998-001

 

MURDOCK  MFG.  • 

15125  Proctor  Avenue  •  City  of  Industry,  CA  91746  USA 

Phone  800-453-7465  or  626-333-2543  •  Fax  626-855-4860  •  www.murdockmfg.com

Member of

Prior to roughing consult with local, state, and federal codes for proper mounting height. 

 

3

19"

[483]

24"

[610]

31

1

2

"

[800]

17"

[432]

12 "

[305]

36"

[914]

[25]

WALL 

OPENING

WALL 

OPENING

MIN WALL 

OPENING

*33"

[838]

4

7

55

1

2"

[1410]

17"

[432]

52

[1333]

WALL 

OPENING

8

11

10

5

5

FINISHED FLOOR

 III.    STOP VALVE NOT PROVIDED

    I.    ALL  DIMENSIONS  ARE  IN  INCHES 

[MM]

* I I .   D I M E N S I O N   S H O W N   I S   F O R 

RECOMMENDED  ADULT  HEIGHT. 
ADJUST VERTICAL DIMENSIONS AS 
NECESSARY  TO  COMPLY  WITH 
FEDERAL, STATE, & LOCAL CODES

NOTES:

*29"

[737]

CL

1
2"

*79

[2019]

6

1"

2

1

9

AR81.8 SERIES ROUGHING-IN AND DIMENSIONAL DRAWING:

2"

[51]

10

11

CL

GENERAL NOTES:

5.    MOUNTING FRAME ASSEMBLY

3.    VANDAL RESISTANT 

PUSHBUTTON ACTUATOR FOR 
BUBBLER

7.    VENTILATION GRILL

6.    8.0 GPH CHILLER

2.    OPTIONAL -BF LIGATURE 

RESISTANT CUP/BOTTLE FILLER

1.    LIGATURE RESISTANT BUBBLER

4.    VANDAL RESISTANT 

PUSHBUTTON ACTUATOR FOR 
CUP/BOTTLE FILLER

ROUGH-IN PLUMBING NOTES

8.    3/8” OD CHILLER WATER 

INLET

11.   WATER SUPPLY INLET

9.  3/8” OD CHILLER WATER 

OUTLET

10.  1-1/4” SLIP JOINT WASTE  

CONNECTION

*29"

*27

[699]

*27"

[686]

1
2"

1

2"

3

3
8

"

[86]

4"

[102]

51

4

"

[133]

8

CL

2"

[51]

9

11

TOP VIEW 

WALL OPENING

FRONT VIEW

SIDE VIEW

TOP VIEW 

ROUGH-IN

*29"

[737]

53"

[1346]

WALL 

OPENING

FACE 

PLATE

FRAME

WASTE

Содержание AR81.8 Series

Страница 1: ...th these instructions will constitute an abnormal use condition and void the warranty Stainless steel must be protected on job site during construction and must be properly maintained after the water has been introduced into the water cooler or drinking fountain or Murdock s limited warranty is void LIMITED EXPORT WARRANTY One year on parts only Murdock warrants the compressor and hermetically sea...

Страница 2: ... I D I M E N S I O N S H O W N I S F O R RECOMMENDED ADULT HEIGHT ADJUST VERTICAL DIMENSIONS AS NECESSARY TO COMPLY WITH FEDERAL STATE LOCAL CODES NOTES 29 737 C L 1 2 79 2019 6 1 2 1 9 AR81 8 SERIES ROUGHING IN AND DIMENSIONAL DRAWING 2 51 10 11 C L GENERAL NOTES 5 MOUNTING FRAME ASSEMBLY 3 VANDAL RESISTANT PUSHBUTTON ACTUATOR FOR BUBBLER 7 VENTILATION GRILL 6 8 0 GPH CHILLER 2 OPTIONAL BF LIGATU...

Страница 3: ...o strainer or other components 1 Water Supply Service Stop Valve Water Connections and Electrical Connections to be supplied by others in accordance with local codes 1 Read all installation instructions carefully before proceeding 8 This unit must be grounded per the requirements of applicable electrical codes 5 It is common for electrical equipment to be grounded to water lines either within a st...

Страница 4: ...n building water supply and check all connections for leaks 3 Insert and center mounting frame into the rough in blockout with sides top and bottom flange against finished wall Level and secure using mounting hardware provided by the installer Verify if level and shim if necessary 2 Air within the Fountain or the structure supply piping will cause an irregular outlet stream until purged out by inc...

Страница 5: ...01 MURDOCK MFG 15125 Proctor Avenue City of Industry CA 91746 USA Phone 800 453 7465 or 626 333 2543 Fax 626 855 4860 www murdockmfg com Member of Frame Assembly Centered On Opening Fountain Assembly Mounting Tab Upper Removable Vented Access Cover See Details Chiller Unit Lower Removable Access Cover 17 179 53 1346 12 305 Wall Depth AR81 8 SERIES INSTALLATION 29 737 ...

Страница 6: ...r cause water metal content to increase ROUGH IN GENERAL NOTES 1 ALL DIMENSIONS ARE IN INCHES MM 2 ALLOW 4 INCHES 102MM MINIMUM CLEARANCE ON TOP AND FRONT FOR VENTILATION 3 IT IS RECOMMENDED THAT ALL WATER OUTLETS BE CONNECTED DIRECTLY AND NO MORE THAN 7 FEET AWAY FROM THE CHILLER FOR ANYTHING GREATER THAN 7 FEET CHILLED WATER MAY NOT BE EXPOSED UNTIL ALL WATER IN RISER HAS BEEN RELEASED ALL CHILL...

Страница 7: ... Fax 626 855 4860 www murdockmfg com Member of IN OUT IN OUT 2 3 1 TO DRINKING FOUNTAIN 1 OUT IN 4 5 2 3 4 INSULATED 1 4 OD TUBING Y STRAINER PROVIDED ANGLE STOP BY OTHERS CHILLER w 3 8 OD TUBE INLET OUTLET CONNECTIONS OPTIONAL WF1 1500 GALLON WATER FILTER SHOWN WITH NOTE INSULATION TUBING MAY OVERLAP FITTINGS ILLUSTRATIONS MAY SHOW EXPOSED 1 4 OD TUBING FOR CLARITY ONLY 1 2 3 4 5 1 1 4 OD TUBE IN...

Страница 8: ...tting Water test the connection assembly prior to leaving the site to ensure there are no leaks DISCONNECTING THE TUBE Prior to disconnecting the Tube from the Fitting ensure that the Water Line is depressurized Push Collet Square towards the Push In Fitting Body and hold While holding the Collet in pull on the PE Tubing to remove from the Push In Fitting TO CUT TUBE Cut to fit length of 1 4 PE Tu...

Страница 9: ... 0 GPH CHILLER 3 7000 024 001 Y STRAINER ASSY W 1 4 NPT X 3 8 OD 4 7000 021 001 Y STRAINER ASSY W 1 4 NPT 5 0112 002 000 10 32 X 1 2 S S HEX C R BTN HD SCREW 6 7035 430 001 VENT PANEL RECESSED FOUNTAIN 7 7000 065 001 PUSH BUTTON W CARTRIDGE VALVE ASSEMBLY 8 7000 060 000 FLOW REGULATOR CARTRIDGE 0 5 GPM 9 7000 091 001 PUSHBUTTON W HEX ASSY 10 4854 020 001 DECK BUBBLER ASSY LR BPH 11 4854 030 001 NO...

Страница 10: ...D CONNECTION 9 1895 708 000 1 4 OD PUSH IN ELBOW CONNECTION 2 7008 010 199 HOUSING 10 7008 012 199 FRONT PANEL 3 0124 031 000 8 3 8 HEX WASHER HD SLOTTED SCREW 11 7012 803 000 CAPACITOR 4 7008 015 001 CONDENSOR ASSEMBLY 12 7003 250 000 TEMPERATURE CONTROL 5 0332 013 000 1 OD x 7 16 ID FLAT WASHER 13 1895 121 000 1 4 OD PUSH IN CONNECTION 6 7012 150 000 3 32 x 1 5 8 HITCH PIN 14 7003 115 001 EVAPOR...