background image

A181CUSP Series

Barrier Free, Fully Recessed, ADA Fountain & Cuspidor

 

A181400S-CUSP / A181400F-CUSP / A18040000-CUSP / A181400S / A181400F

1.800.591.9360

Technical Assistance Fax: 1.626.855.4894

TECHNICAL ASSISTANCE TOLL FREE TELEPHONE NUMBER: 

 

 

 

 

NOTES TO INSTALLER:

1. Please leave this documentation with the owner of the fixture when finished. 
2. Please read this entire booklet before beginning the installation. 
3. Check your installation for compliance with plumbing, electrical and other applicable codes.

LIMITED WARRANTY - UNITED STATES & CANADA

Murdock warrants that its products are free from defects in material or workmanship under normal use and 
service for a period of one year from date of original shipment or for 18 months after the date of shipment from the 
factory, whichever comes first. Murdock’s liability under this warranty shall be discharged solely by replacement 
or repair of defective material, provided Murdock is notified in writing within one year from date of shipment, 
F.O.B. Industry, California. 

This warranty does not cover installation or labor charges and does not apply to materials, which have been 
damaged by other causes such as mishandling or improper care or abnormal use. The repair or replacement of the 
defective materials shall constitute the sole remedy of the Buyer and the sole remedy of Murdock under this 
warranty. Murdock shall not be liable under any circumstances for incidental, consequential or direct charges 
caused by defects in the materials, or any delay in the repair or replacement thereof.  This warranty is in lieu of all 
other warranties expressed or implied. Product maintenance instructions are issued with each unit and disregard 
or non-compliance with these instructions will constitute an abnormal use condition and void the warranty. 
Stainless steel must be protected on job site during construction and must be properly maintained after the water 
has been introduced into the water cooler or drinking fountain, or Mudock’s limited warranty is void.

LIMITED EXPORT WARRANTY - 

One year on parts only. 

COMPLIES 

WITH

7020-003-001

      

Date: 02/26/16

Test rating conditions are
compliant with ARI 1010.

Federal
Public Law
111-380 
(No Lead)

Member of

 

MURDOCK

15125 Proctor Ave.

City of Industry, CA

91746 U.S.A.

Phone 800-591-9360

626-336-4561

Fax 626-855-4894

 

www.murdockmfg.com

Murdock assumes no responsibility for use of void or 
suspended data. © Copyright Murdock, City of 
Industry, CA Member of  Morris Group International. 
Please visit 

www.murdockmfg.com 

for most 

current specifications.

I N S TA L L AT I O N / M A I N T E N A N C E  I N S T R U C T I O N S

CONTEMPORARY WATER COOLERS

 

I N S TA L L AT I O N / M A I N T E N A N C E  I N S T R U C T I O N S

 DRINKING FOUNTAINS

 

Содержание A18040000-CUSP

Страница 1: ...l constitute the sole remedy of the Buyer and the sole remedy of Murdock under this warranty Murdock shall not be liable under any circumstances for incidental consequential or direct charges caused by defects in the materials or any delay in the repair or replacement thereof This warranty is in lieu of all other warranties expressed or implied Product maintenance instructions are issued with each...

Страница 2: ...ocal codes Adjust vertical dimensions as required to comply with federal state and local codes I N S TA L L AT I O N M A I N T E N A N C E I N S T R U C T I O N S CONTEMPORARY WATER COOLERS I N S TA L L AT I O N M A I N T E N A N C E I N S T R U C T I O N S DRINKING FOUNTAINS A181 CUSP Page 2 of 9 02 26 16 7020 003 001 MURDOCK MFG 15125 Proctor Avenue City of Industry CA 91746 USA Phone 800 453 74...

Страница 3: ...nts are assembled to the fixture that are not approved by Acorn Engineering Company 5 Fixtures operates within water pressure range of 20 to 105 psig Acorn Engineering Company will not warranty fixtures damaged when connected to supply lines with flow pressure lower than 20 psig or higher than 105 psig A pressure regulator must be furnished by others on supply line if inlet pressure is greater tha...

Страница 4: ...ed to pass through the tabs on both units and into the tabs of the lower frame bracket containing the captive nuts Tighten the screws to pull the Fountain Cuspidor flush with the wall 7 Install water supply and drain as required per Figure A rough in dimensions 8 Thoroughly flush the supply lines connect water supply to the Cuspidor 9 Make up 1 1 4 OD P Trap waste connection UPPER MOUNTING BRACKET...

Страница 5: ...r to locate your local representative is 1 800 591 9360 CLEANING MAINTENANCE GUIDE 1 Periodically remove access panels and clean out in line strainer 2 Do NOT use harsh chemicals abrasive or petroleum based cleaners Use of these will void the Acorn warranty 3 Exterior panels can be cleaned using mild household detergents or warm soapy water Extra care must be used cleaning chrome plated items and ...

Страница 6: ...h in fitting TO CUT TUBE Cut to fit length of 1 4 PE tubing and remove any burrs or sharp edges Ensure that the outside diameter is free from score marks Tube ends should be square INSERTING THE TUBE 1 Firmly and fully insert the tubing end into the push in fitting up to the tube stop located approximately deep COLLET COLLET O RING O RING TUBE STOP COLLET COLLET COLLET I N S TA L L AT I O N M A I ...

Страница 7: ... L L AT I O N M A I N T E N A N C E I N S T R U C T I O N S DRINKING FOUNTAINS A181 CUSP Page 7 of 9 02 26 16 7020 003 001 MURDOCK MFG 15125 Proctor Avenue City of Industry CA 91746 USA Phone 800 453 7465 or 626 333 2543 Fax 626 855 4860 www murdockmfg com Member of 2 4 3 5 6 9 10 20 11 12 13 14 15 16 19 22 23 24 18 17 8 7 1 21 ...

Страница 8: ...GE 0 5 GPM 24 7000 050 001 VALVE ASSEMBLY 1 ITEM PART NUMBER DESCRIPTION 7000 012 001 STAINLESS STEEL BUBBLER ASSEMBLY 7000 099 002 LOW FLOW FLEX BUBBLER GRAY 2 7035 128 199 UPPER MOUNTING BRACKET 3 N A N A 4 N A N A 5 N A N A 6 N A N A 7 N A N A 8 N A N A 9 4926 055 001 GRID STRAINER w CLOSE ELL ASSY 10 0316 020 000 CAPTIVE NUT 11 0331 004 000 10 FLAT WASHER 12 0321 011 000 10 STAR WASHER 13 0116...

Страница 9: ...ORT ADA 15 0279 002 000 8 32 SOCKET CAP BUTTON HD SCREW 3 4 LG 16 0322 001 000 8 PLATED STAR LOCK WASHER EXTERNAL 17 7002 125 001 WELDED PUSHBUTTON AIR TROL VALVE ASSY 18 7002 125 002 PUSHBUTTON ASSY AIR VALVE 19 7035 306 001 BRACKET FRAME LWR FTN ONLY ADA 20 7000 415 000 SELF RETAINING J NUT 21 N A N A 22 N A N A 23 N A N A 24 N A N A A181 CUSP Page 9 of 9 02 26 16 7020 003 001 MURDOCK MFG 15125 ...

Отзывы: