background image

 

IMPORTANT:

1.   Water supply is 3/8” Outside Diameter Copper Tube. Waste is 1-1/4” Outside Diameter.

2.   Completely flush supply lines of all foreign debris before connecting to fixture. Drinking Fountain designed to not 

affect taste, odor, color, or sediment. Optional water filter (WF1) is available should any of these problems arise 
from the water supply.

3.   Do NOT solder Copper Tube when inserted into the Coupler as damage to the O-Ring will result.

4.   All burrs must be removed from outside of cut tubes before inserting into Coupler or other components.

5

.   WARNING: Warranty is voided if installatio

n is not made following current Murdock Mfg. installation instructions 

and if components are assembled to the fixture that is not approved by Murdock Mfg.

6.   Fixture operates within water pressure range of 20 to 105 PSIG (138 to 724 kPa). Murdock Mfg. will not warranty 

fixtures damaged when connected to supply lines with flow pressure lower than 20 PSIG (138 kPa) or higher than 
105 PSIG (724 kPa). A pressure regulator must be furnished by others on supply line if inlet pressure is greater 
than 105 PSIG (724 kPa).

7. 

Per UPC 609.10

-

 All building water supply systems in which quick acting valves are installed shall be provided with 

devices to absorb the hammer caused by high pressure resulting from the quick closing of the valve. These 
pressure-absorbing devices shall be approved mechanical devices. Water pressure-absorbing devices will be 
installed as close as possible to the quick closing valve.

INSTALLATION:

1.   Mount Hanger Bracket to wall horizontally level as shown in Roughing-In and Dimensional Drawing. Note: Adjust 

height of bracket if Bubbler outlet height is required to vary from that shown. 
WARNING: Hanger Bracket MUST be securely anchored to wall with fasteners sufficient to support 3 times the 
weight of Drinking Fountain. If wall can not provide adequate support, order and install optional fixture support 
carrier.

2.   Remove the Bottom Cover from the Drinking Fountain and set aside in a safe place. Save the Screws in a secure 

location for re-use in later stages of installation.

3.   

START UP:

1.   Before connecting water supply and assembling Bottom Cover to Drinking Fountain, but after thoroughly flushing 

the supply line and connecting it to the fixture, turn on building water supply and check all connections for leaks.

2.   Air within the Drinking Fountain system or the structure supply piping will cause an irregular Bubbler outlet stream 

until purged out by incoming water. Covering the Bubbler with a clean cup (or similar object) is recommended when 
first activating Drinking Fountain to prevent excessive splashing. Depress the Pushbutton until steady water stream 
is achieved.

3.   If water flow requires adjustment, insert a Slotted Narrow Blade Screwdriver in the hole centered on the underside 

of the fixture in the knee clearance area up to the Flow Regulator. Turning clockwise will increase flow and turning 
counterclockwise will decrease flow.

4.   Recheck all water and drain connections with water flowing through system.

5.   Assemble Bottom Cover to Drinking Fountain with Screws furnished. 

Hang the Drinking Fountain on the Hanger Brackets ensuring the Bracket Tabs engage AND seat in the slots in the 

back of the Drinking Fountain. Verify Drinking Fountain are level, left to right AND front to back from bottom of unit. 
NOTE: The Bubbler stream may be adversely affected if units are not square and level. Bottom of units and 
Louvers should be used as reference to verify unit is square and plumb.

4.   Anchor the Drinking Fountain to the wall at the lower mounting points in each Back Panel. Shim lower mounting 

points to level unit if necessary.

5.   Thoroughly flush the 3/8” O.D. supply line and then connect Drinking Fountain to Water Supply Angle Stop Valve (by 

others) with supplied 3/8” O.D. Copper Tube.

6.   Use supplied Flexible Hose and Clamps to connect Waste Tailpiece from the upper unit to the Waste Tailpiece of 

lower unit and then make up 1-1/4” O.D. P-Trap Waste Connection. Waste P-Trap by others.

 

I N S TA L L AT I O N / M A I N T E N A N C E  I N S T R U C T I O N S

CONTEMPORARY WATER COOLERS

 

I N S TA L L AT I O N / M A I N T E N A N C E  I N S T R U C T I O N S

 DRINKING FOUNTAIN

 

 

A172-SO

Page 3 of 10

Revised: 

12/20/17

7020-961-001

MURDOCK  MFG.  • 

15125  Proctor  Avenue  •  City  of  Industry,  CA  91746  USA 

Phone  800-453-7465  or  626-333-2543  •  Fax  626-855-4860  •  www.murdockmfg.com

Member of

Содержание A172-SO Series

Страница 1: ...arged solely by replacement or repair of defective material provided Murdock is notified in writing within one year from date of shipment F O B Industry California This warranty does not cover installation or labor charges and does not apply to materials which have been damaged by other causes such as mishandling or improper care or abnormal use The repair or replacement of the defective materials...

Страница 2: ...OCK MFG 15125 Proctor Avenue City of Industry CA 91746 USA Phone 800 453 7465 or 626 333 2543 Fax 626 855 4860 www murdockmfg com Member of 1 1 4 32 P TRAP BY OTHERS 71 4 184 23 4 70 181 2 470 13 8 35 12 305 33 838 6 152 217 8 556 D 185 8 473 E 157 8 403 77 8 200 41 4 108 21 4 57 C 51 4 133 165 8 65 8 168 A 3 8 NCT Supply Inlet B Waste Outlet for 1 1 4 P Trap by others C Electrical Service Rough D...

Страница 3: ...P 1 Before connecting water supply and assembling Bottom Cover to Drinking Fountain but after thoroughly flushing the supply line and connecting it to the fixture turn on building water supply and check all connections for leaks 2 Air within the Drinking Fountain system or the structure supply piping will cause an irregular Bubbler outlet stream until purged out by incoming water Covering the Bubb...

Страница 4: ...o the highest setting using a Flat Head Screwdriver and turning clockwise Check if water drip continues if it is no longer dripping turn Screwdriver counter clockwise until you have desired flow rate Assure that Retaining Nut is tighten to Valve Assembly 25 in lb 2825 mNm torque is required If issue still continues after adjusting flow and tightening Retainer Nut replacement of the Flow Regulator ...

Страница 5: ...ainer 2 DO NOT use harsh chemicals abrasive or petroleum based cleaners Use of these will void the Murdock warranty 3 Exterior panels can be cleaned using mild household detergents or warm soapy water Extra care must be used cleaning chrome plated items and mirror finished stainless steel They can scratch easily and should only be cleaned using a clean soft cloth and mild soap with water or a mild...

Страница 6: ...ember of OPTIONAL WF1 WATER FILTER See the following page for models with WF1 Water Filter A172 SO WF1 ITEM PART NUMBER DESCRIPTION 1 7012 311 000 WF1 FILTER 1500 GALLON 2 7003 010 002 FILTER WELD ASSEMBLY 3 7012 055 000 FOAM PIPE INSULATION 3 8 I D x 1 4 THK 4 2169 000 000 1 4 O D LLDPE TUBING BLUE 5 0124 031 000 8 ZINC HEX SHEET METAL SCREW 6 0124 010 000 10 PHILLIPS ROUND HEAD 7 1895 709 000 EL...

Страница 7: ...1 WATER FILTER INSTALLATION 1 Remove the Bottom Housing and turn off unit water supply 2 With the Filter Assembly secured on the unit hold the Cap firmly turn the Replaceable Cartridge Filter counterclockwise to remove 3 Remove and replace the Cartridge turning clockwise to secure 4 Turn on Water and check for leaks Important Flush 5 gallons of water through the Filter before allowing fixture use ...

Страница 8: ...n Fitting TO CUT TUBE Cut to fit length of 1 4 PE Tubing and remove any burrs or sharp edges Ensure that the outside diameter is free from score marks Tube ends should be square INSERTING THE TUBE 1 Firmly and fully insert the Tubing End into the Push In Fitting up to the Tube Stop located approximately deep COLLET COLLET O RING O RING TUBE STOP COLLET COLLET COLLET I N S TA L L AT I O N M A I N T...

Страница 9: ... to drawing above All 1 4 O D Plastic tubing 21 must be insulated with 22 foam insulation I N S TA L L AT I O N M A I N T E N A N C E I N S T R U C T I O N S CONTEMPORARY WATER COOLERS I N S TA L L AT I O N M A I N T E N A N C E I N S T R U C T I O N S DRINKING FOUNTAIN A172 SO Page 9 of 10 Revised 12 20 17 7020 961 001 MURDOCK MFG 15125 Proctor Avenue City of Industry CA 91746 USA Phone 800 453 7...

Страница 10: ...LOTTED HEX WASHER HD SCREW 17 1895 121 000 SUPPLY INLET CONNECTION 18 1895 710 000 1 4 OD PUSH IN TEE CONNECTION 7003 819 020 FILLER PLATE GRANITE 7003 825 199 FILLER PLATE STAINLESS STEEL 20 0124 050 000 8 x 3 8 LG PHILLIPS PAN HEAD SCREW 21 2169 000 000 1 4 O D TUBING 22 7012 055 000 TUBE INSULATION 23 7003 093 001 FLOW RESTRICTOR LOW FLOW BUBBLER ONLY 24 7003 014 199 HANGER BRACKET 25 0124 056 ...

Отзывы: