background image

TROUBLE SHOOTING:

IMPORTANT: BEFORE MAKING ANY OF THE REPAIRS LISTED, MAKE SURE THE WATER COOLER IS 
DISCONNECTED FROM THE ELECTRICAL SUPPLY AND THE WATER SUPPLY VALVE IS SHUT OFF.

1. Adjustments 

a. Cartridge – The water flow can be adjusted through the Pushbutton using a Straight Blade

 Screwdriver and turning clockwise to increase flow and counterclockwise to decrease flow. 

b. Cold Water Thermostat – The water temperature can be adjusted using a Slotted Screwdriver

 and turning clockwise to make colder and counterclockwise to make warmer. 

c. Bubbler Stream – Bubbler can be rotated slightly to direct the stream backwards or forwards.

 Adjust the stream to minimize splashing. Splashing may occur from Bubbler Stream if the unit
 is not level. Shim lower mounting points, if necessary, to level Drinking Fountain.

2. Restricted Or No Water Flow 

a. Ensure Water Supply Service Stop Valve is fully open. 
b. Verify minimum 20 PSIG (138 kPa) supply line flow pressure. 
c. Check for twists or kinks in Bubbler Tubing. 
d. Check the Water Inlet Strainer. Sediment from the main supply can get trapped in the

 Screen along with installation materials such as Pipe Dope and Flux. The screen should
 be cleaned and checked on a regular basis and replace if needed.
 

NOTE: STRAINER SCREEN MUST BE IN PLACE FOR WATER TO FLOW.

e. The Cartridge Valve located in the Water Control Assembly or Bubbler can also become

 clogged with foreign material. The Cartridge Valve can only be replaced and not repaired.

f. Check flow adjustment. See start up note #3. 
g. Flow control in Solenoid Valve Outlet Elbow clogged remove & clean.
h. No power to Power Supply connections, loose or wires cut.

3. Water Drip Or Will Not Shut Off:

a. Remove Pushbutton, adjust flow regulator to the highest setting using a 

 Flat Head Screwdriver and turning clockwise. Check if water drip continues, if it is no longer 
 dripping turn Screwdriver counter-clockwise until you have desired flow rate. Assure that 
 Retaining Nut is tighten to Valve Assembly, 25 in-lb (2825 mNm) torque is required. If issue still continues after 
 adjusting flow and tightening Retainer Nut, replacement of the Flow Regulator Cartridge will be 
 required.

b. Replace Valve Cartridge.

4. If light within sensor does not flash once when user is within range:

a. Verify 120VAC input & 9VDC output transformer output 9VDC.
b. Replace defective transformer.
c. Transformer polarity crossed. Replace transformer, sensor may be damaged and also need replacement.
d. Sensor in “Security Mode” after 30 seconds of consistent detection. Remove source of detection and wait 30

seconds before checking.

e. Sensor is picking up a highly reflective surface. Eliminate cause of reflection and wait 30 seconds before

checking.

5. If light within sensor lens flashes once when the user is within range:

a. Repair bad connection from Sensor to Solenoid.
b. There is debris or scale in the Solenoid Assembly. Remove Solenoid, pull out Plunger and Spring. Clean

with scale remover solution.

c. There is debris or scale in the center or two holes in convolution of the Water Diaphragm. Remove and

clean.

IMPORTANT : ASSUREZ-VOUS QUE LA FONTAINE D'EAU POTABLE RÉFRIGÉRÉE SOIT DÉBRANCHÉE DE LA 
PRISE DE COURANT MURALE ET QUE LE ROBINET D'ALIMENTATION D'EAU SOIT FRMÉ AVANT 
D'EFFECTUER LES RÉPARATIONS NÉCESSAIRES.

 

I N S TA L L AT I O N / M A I N T E N A N C E  I N S T R U C T I O N S

CONTEMPORARY WATER COOLERS

 

I N S TA L L AT I O N / M A I N T E N A N C E  I N S T R U C T I O N S

 DRINKING FOUNTAIN

 

 

A172-SO

Page 4 of 10

Revised: 

12/20/17

7020-961-001

MURDOCK  MFG.  • 

15125  Proctor  Avenue  •  City  of  Industry,  CA  91746  USA 

Phone  800-453-7465  or  626-333-2543  •  Fax  626-855-4860  •  www.murdockmfg.com

Member of

Содержание A172-SO Series

Страница 1: ...arged solely by replacement or repair of defective material provided Murdock is notified in writing within one year from date of shipment F O B Industry California This warranty does not cover installation or labor charges and does not apply to materials which have been damaged by other causes such as mishandling or improper care or abnormal use The repair or replacement of the defective materials...

Страница 2: ...OCK MFG 15125 Proctor Avenue City of Industry CA 91746 USA Phone 800 453 7465 or 626 333 2543 Fax 626 855 4860 www murdockmfg com Member of 1 1 4 32 P TRAP BY OTHERS 71 4 184 23 4 70 181 2 470 13 8 35 12 305 33 838 6 152 217 8 556 D 185 8 473 E 157 8 403 77 8 200 41 4 108 21 4 57 C 51 4 133 165 8 65 8 168 A 3 8 NCT Supply Inlet B Waste Outlet for 1 1 4 P Trap by others C Electrical Service Rough D...

Страница 3: ...P 1 Before connecting water supply and assembling Bottom Cover to Drinking Fountain but after thoroughly flushing the supply line and connecting it to the fixture turn on building water supply and check all connections for leaks 2 Air within the Drinking Fountain system or the structure supply piping will cause an irregular Bubbler outlet stream until purged out by incoming water Covering the Bubb...

Страница 4: ...o the highest setting using a Flat Head Screwdriver and turning clockwise Check if water drip continues if it is no longer dripping turn Screwdriver counter clockwise until you have desired flow rate Assure that Retaining Nut is tighten to Valve Assembly 25 in lb 2825 mNm torque is required If issue still continues after adjusting flow and tightening Retainer Nut replacement of the Flow Regulator ...

Страница 5: ...ainer 2 DO NOT use harsh chemicals abrasive or petroleum based cleaners Use of these will void the Murdock warranty 3 Exterior panels can be cleaned using mild household detergents or warm soapy water Extra care must be used cleaning chrome plated items and mirror finished stainless steel They can scratch easily and should only be cleaned using a clean soft cloth and mild soap with water or a mild...

Страница 6: ...ember of OPTIONAL WF1 WATER FILTER See the following page for models with WF1 Water Filter A172 SO WF1 ITEM PART NUMBER DESCRIPTION 1 7012 311 000 WF1 FILTER 1500 GALLON 2 7003 010 002 FILTER WELD ASSEMBLY 3 7012 055 000 FOAM PIPE INSULATION 3 8 I D x 1 4 THK 4 2169 000 000 1 4 O D LLDPE TUBING BLUE 5 0124 031 000 8 ZINC HEX SHEET METAL SCREW 6 0124 010 000 10 PHILLIPS ROUND HEAD 7 1895 709 000 EL...

Страница 7: ...1 WATER FILTER INSTALLATION 1 Remove the Bottom Housing and turn off unit water supply 2 With the Filter Assembly secured on the unit hold the Cap firmly turn the Replaceable Cartridge Filter counterclockwise to remove 3 Remove and replace the Cartridge turning clockwise to secure 4 Turn on Water and check for leaks Important Flush 5 gallons of water through the Filter before allowing fixture use ...

Страница 8: ...n Fitting TO CUT TUBE Cut to fit length of 1 4 PE Tubing and remove any burrs or sharp edges Ensure that the outside diameter is free from score marks Tube ends should be square INSERTING THE TUBE 1 Firmly and fully insert the Tubing End into the Push In Fitting up to the Tube Stop located approximately deep COLLET COLLET O RING O RING TUBE STOP COLLET COLLET COLLET I N S TA L L AT I O N M A I N T...

Страница 9: ... to drawing above All 1 4 O D Plastic tubing 21 must be insulated with 22 foam insulation I N S TA L L AT I O N M A I N T E N A N C E I N S T R U C T I O N S CONTEMPORARY WATER COOLERS I N S TA L L AT I O N M A I N T E N A N C E I N S T R U C T I O N S DRINKING FOUNTAIN A172 SO Page 9 of 10 Revised 12 20 17 7020 961 001 MURDOCK MFG 15125 Proctor Avenue City of Industry CA 91746 USA Phone 800 453 7...

Страница 10: ...LOTTED HEX WASHER HD SCREW 17 1895 121 000 SUPPLY INLET CONNECTION 18 1895 710 000 1 4 OD PUSH IN TEE CONNECTION 7003 819 020 FILLER PLATE GRANITE 7003 825 199 FILLER PLATE STAINLESS STEEL 20 0124 050 000 8 x 3 8 LG PHILLIPS PAN HEAD SCREW 21 2169 000 000 1 4 O D TUBING 22 7012 055 000 TUBE INSULATION 23 7003 093 001 FLOW RESTRICTOR LOW FLOW BUBBLER ONLY 24 7003 014 199 HANGER BRACKET 25 0124 056 ...

Отзывы: