NOTES:
See next page for Alternative Mounting of units, roughing-in and dimensional drawing.
2. Provide clear floor space as required. Adjust vertical dimensions as required to comply with federal, state, and
local codes.
1. Dimensions shown for ADA compliant installation. For Child ADA 2010 compliant parallel approach installation,
decrease height of * dimensions by 2-3/4".
ROUGHING-IN AND DIMENSIONAL DRAWING
Prior to roughing consult with local, state, and federal codes for proper mounting height.
IMPORTANT
A dielectric coupling must be used to connect the water cooler to the water supply . A nonmetallic coupler is
furnished with this water cooler to meet this requirement.
NOTICE
A172.8-UG-BFS SERIES REFRIGERATED BI-LEVEL WALL MOUNTED WATER COOLER
NOTE:
there are no mounting changes to be made for A172-UG-VR-BFS and A172-UG-SO-BFS models
.
This fixture is intended to dispense water that has been lowered in temperature, but otherwise remains
unchanged by the materials in the water cooler. It is common for electrical equipment to be grounded to water
lines either within a structure or away from it. Every attempt should be made to prevent this kind of grounding
from generating electrical feedback into the water cooler creating electrolysis. Electrolysis will cause a metallic
taste or cause water metal content to increase.
A172.8-UG-VR-D1-BFS
Page 2 of 17
Revised:
02/10/21
7020-986-001
MURDOCK MFG. •
15125 Proctor Avenue • City of Industry, CA 91746 USA
Phone 800-453-7465 or 626-333-2543 • Fax 626-855-4860 • www.murdockmfg.com
Member of
CONTEMPORARY WATER COOLERS
I N S TA L L AT I O N / M A I N T E N A N C E I N S T R U C T I O N S
WATER COOLERS
1-1/4" [32] O.D.
TAILPIECE FOR
P-TRAP BY
OTHERS
1
3
8
"
[35]
6"
[151]
12"
[305]
*33"
[838]
6"
[152]
D
E
C
B
A
GENERAL NOTES:
1. ALL DIMENSIONS ARE IN INCHES [MM]
2. ALLOW 4 INCHES [102MM] MINIMUM CLEARANCE PER SIDE FOR
VENTILATION
3. DIMENSIONS SHOWN ARE FOR ADA ADULT HEIGHT. ADJUST
VERTICAL DIMENSIONS AS NECESSARY TO COMPLY WITH
FEDERAL, STATE & LOCAL CODES
4. STOP VALVE, P-TRAP & ELECTRICAL OUTLET NOT SUPPLIED
5. IMPORTANT: COOLERS MUST BE ATTACHED TO WALL WITH
APPROPRIATE ANCHOR SCREWS, PROVIDED BY INSTALLER
A. 3/8" O.D. SUPPLY INLET
B. WASTE OUTLET FOR P-TRAP BY OTHERS FOR PROVIDED
1-1/4" O.D. TAILPIECE
C. ELECTRICAL SERVICE ROUGH (IF REQUIRED)
D. Ø3/8" HANGER BRACKET PUNCHING, 6 PLACES ON EACH
FIXTURE FOR ANCHORING HARDWARE BY OTHERS
E. Ø1/4" PUNCHING, 2 PLACES ON EACH FIXTURE FOR
ANCHORING HARDWARE, BY OTHERS
F. PUSHBUTTON CARTRIDGE OR SENSOR ASSEMBLY
G. Ø3/8" BOTTLE FILLER MOUNTING BRACKET PUNCHING, 2 PLACES
FIXTURE FOR ANCHORING HARDWARE BY OTHERS
H. Ø1/15" BOTTLE FILER MOUNTING BRACKET PUNCHING, 2 PLACES
FIXTURE FOR ANCHORING HARDWARE BY OTHERS
*
2"
[51]
3
3
4
"
[95]
*15
7
8
"
[403]
*17
7
8
"
[454]
1
3
8
"
[35]
3"
[76]
*30
5
8
"
[778]
2"
[51]
6"
[152]
2"
[51]
*36
5
8
"
[930]
7
7
8
"
[200]
TYP
6
3
8
"
[163]
12
3
4
"
[324]
4
1
4
"
[108]
D
E
F
18
5
8
"
[473]
2
3
4
"
[70]
10
5
16
"
[262]
6"
[152]
G
H