background image

2.   Remove the bottom cover from the water cooler and set aside in a safe place. Save the screws in a secure 

location for re-use in later stages of installation.

INSTALLATION:

1.   Mount hanger bracket to wall horizontally level as shown in Roughing-In and Dimensional Drawing. Note: 

Adjust height of bracket if bubbler outlet height is required to vary from that shown. 
Hanger Bracket MUST be securely anchored to wall with fasteners sufficient to support 3 times the weight of 
cooler. If wall can not provide adequate support, order and install optional fixture support carrier.

3.   

Hang the water cooler on the hanger bracket ensuring the bracket tabs engage AND seat in the slots in the 

back of the water cooler. Verify if water cooler is level, left to right AND front to back from bottom of unit. 

NOTE: The bubbler stream may be adversely affected if units are not square and level. Bottom of units and 
louvers should be used as reference to verify unit is square and plumb.

6.   Thoroughly flush the 3/8” O.D. supply line and then connect water cooler to water supply angle stop valve (by 

others) with supplied 3/8” O.D. copper tube.

5.   Outlet tube from evaporator has an in-line tee with a tube going to the refrigerated unit's valve and the "TEE" 

not connected. Connect the loose supply tube from refrigerated unit to the "TEE".

7.   Use supplied flexible hose and clamps to connect waste tailpiece from the upper unit to the waste tailpiece of 

lower unit and then make up 1-1/4” O.D. p-trap waste connection. Waste p-trap by others.

START UP:

4.   Anchor the water coolers to the wall at the lower mounting points in each back panel. Shim lower mounting 

points to level unit if necessary.

6.   Plug water cooler in to electrical outlet and make sure unit begins to function.

5.   With power still NOT connected, carefully manually rotate cooling fan to insure proper clearance and free fan 

action.

2.   Air within the water cooler system or the structure supply piping will cause an irregular bubbler outlet stream 

until purged out by incoming water. Covering the bubbler with a clean cup (or similar object) is recommended 
when first activating water cooler to prevent excessive splashing. Depress the pushbutton until steady water 
stream is achieved.

7.   Assemble bottom cover to water cooler with screws furnished. 

3.   If water flow requires adjustment, insert a slotted narrow blade screwdriver through the hole centered on the 

pushbutton to the flow regulator. Turning clockwise will increase flow and turning counterclockwise will 
decrease flow.

1.   Before connecting power supply and assembling bottom cover to water cooler, but after thoroughly flushing 

the supply line and connecting it to the fixture, turn on building water supply and check all connections for 
leaks.

4.   Recheck all water and drain connections with water flowing through system.

 

A311.8

Page 3 of 9

Revised: 

09/01/20

7020-919-001

MURDOCK  MFG.  • 

15125  Proctor  Avenue  •  City  of  Industry,  CA  91746  USA 

Phone  800-453-7465  or  626-333-2543  •  Fax  626-855-4860  •  www.murdockmfg.com

Member of

 

CONTEMPORARY WATER COOLERS

 

I N S TA L L AT I O N / M A I N T E N A N C E  I N S T R U C T I O N S

 WATER COOLERS

 

Содержание A1311408F

Страница 1: ...ch unit and disregard or non compliance with these instructions will constitute an abnormal use condition and void the warranty Stainless steel must be protected on job site during construction and must be properly maintained after the water has been introduced into the water cooler or drinking fountain or Murdock s limited warranty is void LIMITED EXPORT WARRANTY One year on parts only LIMITED WA...

Страница 2: ...etallic coupler is furnished with this water cooler to meet this requirement A311 8 Page 2 of 9 Revised 09 01 20 7020 919 001 MURDOCK MFG 15125 Proctor Avenue City of Industry CA 91746 USA Phone 800 453 7465 or 626 333 2543 Fax 626 855 4860 www murdockmfg com Member of AIR FLOW GENERAL NOTES 1 ALL DIMENSIONS ARE IN INCHES MM 2 ALLOW 4 INCHES 102 MM MINIMUM CLEARANCE PER SIDE FOR VENTILATION 3 DIME...

Страница 3: ... 1 4 O D p trap waste connection Waste p trap by others START UP 4 Anchor the water coolers to the wall at the lower mounting points in each back panel Shim lower mounting points to level unit if necessary 6 Plug water cooler in to electrical outlet and make sure unit begins to function 5 With power still NOT connected carefully manually rotate cooling fan to insure proper clearance and free fan a...

Страница 4: ...densation 12 Per UPC 609 10 All building water supply systems in which quick acting valves are installed shall be provided with devices to absorb the hammer caused by high pressure resulting from the quick closing of the valve These pressure absorbing devices shall be approved mechanical devices Water pressure absorbing devices will be installed as close as possible to the quick closing valve 2 Pr...

Страница 5: ...g condition in which the water will become frozen inside the evaporator coil This indicates a refrigeration problem or thermostat failure in which case the water cooler needs to be checked by a qualified technician 2 Compressor Does Not Run a Check the electrical receptacle for power and correct voltage The incoming voltage must be within 10 of the rated voltage on the serial nameplate b The cold ...

Страница 6: ...ess steel They can scratch easily and should only be cleaned using a clean soft cloth and mild soap with water or a mild glass cleaner CARTRIDGE VALVE PARTS BREAKDOWN STANDARD CARTRIDGE VALVE PARTS BREAKDOWN ITEM PART NUMBER DESCRIPTION 1 7000 050 001 Valve Cartridge Assembly 2 7000 060 000 Valve Cartridge 3 7000 053 199 Jam Nut ITEM PART NUMBER DESCRIPTION 1 2 3 7000 000 001 7000 060 001 0401 015...

Страница 7: ...e PE tubing to remove from the push in fitting TO CUT TUBE Cut to fit length of 1 4 PE tubing and remove any burrs or sharp edges Ensure that the outside diameter is free from score marks Tube ends should be square 1 Firmly and fully insert the tubing end into the push in fitting up to the tube stop located approximately deep INSERTING THE TUBE COLLET COLLET O RING O RING TUBE STOP COLLET COLLET C...

Страница 8: ... 15 28 27 18 28 27 18 NOTE Flow Restrictor Only Available With Low Flow Bubbler 29 A311 8 Page 8 of 9 Revised 09 01 20 7020 919 001 MURDOCK MFG 15125 Proctor Avenue City of Industry CA 91746 USA Phone 800 453 7465 or 626 333 2543 Fax 626 855 4860 www murdockmfg com Member of CONTEMPORARY WATER COOLERS I N S TA L L AT I O N M A I N T E N A N C E I N S T R U C T I O N S WATER COOLERS ...

Страница 9: ... 000 FAN MOTOR 7012 062 001 FAN MOTOR 220V 7005 506 020 SIDE PANEL GRAY 7005 511 199 SIDE PANEL STAINLESS STEEL 0124 056 000 8 x 3 8 LONG PHILLIP PH SHEET METAL SCREW 7003 250 000 COLD CONTROL 7003 120 001 EVAPORATOR ASSEMBLY 7004 407 199 BACK PLATE 7004 408 199 HANGER BRACKET 7000 021 001 Y STRAINER 7000 032 001 DRAIN TUBE ASSEMBLY 7000 005 199 DRAIN ADAPTER 7000 006 000 FLAT DRAIN ADAPTER GASKET...

Отзывы: