© Munters AB, 2020
93
10
Temperature Settings
•
•
Configuring the Temperature Curve
•
10.1
What is the Temperature Curve
As animals grow, the required air temperature changes. Trio enables setting up a temperature chart in
which you set the target temperatures for (up to) 10 days in the growth cycle. Target temperature is the
ideal temperature for pigs at that growth day. After defining the target temperatures and growth days,
Trio creates a curve in which the target temperature automatically, gradually adjusts itself. As the growth
days increase, the target temperature gradually decreases to the next setting.
For example, if on day 1 the target temperature is 95° F and on day 5 the target temperature is 86° F,
Trio adjusts the target temperature on days 2 to 4 so that it approaches the day 5 setting.
Figure 29: Temperature Curve Example
In addition the Temperature Curve has secondary functions:
•
Defines when heating begins in cases where the actual temperature drops below the target
temperature (Heat).
•
Defines when heating turns off.
•
Defines when an alarm is sent when temperatures are too low (Low Alarm)
•
Defines when an alarm is sent when temperatures are too high (High Alarm)
Содержание Rotem Trio 20
Страница 20: ... Munters AB 2020 20 Figure 6 Relay and port numbering ...
Страница 44: ... Munters AB 2020 44 ...
Страница 99: ... Munters AB 2020 99 Refer to Tunnel Ventilation page 123 for more details ...
Страница 110: ... Munters AB 2020 110 4 Click the fan in the upper right Both fans turn blue 5 Define fans as required ...
Страница 141: ... Munters AB 2020 141 If an outside temperature sensor is enabled map timers to it if required ...
Страница 160: ... Munters AB 2020 160 23 3 2TRIO 20 CONTAINER SPARE PARTS ...
Страница 162: ... Munters AB 2020 162 23 3 3TRIO 20 DOOR CARDS SPARE PARTS ...
Страница 164: ... Munters AB 2020 164 23 3 4TRIO 20 MAIN CONTAINER SPARE PARTS ...
Страница 170: ... Munters AB 2020 170 Card Description Munters Ordering Number TUBES AND FILTERS FOR RPS NO RPS CARD 999 99 00503 ...
Страница 186: ... Munters AB 2020 186 Figure 33 Relay and port numbering 26 2 3POWER Figure 34 Power ports ...
Страница 199: ... Munters AB 2020 199 2 Insert and secure the SMA connector ...
Страница 202: ... Munters AB 2020 202 example only ...