The heater must be operated only by properly trained personnel. The manufacturer’s instructions must be followed. 

 

The heater must be installed and operated so that people are not exposed to dangers deriving from exhaust gases, from 

the hot air flow and in such a way that no fire risks exist. 

 

It is forbidden to  install the heater in the surroundings of flammable materials,  combustible products, or in explosive 

atmosphere.  

 

When an 

indirect-fired

 heater connected to a flue pipe is used in a closed room, provide a minimum opening area of 1 

ft³ per US gallon capacity at the unit level. 

 

When a 

direct-fired

 heater - or an 

indirect-fired

 heater 

not 

connected to a flue pipe - is used in a closed room, provide 

a minimum opening  area of 3 ft

2

 per US gallon  capacity at the  unit level and a continuous, natural air circulation  through 

windows and doors.  
For the use of the heater the general and special  fire safety regulations in force in all fields of applications must be followed. 
In any  case the following minimum  safety  clearances from  materials or objects in the surroundings of  the heater must  be 
assured: 
 
 

 

 

Side:    

 

2 ft 

(610 mm) 

 

 

 

Air inlet side:    

2 ft 

(610 mm) 

 

 

 

Top:     

 

5 ft 

(1525 mm) 

 

 

 

Hot air outlet side:   

10 ft 

(3050 mm)  

 

 

 

Floor:   

 

0 ft 

(0 mm) 

 

 

 

Flue pipe: 

 

3 ft 

(915 mm) 

 

 

Floors and ceilings must be made of fireproof materials in the place where the heater is operated. 

 

The air inlet and outlet must never be blocked for any reason. 

 

Install the heater on a flat, level floor in a steady position. 

 

It is forbidden to connect direct-fired heaters to air ducts. 

 

4.2 Maintenance and checks 
 

 

Depending on the operational conditions, usually every year, the heater should be checked by qualified personnel. 

Prior to start-up, the user must check for any evident non-compliance with rules of use, safety and protection. 
 

4.3 Assembly instructions 

 

GRY 15/20 HU (model without wheels) 

Before use, assemble the handle as follows: 
 

1

   

 

4

5

 

3

2

 

1)  Unscrew  the  four  screws  (1)  to 

remove the upper cover (2).  

2)    Align  handle  (3)  to  holes  on 

upper shell (2), fix handle using 
screws    (4)  and  nuts  (5) 
supplied with the unit.  

3)  Reassemble the upper shell (2).  
 

 

 

Содержание GRY-D 15 HU

Страница 1: ...rating Installation and Service Instructions Direct fired Diesel or Kerosene Heaters GRY D 15 HU GRY D 20 HU GRY D 20 WU GRY D 28 WU GRY D 40 WU GRY D 60 WU GRY I 15 WU GRY I 25 WU GRY I 40 WU GRY D GRY I ...

Страница 2: ..._________________________________________________________________________ 2 Index 1 General safety rules 2 Description of the appliance 3 Technical data 4 Installation instructions 5 Instructions for use 6 Maintenance 7 Troubleshooting ...

Страница 3: ...IN CARBON MONOXIDE A CHEMICAL KNOWN TO THE STATE OF CALIFORNIA TO CAUSE CANCER AND BIRTH DEFECTS OR OTHER REPRODUCTIVE HARM GENERAL HAZARD WARNING FAILURE TO COMPLY WITH THE PRECAUTIONS AND INSTRUCTIONS PROVIDED WITH THIS HEATER CAN RESULT IN DEATH SERIOUS BODILY INJURY AND PROPERTY LOSS OR DAMAGE FROM HAZARDS OF FIRE EXPLOSION BURN ASPHYXIATION CARBON MONOXIDE POISONING AND OR ELECTRICAL SHOCK ON...

Страница 4: ...r 1 6 HP 1 6 HP 1 6 HP 1 4 HP 1 3 HP 1 3 HP Current Rating A 1 8 2 0 2 0 3 5 4 0 4 2 Weight lb 41 44 57 68 81 84 Lenght in 32 32 33 34 37 42 Width in 14 14 17 19 22 22 Height in 16 16 18 21 24 25 Tank Capacity gal 5 6 5 6 5 6 8 12 12 Air Pressure Setting psi 4 1 4 5 4 5 4 8 5 8 4 9 3 2 Indirect fired heaters Model GRY I 15 WU GRY I 25 WU GRY I 40 WU Heat Input BTU hr 50 630 91 750 133 000 Air Flow...

Страница 5: ...and special fire safety regulations in force in all fields of applications must be followed In any case the following minimum safety clearances from materials or objects in the surroundings of the heater must be assured Side 2 ft 610 mm Air inlet side 2 ft 610 mm Top 5 ft 1525 mm Hot air outlet side 10 ft 3050 mm Floor 0 ft 0 mm Flue pipe 3 ft 915 mm Floors and ceilings must be made of fireproof m...

Страница 6: ...n axle ends by tapping lightly Connect the flue adaptor 11 to the exhaust collar and then to a flue pipe indirect fired heaters only Place heater on wheel support frame and line up holes on the fuel tank flange with holes on wheel support frame Insert screws and washers through handles fuel tank flange and wheel support frame Attach nut finger tight after each screw is inserted then tighten all nu...

Страница 7: ...trols the airflow pressure In the event of overheating the pressure switch shuts the heater down If this occurs detect and eliminate the cause of overheating before using the heater again Have the heater inspected by a qualified technician if required To reset let the unit cool unit down and then restart it as described above see par 5 2 5 4 Shut down Move switch to OFF O position DIRECT FIRED MOD...

Страница 8: ...g a light detergent and dry it thoroughly before reinstalling Replace air delivery filter 4 at least once a year Ignition Electrodes Clean adjust and if necessary replace ignition electrodes every 300 hours of functioning For electrode gap see illustration Pump Pressure Adjustment Remove pressure gauge cap from filter end cover Install a pressure gauge with a precision of at least 0 1 psi Start he...

Страница 9: ...minutes and restart the appliance If required clean replace air pressure switch Motor runs but the heater does not ignite and locks out after a short time Empty fuel tank dirty or wrong fuel Remove wrong or dirty fuel Fill the tank with clean oil or kerosene Fuel filter clogged Clean or replace fuel filter Air leaks in oil line Check pipes tighten connections if necessary replace Burner nozzle clo...

Страница 10: ... PA FC black N N L N N black green green FC Photocell FS Fuse IN Switch M Motor TR Transformer PA Air pressure switch GRY I 15 WU 25WU 40WU GRY D 60WU blue brown L N TR black black FS white white black M black EARTH TR SV PHOTO PHOTO MT INT 1 black black IN INT 2 P PA FC black N N L N N black EV Optional 2 3 1 TH green green brown TR Transformer FS TH IN M EV FC Air solenoid valve Remote thermosta...

Страница 11: ...__________________________________________________________________________________________________________ 11 ...

Страница 12: ...__________________________________________________________________________________________________________ 12 ...

Отзывы: