Munters GRY-D 15 HU Скачать руководство пользователя страница 4

__________________________________________________________________________________________________________ 

 

automatic cooling function (indirect-fired models and GRY-D 60) 

 
3. TECHNICAL SPECIFICATIONS 

 

3.1 Direct-fired heaters 

 

Model # 

GRY-D 

15 HU 

GRY-D 

20 HU 

GRY-D 

20 WU 

GRY-D 

28 WU 

GRY-D 

40 WU 

GRY-D 

60 WU 

Heat Input (BTU/hr) 

51,600 

80,500  

80,500  

101,260  

140,200 

211,000 

Air Flow Rating (ft³/min) 

210 

240 

240 

300 

620 

765 

Fuel Type 

Diesel  

Kerosene  

 #1-2 Fuel Oil 

Diesel  

Kerosene  #1-

2 Fuel Oil 

Diesel  

Kerosene  #1-

2 Fuel Oil 

Diesel  

Kerosene 

  #1-2 Fuel 

Oil 

Diesel  

Kerosene 

  #1-2 Fuel 

Oil 

Diesel  

Kerosene  

 #1-2 Fuel Oil 

Fuel Consumption (gal/hr) 

0.39 

0.58 

0.58 

0.73 

1.01 

1.51 

Fuel Nozzle Size 

0.40 gph 

0.65 gph 

0.65 gph 

0.75 gph 

1.00 gph 

1.50 gph 

Efficiency (%) 

(100) 

(100) 

(100) 

(100) 

(100) 

(100) 

Noise Level at 2m (dB(A)) 

69 

71 

71 

72 

75 

75 

Voltage (V) 

115V 60Hz 

115V 60Hz 

115V 60Hz 

115V 60Hz 

115V 60Hz 

115V 60Hz 

Electrical Power  

1/6 HP 

1/6 HP 

1/6 HP 

1/4 HP 

1/3 HP 

1/3 HP 

Current Rating (A) 

1.8 

2.0 

2.0 

3.5 

4.0 

4.2 

Weight (lb) 

41 

44 

57 

68 

81 

84 

Lenght  (in) 

32 

32 

33 

34 

37 

42 

Width (in) 

14 

14 

17 

19 

22 

22 

Height (in) 

16 

16 

18 

21 

24 

25 

Tank Capacity (gal) 

5.6 

5.6 

5.6 

12 

12 

Air Pressure Setting (psi) 

4.1 

4.5 

4.5 

4.8 

5.8 

4.9 

 

 

3.2 Indirect-fired heaters 

 

Model # 

GRY-I 
15 WU 

GRY-I 
25 WU 

GRY-I 
40 WU 

Heat Input (BTU/hr) 

50,630 

91,750 

133,000 

Air Flow Rating (ft³/min) 

412 

557 

710 

Fuel Type 

Diesel   

Kerosene 

#1-2 Fuel Oil 

Diesel  

Kerosene 

#1-2 Fuel Oil 

Diesel  

Kerosene 

#1-2 Fuel Oil 

Fuel Consumption (gal/hr) 

0.36 

0.66 

0.94 

Fuel Nozzle 

0.40 gph 

0.75 gph 

1.00 gph 

Efficiency (%) 

84.4 

80.0 

81.4 

Noise Level at 2m (dB(A)) 

63 

75 

75 

Voltage (V) 

115V 60Hz 

115V 60Hz 

115V 60Hz 

Electrical Power  

1/4 HP 

1/3 HP 

1/3 HP 

Current Rating (A) 

3.5 

4.0 

4.0 

Weight (lb) 

77 

88 

93 

Lenght (in) 

34 

37 

42 

Width (in) 

19 

22 

22 

Height (in) 

22 

25 

26 

Tank Capacity (gal) 

12 

12 

Air Pressure Setting (psi) 

4.4 

4.8 

4.9 

 

 

 
4. INSTALLATION INSTRUCTIONS 

 

4.1. General instructions 

 

 

THE INSTALLATION OF THE EQUIPMENT SHALL BE IN ACCORDANCE WITH THE REGULATION OF 

AUTHORITIES HAVING JURISDICTION AND CSA B139.  

Содержание GRY-D 15 HU

Страница 1: ...rating Installation and Service Instructions Direct fired Diesel or Kerosene Heaters GRY D 15 HU GRY D 20 HU GRY D 20 WU GRY D 28 WU GRY D 40 WU GRY D 60 WU GRY I 15 WU GRY I 25 WU GRY I 40 WU GRY D GRY I ...

Страница 2: ..._________________________________________________________________________ 2 Index 1 General safety rules 2 Description of the appliance 3 Technical data 4 Installation instructions 5 Instructions for use 6 Maintenance 7 Troubleshooting ...

Страница 3: ...IN CARBON MONOXIDE A CHEMICAL KNOWN TO THE STATE OF CALIFORNIA TO CAUSE CANCER AND BIRTH DEFECTS OR OTHER REPRODUCTIVE HARM GENERAL HAZARD WARNING FAILURE TO COMPLY WITH THE PRECAUTIONS AND INSTRUCTIONS PROVIDED WITH THIS HEATER CAN RESULT IN DEATH SERIOUS BODILY INJURY AND PROPERTY LOSS OR DAMAGE FROM HAZARDS OF FIRE EXPLOSION BURN ASPHYXIATION CARBON MONOXIDE POISONING AND OR ELECTRICAL SHOCK ON...

Страница 4: ...r 1 6 HP 1 6 HP 1 6 HP 1 4 HP 1 3 HP 1 3 HP Current Rating A 1 8 2 0 2 0 3 5 4 0 4 2 Weight lb 41 44 57 68 81 84 Lenght in 32 32 33 34 37 42 Width in 14 14 17 19 22 22 Height in 16 16 18 21 24 25 Tank Capacity gal 5 6 5 6 5 6 8 12 12 Air Pressure Setting psi 4 1 4 5 4 5 4 8 5 8 4 9 3 2 Indirect fired heaters Model GRY I 15 WU GRY I 25 WU GRY I 40 WU Heat Input BTU hr 50 630 91 750 133 000 Air Flow...

Страница 5: ...and special fire safety regulations in force in all fields of applications must be followed In any case the following minimum safety clearances from materials or objects in the surroundings of the heater must be assured Side 2 ft 610 mm Air inlet side 2 ft 610 mm Top 5 ft 1525 mm Hot air outlet side 10 ft 3050 mm Floor 0 ft 0 mm Flue pipe 3 ft 915 mm Floors and ceilings must be made of fireproof m...

Страница 6: ...n axle ends by tapping lightly Connect the flue adaptor 11 to the exhaust collar and then to a flue pipe indirect fired heaters only Place heater on wheel support frame and line up holes on the fuel tank flange with holes on wheel support frame Insert screws and washers through handles fuel tank flange and wheel support frame Attach nut finger tight after each screw is inserted then tighten all nu...

Страница 7: ...trols the airflow pressure In the event of overheating the pressure switch shuts the heater down If this occurs detect and eliminate the cause of overheating before using the heater again Have the heater inspected by a qualified technician if required To reset let the unit cool unit down and then restart it as described above see par 5 2 5 4 Shut down Move switch to OFF O position DIRECT FIRED MOD...

Страница 8: ...g a light detergent and dry it thoroughly before reinstalling Replace air delivery filter 4 at least once a year Ignition Electrodes Clean adjust and if necessary replace ignition electrodes every 300 hours of functioning For electrode gap see illustration Pump Pressure Adjustment Remove pressure gauge cap from filter end cover Install a pressure gauge with a precision of at least 0 1 psi Start he...

Страница 9: ...minutes and restart the appliance If required clean replace air pressure switch Motor runs but the heater does not ignite and locks out after a short time Empty fuel tank dirty or wrong fuel Remove wrong or dirty fuel Fill the tank with clean oil or kerosene Fuel filter clogged Clean or replace fuel filter Air leaks in oil line Check pipes tighten connections if necessary replace Burner nozzle clo...

Страница 10: ... PA FC black N N L N N black green green FC Photocell FS Fuse IN Switch M Motor TR Transformer PA Air pressure switch GRY I 15 WU 25WU 40WU GRY D 60WU blue brown L N TR black black FS white white black M black EARTH TR SV PHOTO PHOTO MT INT 1 black black IN INT 2 P PA FC black N N L N N black EV Optional 2 3 1 TH green green brown TR Transformer FS TH IN M EV FC Air solenoid valve Remote thermosta...

Страница 11: ...__________________________________________________________________________________________________________ 11 ...

Страница 12: ...__________________________________________________________________________________________________________ 12 ...

Отзывы: