25
|
© Munters AB, 2020
8.7 Fan bearing lubrication
Bearings are properly sized, with double sealed protection (2RS) and lubricated for life, therefore they do not require any
additional lubrication.
8.8 Replacement of shutter opening device (centrifugal system)
fig.28
1. open shutter by hand and take away the pin, which
connects central shutter blade to centrifugal system;
fig.29
2. unscrew the two M8 hexagonal socket head cap
screws and pull out the whole centrifugal system
through the shutter blades.
3. do the reverse procedure to replace the shutter
opening device and put back the pin, which
connects central shutter blade to centrifugal system.
WARNING
There are a number of steps that can greatly reduce or eliminate the white rust formation on the
tightly packed components of fans delivered unassembled:
•
keep the components dry;
•
unpack the components to permit air circulation between the surfaces;
•
stack the components to allow water to drain out;
•
keep the packed components in such way to prevent moisture contact with the Munters Protect coated surface.