Indoor Unit
Installation
Step 3: Drill wall hole for connective piping
1.
Determine the location of the wall hole based
on the position of the mounting plate. Refer
to
Mounting Plate Dimensions.
Wall
Indoor
Outdoor
m
m7
-
5 (0.2-0.275in)
Fig.3.2
MOUNTING PLATE DIMENSIONS
Different models have different mounting plates.
For the convenience of installation, there are
bubble level, carved dimensions on the
mounting plate. Please install the plate and drill
wall hole according to the information of the
mounting plate. See the figures below.
2.
Using a 65mm (2.5in) or 90mm (3.54in)
(depending on models) core drill, drill a
hole in the wall. Make sure that the hole
is drilled at a slight downward angle, so
that the outdoor end of the hole is lower
than the indoor end by about 5mm to
7mm (0.2-0.275in). This will ensure proper
water drainage.
3.
Place the protective wall cuff in the hole.
This protects the edges of the hole and
will help seal it when you finish the
installation process.
CAUTION
When drilling the wall hole, make sure
to
avoid wires, plumbing, and other
sensitive components.
Φ
NOTE:
When the gas side connective pipe is
16mm (5/8in) or more, the wall hole should
be 90mm (3.54in).
82
Correct orientation of Mounting Plate
Model 09
Left rear wall
hole 65mm (2.5in)
Right rear wall
hole 65mm (2.5in)
Indoor unit outline
722mm(28.5in)
179mm(7.1in)
348.4mm(13.7in)
290mm(11.4in)
49mm(1.95in)
37mm (1.45in)
49mm (1.95in)
101mm(4.0in)
136mm(5.4in)
Unit: mm (inch)
Содержание MUPR-09-H11
Страница 43: ...Manual del Control Remoto Control remoto Especificaciones del Control Remoto 43...
Страница 44: ...Control remoto Informaci n Previa a su Utilizaci n 44...
Страница 48: ...Control remoto 48...
Страница 49: ...Control remoto 49...
Страница 50: ...Control remoto 50...
Страница 52: ...Control remoto 52...
Страница 53: ...Control remoto Funci n Silence 53...
Страница 288: ...www mundoclima com C ROSSELL 430 432 08025 BARCELONA 34 93 446 27 80 SAT 34 93 652 53 57 ESPA A SPAIN...