Wall mounted FCU DC
Follow me function
Function instruction
This air conditioner has follow me function,
when this function is operated, the remote
controller will detect the temperature near the
remote controller and compare with the temperature you set
atuomatically, and controll the operation of the air conditioner
according to the contrastive result, and make the temperature
near the remote controller reaches the setting temperature.
This function is valid only under COOL, HEAT, AUTO mode
and the unit has follow me function.
The remote controller can not be placed near the heat source
or low temperatue source, otherwise will affect its tempera-
ture gathering precision and then affect the follow me
function.
DRY E
•A•H FOLLOW ME
Fig.5-4
Energy-saving function
Function instruction
Function instruction
Strong operation function
Lighting
Running
Turbo
TURBO
When operating cooling, press
the “TURBO” button and
operate the strong cooling
operation, at the same time raise the frequency,
press again will close the strong operation.
This function is invalid under operating sleep function.
When operating COOL/AUTO, press the “ECO” button, and
operate power save function; press again will cancel the
function.
Under the DRY/FAN mode, this function is invalid.
Under power save state, press “MODE”,”ON/OFF” or “FAN”
button will cancel this function.
Display function
Function instruction
For avoiding the display light of the indoor unit will affect
customer’s rest, this unit has special display funtion.
When the air conditioner is operated, press the “DISPLAY”
button, then can close(open) the module display,
press again can open (close) the display.
Function instruction
Press the “MODE” and “TIMER”button at the same time and
last over 5s, then can operate locking the remote controller.
In locked state, all the buttons are ineffective.
Press the “MODE” and “TIMER”button again at the same time
and last over 2s, then can close the locking.
Function instruction
Press “26°C” on the remote controller can operate
the cooling operationg mode with the setting
temperature of 26°C.
26°C green function
Lock function
Fig.5-5
Fig.5-6
Auto heat recycling mode function
CAUTION
5.4 Other functions operations only available when the indoor
unit has corresponding functions.
Example:
ΔT is 1°C, Ts is 25°C.
when Tf-Ts>=
ˇ
ΔT, it will operate COOL mode, the fan speed will be
operated according to the setting fan speed.
when Tf-Ts<=
ˉ
ΔT, it will operate HEAT mode, the fan speed will be
operated according to the setting fan speed.
Note
This function operations only available when the indoor
unit is
in the heat recycling three-pipe system
.
When the remote controller selects the auto heat recycling-
mode, the remote controller position must be placed at the signal
receiving range of the air conditioner.
When the remote controller detects changes of the mode(cool
to heat,or heat to cool), it will send the changes to air conditioner.
One beep of air conditioner changed mode signals is giving out.
Function
instruction
ΔT
˖
Temperature difference, means the different temperature
between the indoor temperature (Tf) detected by the remote
controller and the remote controller setting temperature (Ts).
(the default difference is 3°C, the difference range is 1~4°C)
SW1 definition
Auto Mode (Normal)
SW1
SW1
Auto heat recycling Mode
TEMP
SET
press and buttons for 5S simultaneously,
then enter ΔT setting state.
TEMP
SET
ON/OFF
FAN SPEED
FAN SPEED
ΔT setting state
press or button
adjust ΔT you want
press ON/OFF button
confirm and exit the setting
ΔT
instruction
TIMER
TIMER
Timing Setting
TIMER ON
TIMER ON
FAN SPEED
FAN SPEED
COOL
FAN SPEED
FAN SPEED
COOL
FAN SPEED
FAN SPEED
COOL
TIMER ON
Setting timing ON
Under the remote controller is OFF, press the “TIMER” button,
then the remote controller will display the timing ON icon and
number display area will show up last timing ON time, and will
display icon “h”. The remote controller enters to the timing ON
adjusting state.
(Continue) Press “TIMER” button, then can adjust the timing
ON time to what you want.
After adjustment, the remote controller transmit the timing ON
signal, and after 5s the icon “h” will be disappeared, and the
number display area will back to display temperature, then
finish the timing ON setting.
1.
2.
3.
Fig.5-7
2.4.5. Timer operation
25
Remote controller