background image

Wall mounted FCU DC

2. Wireless remote controller RM02A

The outline figure on cover is for reference only, 
which may differ from what you purchased.

Make sure to read chapter PRECAUTIONS 
before you operate the air conditioner.

This manual is available for model 
RM02A/BGE-A and RM02A/BGE(T)-A.

Model

Rated voltage

Effective receiving distance

Operation condition

3.0V(2 pieces of LR03 7# batteries)

RM02A/BGE-A  RM02A/BGE(T)-A

2.0V

8m(Where is 3.0V,that will be 11m

-5~60°C

Min voltage for sending 
signal of CPU 

ECONOMIC 
OPERATION

ON/OFF

ADJUST

TIMER

26°C

MODE

FAN 

SPEED

HORIZ  SWING

VERT SWING

Remote signal 
emission terminal

STRONG

DISPLAY

DRY·AUXILIARY HEAT

ј

FOLLOW ME

ON OFF

MODE

FAN

SPEED

TURBO

LED DISPLAY

TEMP

SET

TIMER

ECO

DRY E•A•H FOLLOW ME

FAN DIRECTION

RM02A/BGE-A

AUTO

COOL

DRY
HEAT
FAN

TIMER OFF

TIMER ON

FOLLOW ME

      TEMP

FAN SPEED

FAN SPEED

FOLLOW ME

FOLLOW ME

SLEEP

MODE

1

2

4

5

7

9

3

6

8

10

12

11

Fig.3-1

ś

26

°C: Press this button, can operate the cool mode with the 

     setting temperature 

26

°C

.

ŝ

TIMER

φ

Ś

ON/OFF: For turning on or turning off the air conditioner.

DRY

HEAT

FAN

AUTO

COOL

Ŝ

MODE: Once pressing, running mode will be selected in the 

      following sequence:

Under the OFF state, press this button, TIMER ON are ligtened. 

continue to press TIMER button, the time will increase by 0.5 

hour. When the set time exceeds 10 hours, pressing TIMER button 

will increase the time by 1 hour.Adjust the TIMER ON to be “0:00” 

then can cancel the TIMER ON.

Under the ON state, press this button, TIMER OFF are ligtened. 

and continue to press TIMER button, the time will increase by 0.5 

hour. When the set time exceeds 10 hours, pressing TIMER button 

will increase the time by 1 hour.Adjust the TIMER OFF to be “0:00” 

then can cancel the TIMER OFF.

2.1. Model and specification

2.2. Buttons and their functions

: Decrease the set temp. Keeping pressing will 
    decrease the temp with 1

ć

per 0.5s. 

Š

  

HORIZ SWING: Activate or turn off wind horizontal 

     swing function. (Only available when remote controller 
     is used with corresponding unit.) 

ADJUST   

ş

ADJUST

Ş

ECO: Activate or turn off economic operation mode. 

Increase the set temp. Keeping pressing will 
increase the temp with 1

ć

per 0.5s. 

AUTO → LOW → MED → HIGH

š

FAN SPEED: 

Fan speed will be selected in following sequence once 
pressing this button: (Under the DRY and AUTO mode (except 
for the auto heat recycling mode), the fan speed will be fixed 
and can not be adjusted. Under the auto heat recycling mode, 
the fan speed will be automatically and can be adjusted.)

Ţ

VERT SWING: Activate or turn off wind vertical swing 

     function. Under the power off state, this button will not work.
     (Only available when remote controller is used with 
     corresponding unit.)

ţ

STRONG

φ

Press this button, set the air conditioner to operate as strong 
mode, and the frequency will be raised, press again will cancel 
this mode. (Only available when remote controller is used with 
corresponding unit.)

DRY·AUXILIARY HEAT

ј

FOLLOW ME

˖

Press the left of the button when it is operating the dry cleaning 
function, will close the dry cleaning function; press the right of 
the button when it is operating follow me function, will close the 
follow me function.(Only available when remote controller is 
used with corresponding unit.)

11

DISPLAY

˖

When the air conditioner is on the ON state, press this button, 
can close (open) the modules display, press again will open 
(close) the display. (Only available when remote controller is 
used with corresponding unit.)

12

23

Remote controller

Содержание MUP-W7

Страница 1: ...English CL04315 to CL04318 Wall Mounted FCU DC www mundoclima com www mundoclima com MUP W7 Installation and Owner s manual and Information requirements...

Страница 2: ...be used for hosehold use The power supply must be SINGLE PHASE one phase L and one neutral N with his grounded power GND switch Any breach of these specifications involve a breach of the warranty con...

Страница 3: ...entative care on your part can save you a great deal of time and money over the life of your air conditioner You ll find manyanswers to common problems in the chart of troubleshooting tips If you revi...

Страница 4: ...e the single outlet with other electrical appliances Otherwise it will cause fire or electrical shock Be sure to be in conformity with the local national and international laws and regulations Read PR...

Страница 5: ...til w including iring and piping the air conditioner is done While following the instructions in this installation manual install drain piping in order to ensure proper drainage and insulate piping in...

Страница 6: ...ve and negative poles are right positions when loading batteries This manual is subject to changes due to technological improvement without further notices Cautions on remote controller installation R...

Страница 7: ...ntal and its structure can endure the weight of the indoor unit The outlet and the inlet are not impeded and the influence of external air is the least The air flow can reach throughout the room The c...

Страница 8: ...en the outdoor unit and bend and arrange the pipe carefully Be careful not to let the drain hose slack Insulate both of the auxiliary piping 43 Indoor unit outline Connective pipe 2 Drilling a hole De...

Страница 9: ...Unit from side to side up and down to check if it is hooked securely Because the condensed water from rear of the indoor unit is gathered in Pond Box and is piped out of room Do not put anything else...

Страница 10: ...Fig 7 2 NOTE 7 1 Terminal Board Diagram Please refer to the indoor unit wiring diagram for the wiring The air conditioners can connect with Central Control Monitor CCM Before operation please wiring c...

Страница 11: ...ative care on your part can save you a great deal of time and money over the life of your air conditioner You ll find manyanswers to common problems in the chart of troubleshooting tips If you review...

Страница 12: ...l Air inlet Air outlet Inlet pipe Return pipe Drain pipe 1 2 3 4 5 Bottom plate Remote controller Faceplate Display panel Horizontal air deflector 1 2 3 4 5 3 Display panel Infrared signal receiver Op...

Страница 13: ...d by yourself may result in a water leakage electric shock and fire Ask your dealer for improvement repair and maintenance Incomplete improvement repair and maintenance may result in a water leakage e...

Страница 14: ...is product as unsor ted municipal waste Collection of such waste sepa rately for special treatment is necessary Do not dispose of electrical appliances as unsorted municipal waste use separate collect...

Страница 15: ...h to wipe the indoor unit and remote controller A wet cloth may be used to clean the indoor unit if it is very dirty Never use a damp cloth on the remote controller Do not use a chemically treted dust...

Страница 16: ...eating model When just starting if the compressor has not started the indoor unit appears anti cold wind protection because of its overlow outlet temperature In order to prevent the indoor evaporator...

Страница 17: ...nate all dirties and make air smooth Close doors and windows Make curtains in order to shelter from sunshine Reduce heat source AC cooling capacity reduces normal Symptoms Causes Unit does not start A...

Страница 18: ...nd then repeatly push the ON OFF button twice The indication on the display disappears after a lapse of time Check whether the timer operation has come to an end when the TIMER OFF is indicated on the...

Страница 19: ...REMOTE CONTROLLER Please read this manual carefully before installing and using the unit 19...

Страница 20: ...or or the like objects will prevent the remote signal from being received by air conditioner Do not get the interior of remote controller wet It is forbidden to expose it to direct sunlight or locate...

Страница 21: ...urrent setting and reset remote controller LOCK inner located Press this button with a needle of 1mm to lock or unlock the current setting OK Used to confirm the time setting and modification COOL HEA...

Страница 22: ...adjust the time 3 Keep pressing this button the time will increase by 0 5 hour When the set time exceeds 10 hours pressing the button will increase the time by 1 hour 4 0 5s after setting remote contr...

Страница 23: ...essing TIMER button will increase the time by 1 hour Adjust the TIMER OFF to be 0 00 then can cancel the TIMER OFF 2 1 Model and specification 2 2 Buttons and their functions Decrease the set temp Kee...

Страница 24: ...OFF TIMER ON FOLLOWME TEMP FAN SPEED FAN SPEED FOLLOW ME FOLLOW ME SLEEP MODE ON OFF Lock Timer ON OFF Running mode Temperature Fan speed Transmitting display Follow Me Transmitting display The icon...

Страница 25: ...tting temperature of 26 C 26 C green function Lock function Fig 5 5 Fig 5 6 Auto heat recycling mode function CAUTION 5 4 Other functions operations only available when the indoor unit has correspondi...

Страница 26: ...ON only can set timing OFF under the remote controller is OFF only can set timing ON Precautions Curtain door or the like objects will prevent the remote signal from being received by air conditioner...

Страница 27: ...Wall mounted FCU DC Q Q Q and and cancel timer on and timer off Q state 27 Remote controller...

Страница 28: ...Wall mounted FCU DC turn on or turn off th e auto sw ing function room temperature read from th e local sensor and 28 Remote controller...

Страница 29: ...1 0 2 45 0 9 1 0 1 0 00 5 0 1 2 3 45 0 1 3 45 6 0 1 7 33 45 8 1 0 9 1 0 2 45 0 9 1 0 1 0 00 5 0 1 3 45 0 1 3 45 6 0 1 7 233 45 8 1 0 9 1 0 45 0 9 1 0 1 0 00 5 2 0 1 3 45 0 1 2 3 45 6 0 1 7 33 45 8 1 0...

Страница 30: ...ASK FOR MORE INFORMATION Phone 34 93 446 27 81 eMail info mundoclima com TECHNICAL ASSISTANCE Phone 34 93 652 53 57 www mundoclima com...

Отзывы: