WIRED CONTROLLER
Fig 3-2
}!^ !\ !
Insert a slot screwdriver into the slots in the lower
part of the wire controller (2 places), and remove
the upper part of the wire controller. (Fig.3-2)
@!
NOTICE
The PCB is mounted in the upper part of the wire
controller. Be careful not to damage the board
with the slot screwdriver.
Fig 3-3
For exposed mounting, fasten the back plate on the wall with the 3 screws (M4×20)
and plugs. (Fig.3-3)
!!^!!^\ !
Back plate
Screws (M4×20)
Fig 3-4
@\!^_
!
For flush-mounting, fasten the back plate on the switch box with 2 screws (M4×25) and
fasten it on the wall with 1 screw (M4×20). (Fig.3-4)
Screw (M4×20)
Screws (M4×25)
NOTICE
Put on a flat surface. Be careful not to distort the back plate of the wire controller
by overtightening the mounting screws.
Put the battery into the installationsite and make sure the positive side of the battery
is in accordance with the positive side of installationsite.(See Fig.3-5)
Please set the time corrected on the first time operation. Batteries in the wire
controller can timing under power failure which ensure the time keep right. When
the power restores, if the time displayed is not correct, it means the battery is dead
and replace the battery.
Fig 3-5
4. Battery installation
91
Содержание MUCR-12-H8
Страница 289: ...289 ...
Страница 290: ...www mundoclima com C PROVENZA 392 P2 08025 BARCELONA SPAIN 34 93 446 27 80 ...