CLOCK display 

Usually display the clock set currently. Press the button CLOCK for 4 seconds, 
the  HOUR part will flash, press button     

and    to adjust HOUR. Press the button 

CLOCK again, the minute part flash, press button     or     to adjust MINUTE. 
After clock set or clock operation, it must  press CONFIRM to complete the set. 

 TIMER ON/OFF display:  

Display ON at the state of TIMER ON  adjustment or after only set the TIMER 

ON; Display OFF at the state of TIMER  OFF adjustment or after only set the 
TIMER OFF; Display ON/OFF if simulta neously set the mode of TIMER ON and 

TIMER OFF. 

 Temperature display area:  

Usually display the set temperature.  Press the buttons of  and to set tempera
ture, at the mode of FAN, there is no  figure display in the area. 

5. INSTALLATION METHOD 

5-Core Shield Cable,the length 
is decided by installation 

Wire Joint, 5p

Infraed Pipe

Indoor Unit

RUN

+5V

Indoor Unit Switch Board

Wire Controller

Connection mothod and the principle 
diagram show as follow

When the air conditioner needs installing the wire controller, an additional 5-terminal is 
needed to install in indoor unit, fasten a infrared emission (fasten with glue), connect the 
anode and the cathode respectively to A and B on the end, then connect the +5V GND 
and RUN respectively to C D and E on the end 

Installation interpretation:

Economical operation display: 

Press ECONOMICAL to display econo mical operation, if press ECONOMICAL 

again then the display disappears 

Lock display  Press  LOCK to display the icon of  LOCK. Press the button

again then the icon of LOCK disappears. In the mode of   LOCK, all the buttons

 are invalid except  for LOCK button. 

Содержание KJR-10B/DP(T)-E

Страница 1: ...2B DP T E Para una correcta instalaci n leer este manual antes de iniciar la instalaci n Este manual puede estar sujeto a cambios sin notificaci n alguna con intenci n de mejora MANUAL DE USUARIO MAND...

Страница 2: ......

Страница 3: ...S INDICADORES DEL MANDO 5 M TODO DE INSTALACION 6 NOMBRE Y FUNCION DE LOS BOTONES DEL MANDO 7 MODOS DE USO a FUNCIONAMIENTO AUTOMATICO b FRIO CALOR VENTILACION c DESHUMIDIFICACION d TEMPORIZADOR e PAR...

Страница 4: ...1 PRECAUCIONES DE SEGURIDAD...

Страница 5: ...SHUM HEAT CALOR FAN VENTILACION AUTO 2 Temporizador Cuando se programa la hora de encendido o cuando durante el periodo de encendido la se al ON se muestra en la pantalla Cuando se selecciona la hora...

Страница 6: ...lta 6 Bloqueo LOCK Cuando el bot n LOCK se pulsa el s mbolo de bloqueado aparece en la pantalla y el resto de botones no est n disponibles pulsando otra vez el icono desaparece 7 Temperatura Muestra l...

Страница 7: ...r a 0 0 4 FOLLOW ME En modo refrigeracion calefacci n o auto pulse este boton para activar la funci n follow me Pulse de nuevo para cancelar dicha funci n 5 RESISTENCIA ELECTRICA Pulse este boton para...

Страница 8: ...entilaci n Pulse este boton para cambiar la velocidad de ventilaci n como sigue a AUTO BAJO MEDIO ALTO 13 Boton LOCK Escondido Cuando se pulsa este boton el mando se queda bloqueado y no pueden cambia...

Страница 9: ...R S MANUAL WIRE CONTROLLER OF AIR CONDITIONER MODEL KJR 10B DP T E Thank you very much for purchasing our product Before using your unit please read this manual carefully and keep it for future refere...

Страница 10: ......

Страница 11: ...TTING ONLY SET THE TIME OF TIMER ON ONLY SET THE TIME OF TIMER OFF SET THE TIME OF TIMER ON AND TIMER OFF SIMULTANEOUSLY 8 TECHNIQUE CERTIFICATION AND REQUIREMENT This manual gives detailed descriptio...

Страница 12: ...of properties and materials W W arning arning Caution Icon description Meaning lcon It indicates forbidding The forbidden subject matter is indicated in the icon or by images or characters aside Warn...

Страница 13: ...erature display OFF ON display LOCK display CLOCK display Economical operation display FAN speed MODE display 2 WIRE CONTROLLERSUMMARIZE 3 FUNCTION SUMMARIZE The basic operation conditions of wire con...

Страница 14: ...figure display in the area 5 INSTALLATION METHOD 5 Core Shield Cable the length is decided by installation Wire Joint 5p Infraed Pipe Indoor Unit RUN 5V Indoor Unit Switch Board Wire Controller Conne...

Страница 15: ...he time moves forward by o 5 hours When the set time is over 10 hours each time you push the button the time moves forward by 1 hour If want to cancel the TIMER ON then adjust the time of TIMER ON as...

Страница 16: ...W MED and HIGH Each time push the button the fan speed will change in turn as fellow Adjust button Set indoor temperature up If press and hold on it will increase at 1 degree per 0 5 second Adjust but...

Страница 17: ...lights the air conditioner operates according to the mode selected Push the button ON OFF again stop the air conditioner Remark It can not set temperature at FAN mode and only operate the step 1 3 an...

Страница 18: ...MR should conform to the CE certification Remark the time of TIMER ON is the relative time it is relative to the standard time of operating wire control ler If having setting the TIMER ON or TIMER OFF...

Страница 19: ......

Страница 20: ...SALVADOR ESCODA S A www salvadorescoda com Proven a 392 pl 1 y 2 08025 Barcelona Tel 93 446 27 80 Fax 93 456 90 32...

Отзывы: