background image

 

  Safety Information

 

Please  read  this  manual  carefully  before  use  this  unit,  and  operate  it  correctly 

according to the guide in this manual. 

Please take specially note to the meaning of these two marks

 

Warning! 

This  mark  means  that  it  may  cause  casualty  or  badly  hurt  if  the 

operation is incorrect. 

Caution!

  This  mark  means  that  it  may  cause  casualty  or  property  loss  if  the 

operation is incorrect. 

Warning!   

  For  the  usage  safety  of  the  air  conditioner,  the  units  should  be  earthed 

reliably .Do not connect the earth line with the gas pipe,  water pipe, drainage pipe or 

other places that specialized personnel considers unsafe. 

  Air conditioner must use special power supply circuit and switches for creepage 

protect and air with enough capacity should be installed in the circuit. 

  Ensure that the connecting of power cord is normal, otherwise, electric shock or 

fire may happened. 

  Do not cut off the power supply to turn off the unit when it is running, otherwise 

life time of units may shortened.   

  Do not mangle wire or adopts wires that are not recommend to use, otherwise, 

electric shock or fire may happened. 

 

Please don’t operate the unit by wet hand, or electric shock may happened. 

 

Don’t insert finger or stick like things into outlet vent, otherwise, damage may 

be happened. 

  Cut down the main power switch immediately if malfunction (such as smell the 

burning odor etc.) happen, and then contact the special engaged maintenance center. 

If the abnormal state is maintained, the unit may be damaged or electric shock or fire 

may be happened. 

  Do  not  refit  the  conditioner.  Please  contact  the  agency  or  professional 

personnel to repair or move the conditioner. 

  Do not adopt fuse with unsuitable capacity or adopt iron thread instead of fuse, 

otherwise malfunction or fire may happened. 

  Do cut off the main power supply of air conditioner if it would not be used for a 

long time. 

Содержание CL 20 810

Страница 1: ...MULTISPLIT CEILING FLOOR H3M Installation and user s manual MUSTR H3M English CL20830 to CL20833 www mundoclima com...

Страница 2: ...nit will stop At this time change the operation mode of the indoor unit to the one that would not clash with the outdoor operating mode to make the operation normal The cooling mode is not clash with...

Страница 3: ...damaged it must be replaced by the manufacturer its service agent or similarly qualified persons in order to avoid a hazard Correct Disposal of this product This marking indicates that this product s...

Страница 4: ...ELECTRICAL WIRING 7 5 INSTALL THE DRAINAGE PIPE 9 6 INSTALL THE CONNECTION PIPES 10 CONSTITUTES AND NAMES OF EVERY PART OF FLOOR AND CEILING TYPE INDOOR UNIT 11 WORKING TEMPERATURE RANGE 12 MAINTENAN...

Страница 5: ...erwise electric shock or fire may happened Do not cut off the power supply to turn off the unit when it is running otherwise life time of units may shortened Do not mangle wire or adopts wires that ar...

Страница 6: ...ner otherwise electric shock or harm may be happened Chemical sprayer should be placed 1m or more away from the unit otherwise fire or explode may be caused Do not let blockage happened in the inlet o...

Страница 7: ...oom Such a place where is condensation water is easily drained out Such a place that can handle the weight of indoor unit Such a place which has easy access for maintenance Such a place where is permi...

Страница 8: ...not special nominated by Mundoclima would not deal with on time by the inconvenience of the business contact b It should be done by professional personnel when the air conditioner unit is moved to oth...

Страница 9: ...the unit to the ceiling slab beforehand Refer to Fig 4 d Fix the hanger bracket to the suspension bolt Warning Make sure that extended suspension bolt from the ceiling stays inside the arrowed positio...

Страница 10: ...unit Refer to Fig 9 Be sure to use only the specified accessories and parts for installation work When installing the indoor unit you can refer the paper pattern for installation and make sure that th...

Страница 11: ...ng hole of the chassis and the bottom of the appliance upward then connect the brown wire to the Terminal board 3 black wire the communication wire to the Terminal board 2 blue wire to the Terminal bo...

Страница 12: ...8 MUEX 42 H3 5...

Страница 13: ...reater than the diameter of the connecting pipe Keep the drain pipe short and incline downwards at a gradient of at least 1 100 to prevent air pockets Refer to Fig 10 Use the attached drain hose and c...

Страница 14: ...e tie the nut on tie in of the connect pipe tightly Caution Be careful in bending the connection pipes or you will damage the pipes If the tightening torque is too great in tightening the flare nut le...

Страница 15: ...tes and Names of Every Part of Floor And Ceiling Type Indoor Unit Suitable model Note The appearances will be same by the different models of air conditioners MUSTR 09 H3M MUSTR 12 H3M MUSTR 18 H3M MU...

Страница 16: ...conditioner wet or electric shock may be lead Ensure that the air conditioner will not be cleaned by water rinsing under any circumstance Volatility liquid like thinner or gasoline would damage the ap...

Страница 17: ...stall well by professional In order to start up the air conditioner smoothly after long time s turned off turn on the main power supply 8 hours before turning on the air conditioner Notice all above s...

Страница 18: ...14 Operating Instructions...

Страница 19: ...15...

Страница 20: ...er run The grating sound caused by expands of panel and other parts for the change of temperature The air conditioner cannot run Is power cut Is the power supply connected Is the circuit protector sta...

Страница 21: ...problems when purchasing air conditioner please contact the local electrify could resume normal operation re Is the controller within the receiving area Or is there blockage Check if the voltages of b...

Страница 22: ...e unit will keep the original running status 1 Function of Press Buttons Fig 17 1 ON OFF Press this button to turn on off the unit After that the sleep function will be canceled but the preset time is...

Страница 23: ...ght On and Light Off can be set by pressing this button when the unit is at On or Off status After powered on the default is Light On 7 TURBO In Cool or Heat mode pressing this button can activate or...

Страница 24: ...sed by 1 minute If the button is pressed down for more than 2 seconds the time will be changed quickly in such a way firstly the value on the one s place is changed and then is the value on the ten s...

Страница 25: ...ll be stopped completely b About AFTERHEAT X FAN Under the Heat mode or Auto Heat mode if the unit is turned off the compressor and outdoor fan will stop running immediately and the upper and lower gu...

Страница 26: ...ASK FOR MORE INFORMATION Phone 34 93 446 27 80 eMail info mundoclima com TECHNICAL ASSISTANCE Phone 34 93 652 53 57 www mundoclima com...