21
Install the rear panel
1.Always mount the rear panel horizontally.
2.Fix the rear panel on the selected location with
screws supplied.
3.Be sure that the rear panel has been fixed firmly
enough to withstand the weight of an adult of
60kg, furthermore, the weight should be evenly
shared by each screw.
Install the drain hose
1.For well draining, the drain hose should be
placed at a downward slant.
2.Do not wrench or bend the drain hose or flood
its end by water.
Install the piping hole
1.Make the piping hole ( 65) in the wall at a
slight downward slant to the outdoor side.The
center of the hole should be determined refer to
Fig.2.
2.Insert the piping - hole sleeve into the hole to
prevent the connection piping and wiring from
being damaged when passing through the hole.
Electrical wiring
1. Open the surface panel.
2. Remove the wiring cover.
3. Route the power connection cord from the back of the indoor unit and pull it toward the front throught the wiring
hole for connection.
4. Connect the blue wire of the power connection cord to the terminal “ N(1)”,the brown one to“ 2”, the red one to“ 3”,
and the yellow- green one ( earth wire ) to “ ’’ as shown in Fig.3.
5. Reassemble the wiring cover.
6.Recover the surface panel.
Wrenched
Bent
Flooded
NOTE:
Connect the connection pipes with the indoor unit firstly and the outdoor unit secondly.
Be careful in bending the connection pipes, or you will damage the pipes.
If the tightening torque is too great in tightening the flare nuts, leakage will happen.
Install the indoor unit
Install the connection pipes
Connect the connection pipes with the relevant union pipes of the indoor unit (Shown in P27
=
Pipe connection” )