Be  sure  to  be  in  conformity  with  the  local,  national  and 
international laws and regulations.

Read "PRECAUTIONS" carefully before installation.

The  following  precautions  include  important  safty  items. 
Observe them and never forget.

Keep this manual  in a handy place for future reference.

Before  out  from  factory,  FAN  COIL  UNIT  (AIR  UNITS)  has 
passed  Fan  Coil  Overpressure  Resistant  Test,  Statically 
and  Dynamically  Balanced  Adjustment,  Noise  Test,  Air 
(cool)  Volume  Test,  Electric  Property  Test,  Outline  Quality 
Detection. 

This appliance can be used by children aged from 8 years 
and  above  and  persons  with  reduced  physical,  sensory  or 
mental  capabilities  or  lack  of  experience  and  knowledge  if 
they  have  been  given  supervision  or  instruction 
concerning  use  of  the  appliance  in  a  safe  way  and 
understand  the  hazards  involved.  Children  shall  not  play 
with  the  appliance.  Cleaning  and  user  maintenance  shall 
not be made by children without supervision.

1.   PRECAUTIONS 

The safety precautions listed here are divided into two categories. In 
either case, important safety information is listed which must be read 
carefully. 

WARNING 

After  completing  the  installation,  make  sure  that  the  unit  operates 
properly  during  the  start-up  operation.  Please  instruct  the  customer 
on how to operate the unit and keep it maintained.

Be  sure  only  trained  and  qualified  service  personnel  to 
install, repair or service the equipment. 

Improper  installation,  repair,  and  maintenance  may  result  in 
electric  shocks,  short-circuit,  leaks,  fire  or  other  damage  to 
the equipment. 

Failure to observe a warning may result in death.

Failure  to  observe  a  caution  may  result  in  injury  or 
damage to the equipment.

CAUTION 

WARNING 

Install according to this installation instructions strictly. 

 

If  installation  is  defective,  it  will  cause  water  leakage, 
electrical shock and fire. 
 

When  installing  the  unit  in  a  small  room,  take  measures 
against to keep refrigerant concentration from exceeding 
allowable safety limits in the event of refrigerant leakage.

 

Contact  the  place  of  purchase  for  more  information. 
Excessive refrigerant in a closed ambient can lead to oxygen 
deficiency.

 

 

Use  the  attached  accessories  parts  and  specified  parts 
for installation. 

 

otherwise,  it  will  cause  the  set  to  fall,  water    leakage, 
electrical shock and fire. 
 

The appliance must be installed 2.3m above floor. 
 
The appliance shall not be installed in the laundry. 
 
Before  obtaining  access  to  terminals,  all  supply  circuits 
must be disconnected. 
 
The  appliance  must  be  positioned  so  that  the  plug  is 
accessible. 
 
The enclosure of the appliance shall be marked by word, 
or by symbols, with the direction of the fluid flow. 

 

For  electrical  work,  follow  the  local  national  wiring 
standard, regulation and this installation instructions. An 
independent circuit and single outlet must be used. 

 

If  electrical  circuit  capacity  is  not  enough  or  defect  in 
electrical work, it will cause electrical shock fire. 
 

Use  the  specified  cable  and  connect  tightly  and  clamp 
the  cable  so  that  no  external  force  will  be  acted  on  the 
terminal.

  

If  connection  or  fixing  is  not  perfect,  it  will  cause  heat-up  or 
fire at the connection. 

 
Wiring routing must be properly arranged so that control 
board cover is fixed properly. 

 

If  control  board  cover  is  not  fixed  perfectly,  it  will  cause 
heat-up  at  connection  point  of  terminal,  fire  or  electrical 
shock. 
 

If the supply cord is damaged, it must be replaced by the 
manufacture  or  its  service  agent  or  a  similarly  qualified 
person in order to avoid a hazard. 
 
An  all-pole  disconnection  switch  having  a  contact 
separation  of  at  least  3mm  in  all  poles  should  be 
connected in fixed wiring. 
 
When carrying out piping connection, take care not to let 
air substances go into refrigeration cycle. 

 

Otherwise,  it  will  cause  lower  capacity,  abnormal  high 
pressure in the refrigeration cycle. 
 

Do not modify the length of the power supply cord or use 
of extension cord, and do not share the single outlet with 
other electrical appliances. 

 

Otherwise, it will cause fire or electrical shock. 
 

If the water leaks during installation, ventilate the area 
immediately. 
 
After completing the installation work, check that the 
water does not leak. 
 

The cool water in the unit is not lower than 3

ć

, hot water is 

not higher than 65

ć

. Water in the unit must clean, air quality 

must meet to the standard of PH=6.5~7.5.

   

Installation manual

Universal FCU DC

3

7

Содержание MUC-W7/CE

Страница 1: ...English www mundoclima com www mundoclima com Universal FCU DC Installation manual MUC W7 CL04580 to CL04594 MUC W7 CE MUC W7 SE...

Страница 2: ...INGLE PHASE one phase L and one neutral N with his grounded power GND switch Any breach of these specifications involve a breach of the warranty conditions provided by the manufacturer In line with th...

Страница 3: ...lace of purchase for more information Excessive refrigerant in a closed ambient can lead to oxygen deficiency Use the attached accessories parts and specified parts for installation otherwise it will...

Страница 4: ...cks Be sure to install an earth leakage breaker Failure to install an earth leakage breaker may result in electric shocks Connect the outdoor unit wires then connect the indoor unit wires You are not...

Страница 5: ...ction as a ceiling mounted air handling terminal supplied through ducting or panelling any other use is expressly prohibited Installation of the machine in an explosive environment is also forbidden C...

Страница 6: ...sable to run the unit at maximum speed for several hours To ensure correct air intake the air filter must be cleaned at least once a month or more frequently if the unit is being used in very dusty en...

Страница 7: ...lectrical components Also make sure that there are no obstacles or people along the route to avoid the danger of collisions or crushing and to prevent the lifting or handling device from turning over...

Страница 8: ...at the time of installation For installation follow the instructions set out below Remove the external casing in versions CE and SE unscrewing the screws which secure it to the structure as following...

Страница 9: ...10 mm thick or install the auxiliary drain Pour water into the condensation collector tray and check that the liquid drains properly following it right through to the exit of the draintube If it does...

Страница 10: ...ecting cables and strip only the length of cable needed to go into the connector block In the event that the unit is mounted on a metal surface earth connections must be made in compliance with local...

Страница 11: ...no obstructions in the condensation drain tube which could prevent the normal flow of water 1 2 4 3 remove the casing of the machine start the system and run for a few minutes stop the system slacken...

Страница 12: ...procedures The unit should only be dismantled by a firm authorized for the disposal of scrap machinery The unit as a whole is composed of materials considered as secondary raw materials and the follo...

Страница 13: ...00 1200 900 700 500 D mm 1226 1226 926 726 526 Installation manual Universal FCU DC Model MUC 07 W7 CE MUC 11 W7 CE MUC 16 W7 CE MUC 19 W7 CE MUC 24 W7 CE 13 220 Rear view 105 46 D C 150 150 220 592 1...

Страница 14: ...E A C 212 87 Water connection Rear view 46 105 203 291 185 258 Fig 4 6 Fig 4 7 Fig 4 8 A mm B mm C mm D mm Model MUC 07 W7 SE MUC 11 W7 SE MUC 16 W7 SE MUC 19 W7 SE MUC 24 W7 SE 550 526 500 532 750 72...

Страница 15: ...0 471 V F Hz 220 240 1 50 220 240 1 50 220 240 1 50 220 240 1 50 220 240 1 50 W 16 33 29 39 116 MPa 1 6 1 6 1 6 1 6 1 6 C 65 65 65 65 65 inch 3 4 3 4 3 4 3 4 3 4 mm 16 16 16 16 16 Version SE W x H x...

Страница 16: ...ASK FOR MORE INFORMATION Phone 34 93 446 27 81 eMail info mundoclima com TECHNICAL ASSISTANCE Phone 34 93 652 53 57 www mundoclima com...

Отзывы: